PT - JOURNAL ARTICLE ED - American Association for Respiratory Care TI - Endotracheal Suctioning of Mechanically Ventilated Patients With Artificial Airways 2010 DP - 2010 Jun 01 TA - Respiratory Care PG - 758--764 VI - 55 IP - 6 4099 - http://rc.rcjournal.com/content/55/6/758.short 4100 - http://rc.rcjournal.com/content/55/6/758.full AB - An electronic literature search for articles published between January 1990 and October 2009 was conducted by using MEDLINE, CINAHL, and Cochrane Library databases. The update of this clinical practice guideline is the result of reviewing a total of 114 clinical trials, 62 reviews and 6 meta-analyses on endotracheal suctioning. The following recommendations are made following the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) criteria: (1) It is recommended that endotracheal suctioning should be performed only when secretions are present, and not routinely; (2) It is suggested that pre-oxygenation be considered if the patient has a clinically important reduction in oxygen saturation with suctioning; (3) Performing suctioning without disconnecting the patient from the ventilator is suggested; (4) Use of shallow suction is suggested instead of deep suction, based on evidence from infant and pediatric studies; (5) It is suggested that routine use of normal saline instillation prior to endotracheal suction should not be performed; (6) The use of closed suction is suggested for adults with high FIO2, or PEEP, or at risk for lung derecruitment, and for neonates; (7) Endotracheal suctioning without disconnection (closed system) is suggested in neonates; (8) Avoidance of disconnection and use of lung recruitment maneuvers are suggested if suctioning-induced lung derecruitment occurs in patients with acute lung injury; (9) It is suggested that a suction catheter is used that occludes less than 50% the lumen of the endotracheal tube in children and adults, and less than 70% in infants; (10) It is suggested that the duration of the suctioning event be limited to less than 15 seconds.