Abstract
BACKGROUND: Unidirectional breathing (UB), nose-in mouth-out (NMB) or vice versa, is thought to create PEEP, stabilize small airways, and increase expiratory flow and exhaled tidal volume (VT) in patients with expiratory obstructive disorders. However, the exact mechanism providing the benefits of UB remains unknown. Our hypothesis was that the benefits of UB are achieved mainly through reduction of upper airway dead space.
METHODS: Sixteen stable COPD patients requiring oxygen use at home were enrolled in this prospective study at a tertiary health care center. A nasal mask and a mouthpiece were used, each having a removable one-way valve to direct the breathing pattern. Four experimentally defined patterns of spontaneous breathing, NMB, mouth-in nose-out (MNB), nose-in nose-out (NNB), and mouth-in mouth-out (MMB), were compared. Each breathing pattern lasted 5 min followed by a 5-min rest period. A NICO device continuously monitored respiratory parameters. The functional anatomical dead space volume (VD) and expired VT values were determined. Breathing efficiency (BE) was calculated as alveolar VT divided by expired volume.
RESULTS: Functional anatomical VD was higher in bidirectional breathing (BB) (overall: 207.4 ± 7.9 mL; MMB: 232.5 ± 72.7 mL; NNB: 182.2 ± 75 mL) compared to UB (overall: 178.1 ± 87.2 mL; NMB: 176.9 ± 91.3 mL; MNB: 179.3 ± 83.2 mL) (P < .001). BE achieved with UB (overall: 76.2 ± 6.5%; NMB: 76.8 ± 6.8%; MNB: 75.6 ± 6.3%) was higher than that with BB (overall: 66.2 ± 0.09%; MMB: 64.3 ± 0.10%; NNB: 68.1 ± 0.08%) (P < .001). The difference in BE between UB and BB was more pronounced with small VT values (UB: 73.8 ± 0.08; BB: 49.4 ± 0.09) than with large VT values (UB: 77.3 ± 0.06; BB: 63.0 ± 0.07) (P < .001).
CONCLUSIONS: Our data suggest that a reduction in functional anatomic VD may be the underlying mechanism for the benefits associated with UB in COPD patients. (ClinicalTrials.gov registration NCT00784004.)
Footnotes
- Correspondence: Robert M Kacmarek PhD RRT FAARC, Massachusetts General Hospital, 55 Fruit Street, Warren 1225, Boston, MA 02114. E-mail: rkacmarek{at}partners.org.
Drs Jiang and Kacmarek have patented a device that assists in assuring unidirectional breathing. However, this device has not been developed for manufacture or licensed to any company. Dr Kacmarek has received research grants from Covidien and Hollister and an honorarium for lecturing from Maquet and is a consultant for Covidien.
- Copyright © 2014 by Daedalus Enterprises