Abstract
Objective
To establish the incidence of central venous catheter erosion in a patient cohort receiving total parenteral nutrition and to examine risk factors and complications of vascular erosion.
Design and setting
Review of prospectively collected intravenous nutrition service audit records in a tertiary university hospital.
Results
Records of 1,499 patients (2,992 catheters) were studied over the 14 year period 1991–2005. Fisher's exact test was used to determine statistical significance. Five erosions occurred, representing an incidence of 0.17% per catheter or 0.28 per 1,000 catheter days. One of the five patients died from ensuing complications. Mean time to onset of symptoms was 3.6 days following catheter insertion. Symptoms/signs included dyspnoea (n = 5), chest pain (n = 2) and pleural effusion (n = 5). Diagnosis was delayed by a mean of 1.6 days. Three erosions occurred in left subclavian catheters (n = 583); two in left internal jugular catheters (n = 453). None occurred in right-sided catheters (n = 1956). The relative risk of erosion occurring in left-sided catheters compared to right was 2.9 (95% CI 2.76–3.00; p = 0.009). There was no statistically significantly greater risk of vascular erosion in subclavian than internal jugular catheters (relative risk 0.9; p = 1.0). Older age was a statistically significant risk factor (p = 0.009); female sex was not (p = 0.18).
Conclusion
In patients receiving total parenteral nutrition via central venous catheters, erosion has an incidence per catheter of 0.17% and is more likely to occur in left-sided catheters and elderly patients.
References
Duntley P, Siever J, Korwes M, Harpel K, Heffner J (1992) Vascular erosion by central venous catheters. clinical features and outcome. Chest 101:1633–1638
Mukau L, Talamini M, Sitzmann J (1991) Risk factors for central venous catheter-related vascular erosions. J Parenter Enter Nutr 15:513–516
Vesely T (2003) Central venous catheter tip position: a continuing controversy. J Vasc Interv Radiol 24:527–534
Stonelake PA, Bodenham AR (2006) The carina as a radiological landmark for central venous catheter tip position. Br J Anaesth 96:335–340
Aslamy Z, Dewald CL, Heffner JE (1998) MRI of central venous anatomy: implications for central venous catheter insertion. Chest 114:820–826
Kowalshi CM, Kaufman JA, Rivitz SM, Geller SC, Waltman AC (1997) Migration of central venous catheters: implications for initial catheter tip positioning. J Vasc Interv Radiol 8:443–447
Tocino I, Watanabe A (1986) Impending catheter perforation of superior vena cava: radiographic recognition. Am J Roentgenol 146:487–490
Polderman KH, Girbes ARJ (2002) Central venous catheter use. 1. Mechanical complications. Intensive Care Med 28:1–17
Bersten A, Williams R, Phillips G (1988) Central venous catheter stiffness and its relation to vascular perforation. Anaesth Intensive Care 16:342–351
Diaz M, Lorda I, Sanchez C, Gutierrez I, Monton JM, Vidal A (2005) Milky-white pleural effusion complicating peripherally inserted central venous catheter for total parenteral nutrition. Eur J Clin Nutr 59:302–303
Mohammed AH, Tonkin L, Jerwood C (2005) Tension hydrothorax: a near-fatal complication of central venous catheterisation. J Cardiothorac Anesth 19:512–515
Paw HGW (2002) Bilateral pleural effusions: unexpected complication after left internal jugular venous catheterisation for total parenteral nutrition. BJA 89:647–650
Ellis L, Vogel S, Copeland E (1989) Central venous catheter vascular erosions: diagnosis and clinical course. Ann Surg 209:475–478
Acknowledgements
We are grateful to Dr G. O'Leary for the pilot study and Professor D.J. Cooper for critical comment and review.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Walshe, C., Phelan, D., Bourke, J. et al. Vascular erosion by central venous catheters used for total parenteral nutrition. Intensive Care Med 33, 534–537 (2007). https://doi.org/10.1007/s00134-006-0507-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00134-006-0507-9