Abstract
This study determined which variables affected endotracheal tube“leak”pressures in 80 surgical patients, two weeks to 11 years of age, intubated with uncuffed tracheal tubes. We defined “leak” pressure as the inspiratory pressure needed to cause an audible escape of gas around the endotracheal tube.“Leak”pressure was measured after varying either head position, tracheal tube depth within the trachea, fresh gas flow rate, or degree of neuromuscular block.“Leak”pressure increased progressively from 16.9 ± 1.3 cm H20 with complete patient paralysis to 30.6 ± 1.4 cm H20 following 100 per cent recovery of neuromuscular function. Turning the head from a neutral position to one side increased “leak”pressure from 14.7 ±1.7cm H20 to24.4 ±2.5cm H20. Varying tracheal tube depth or fresh gas flow rate produced no significant change in“leak”pressure. Thus, there may be marked variability in“leak”pressure, depending on head position and degree of neuromuscular blockade. Keeping the patient fully paralyzed with the head in a neutral position provides a reliable and consistent method for measuring“leak”pressures.
Résumé
Cette étude a déterminé les variables qui affectent les fuites autour des tubes endotrachéaux sans ballonnet chez 80 patients agés de deux semaines à 11 ans, se présentant pour chirurgie. On définit la pression de fuite comme étant la pression inspiratoire nécessaire afin de provoquer une fuite audible de gaz autour du tube endotrachéal. La pression de fuite a été mesurée après variation soit de la position de la tête, soit de la profondeur du tube endotrachéal d l’intérieur de la trachée, soit en variant le débit de gaz frais, ou le degré de blocage neuromusculaire. La pression de fuite augmenta progressivement de 16.9 ± 1.3 cm H20 avec un patient complètement paralysé d 30.6 ± 1.4 cm H20 après reprise à 100 pour cent de la fonction neuromusculoire. En tournant la tête d’un cäté ou d’un autre à partir de la position neutre, on a augmenté la pression de fuite de 14.7 ± 1.7cm H2O à24.4 ±2.5cm H2O. La variation de la profondeur du tube endotrachéal dans la trachée ou le flot de gaz frais na pas produit de changement significatif dans les pressions de fuite. Ainsi il peut exister une variabilité marquée dans la pression de fuite dépendamment de la position de la tête ainsi que du degré du blocage neuromusculaire. En gardant le patient complètement paralysé avec la tête en position neutre, on fournit une méthode fiable et constante pour mesure les pressions de fuite.
Article PDF
Similar content being viewed by others
References
Eckenhoff JE. Some anatomic considerations of the infant larynx influencing endotracheal anesthesia. Anesthesiology 1951; 12:401–10.
Rasche RFH, Kuhns LR. Histopathologic changes in airway mucosa of infants after endotracheal intubation. Pediatrics 1972; 50:632–7.
Abbott TR. Complications of prolonged nasotracheal intubation in children. Br J Anaesth 1968; 40:347–52.
Markham WG, Blackwood MJA, Conn AW. Prolonged nasotracheal intubation in infants and children. Can Anaesth Soc J 1967; 14:11–21.
Strong RM, Dassy V. Endotracheal intubation. Arch Otolaryngol 1977; 103:329–35.
Chodoff P, Helrich M. Factors affecting pediatric endotracheal tube size: a statistical analysis. Anesthesiology 1967; 28:779–82.
Allen TH, Steven IM. Prolonged nasotracheal intubation in infants and children. Br J Anaesth 1972; 44:835–9.
Battersby EF, Hatch DJ, Towey RM. The effects of prolonged naso-endotracheal intubation in children. Anaesthesia 1977; 32:154–7.
Koka BV, leon IS, Andre JM, MacKay I, Smith RM. Postintubation croup in children. Anesth Analg 1977; 56:501–5.
Lee KW, Templeton J, Dougal RM. Tracheal tube size and postintubation croup in children. Anesthesiology 1980; 53:S325.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Finholt, D.A., Henry, D.B. & Raphaely, R.C. Factors affecting leak around tracheal tubes in children. Can Anaesth Soc J 32, 326–329 (1985). https://doi.org/10.1007/BF03011335
Issue Date:
DOI: https://doi.org/10.1007/BF03011335