TY - JOUR T1 - Comparison of Two Assessment Tools for Hospitalized Subjects With Asthma JF - Respiratory Care SP - 104 LP - 112 DO - 10.4187/respcare.07761 VL - 66 IS - 1 AU - Sangeeta K Schroeder AU - Waheeda Samady AU - Irini N Kolaitis AU - Craig M Smith AU - Hannah Palac AU - Laura Shreffler AU - Mary A Nevin Y1 - 2021/01/01 UR - http://rc.rcjournal.com/content/66/1/104.abstract N2 - BACKGROUND: Pediatric Asthma Assessment tools used to guide the weaning of inhaled therapies during inpatient hospitalization require further evaluation and validation. This study aimed to compare 2 asthma assessment tools: an asthma scale versus an asthma score.METHODS: A prospective, physician-blinded, comparison study was conducted in 2 separate 6-week phases of patients > 2 y old admitted to a tertiary care children's hospital with status asthmaticus between July and November 2014. The asthma scale categorized 5 components (oxygen, auscultation, dyspnea, breathing frequency, and pulse oximetry) into 1 of 3 respiratory assessments: mild, moderate, or severe. The asthma score used a sum of the components, resulting in a score of 1–15. Study tool predictability was measured using a metric based on hours on continuous albuterol, with area under the curve ≥ 0.8 indicating good predictability. Agreement between clinicians was measured using the Cohen kappa statistic. Study tool clinical correlation was measured using Spearman coefficient. Usability was evaluated using web-based surveys.RESULTS: Phase 1 included 1,971 assessments (97 unique subjects), whereas phase 2 included 607 assessments (69 unique subjects). Using the continuous albuterol metric, predictability of the asthma scale had an area under the curve of 0.62 versus the asthma score area under the curve of 0.80. Agreement early in hospitalization for the asthma scale was kappa = 0.34 (95% CI 0.18–0.5; n = 84) versus kappa = 0.55 (95% CI 0.35–0.76; n = 44) for the asthma score. Agreement late in hospitalization for the asthma scale was kappa = 0.38 (95% CI 0.17–0.59; n = 66) versus kappa = 0.41 (95% CI 0.13–0.69; n = 33) for the asthma score. Clinical correlation for the asthma scale (no. = 1,908) was r = 0.57 (P < .001) versus r = 0.80 (P < .001) for the asthma score (no. = 558). Mean asthma scale usability was 3.38 versus 3.68 for the asthma score.CONCLUSIONS: The asthma score showed better clinical predictability and clinical correlation compared to the asthma scale. Numerical scores provided more objective assessments compared to categorical scores. Validated scoring tools such as the asthma score are crucial to the success of management of inpatient asthma care. ER -