Skip to main content
Log in

Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

  • Chest radiology
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal – not diffuse – airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six of 26 patients with restrictive lung function impairment exhibited focal airtrapping (mean score 2.4), whereas only 72 of 98 (74 %) patients with obstruction did (mean score 1.5; p < 0.05). Fifty-eight of 70 (83 %) patients with normal lung function (mean score 1.8) and 19 of 23 (83 %) patients with mixed impairment (mean score 1.8) had focal airtrapping. Focal airtrapping showed negative correlations with static lung volumes (–0.27 to –0.37; p < 0.001) in all patients and moderate positive correlations with dynamic parameters (0.3–0.4; p < 0.001) in patients with obstruction. No significant correlations were found with age, gender, and blood gas analysis. Visual assessment of focal – not diffuse – airtrapping at expiratory high-resolution CT does not correlate with physiological evidence of obstruction as derived from pulmonary function tests since the perception of focal airtrapping requires an adequate expiratory increase in lung density.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 11 February 2000; Revised: 8 June 2000; Accepted: 9 June 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kauczor, HU., Hast, J., Heussel, C. et al. Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests. Eur Radiol 10, 1539–1546 (2000). https://doi.org/10.1007/s003300000566

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300000566

Navigation