Effects of inspiratory impedance on hemodynamic responses to a squat–stand test in human volunteers: implications for treatment of orthostatic hypotension

  • Original Article
  • Published:
European Journal of Applied Physiology Aims and scope Submit manuscript

Abstract

Recent studies in our laboratory demonstrated that spontaneous breathing through an inspiratory impedance threshold device (ITD) increased heart rate (HR), stroke volume (SV), cardiac output (Q), and mean arterial blood pressure (MAP) in supine human subjects. In this study, we tested the effectiveness of an ITD as a countermeasure against development of orthostatic hypotension, provoked using a squat-to-stand test (SST). Using a prospective, randomized blinded protocol, 18 healthy, normotensive volunteers (9 males, 9 females) completed two-counterbalanced 6-min SST protocols with and without (sham) an ITD set to open at 0.7 kPa (7-cm H2O) pressure. HR, SV, Q, total peripheral resistance (TPR), and MAP were assessed noninvasively with infrared finger photoplethysmography. Symptoms were recorded on a 5-point scale (1=normal; 5=faint) of subject perceived rating (SPR). The reduction in TPR produced by SST (−35±5 %) was not affected by the ITD. Reduction in MAP with ITD during the transient phase of the SST (−3.6±0.5 kPa or −27±4 mmHg) was less (P=0.03) than that measured while breathing through a sham device (−4.8±0.4 kPa or −36±3 mmHg) despite similar (P<0.926) elevations in HR of 15±2 bpm. SV (+2±4 %) and Q (+22±5 %) with the ITD were higher (P<0.04) than SV (−8±4 %) and Q (+10±6 %) without the ITD. SPR was 1.4±0.1 with ITD compared to 2.0±0.2 with the sham device (P<0.04). This reduction in orthostatic symptoms with application of an ITD during the SST was associated with higher MAP, SV and Q. Our results demonstrate the potential application of an ITD as a countermeasure against orthostatic hypotension.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  • Blomqvist CG, Stone HL (1982) Cardiovascular adjustments to gravitational stress. In: Shepherd JT, Abboud FM (eds) Handbook of physiology, Chapter 28. The cardiovascular system, vol III. Peripheral circulation and organ blood flow, Part 2. Arnerican Physiological Society, Bethesda, pp 1025–1063

  • Buckey JC Jr, Lane LD, Levine BD, Watenpaugh DE, Wright SJ, Moore WE, Gaffney FA, Blomqvist CG (1996) Orthostatic intolerance after spaceflight. J Appl Physiol 81:7–18

    Google Scholar 

  • Coast TR, Jensen RA, Cassidy SS, Ramanathan M, Johnson RL Jr (1988) Cardiac output and O2 consumption during inspiratory threshold loaded breathing. J Appl Physiol 64:1624–1628

    CAS  PubMed  Google Scholar 

  • Convertino VA (1998) Gender differences in autonomic functions associated with blood pressure regulation. Am J Physiol 275:R1909–R1920

    CAS  PubMed  Google Scholar 

  • Convertino VA (1999) G-factor as a tool in basic research: mechanisms of orthostatic tolerance. J Gravit Physiol 6:P73–P76

    CAS  PubMed  Google Scholar 

  • Convertino VA (2002) Mechanisms of microgravity-induced orthostatic intolerance and implications of effective countermeasures: overview and future directions. J Gravit Physiol 9:1–12

    PubMed  Google Scholar 

  • Convertino VA, Cooke WH (2002) Relationship between stroke volume and sympathetic nerve activity: new insights about autonomic mechanisms of syncope. J Gravit Physiol 9:P63–P66

    PubMed  Google Scholar 

  • Convertino VA, Sather TM (2000) Vasoactive neuroendocrine responses associated with tolerance to lower body negative pressure in humans. Clin Physiol 20:177–184

    Article  CAS  PubMed  Google Scholar 

  • Convertino VA, Tripp LD, Ludwig DA, Duff J, Chellette TL (1998) Female exposure to high G: chronic adaptations of cardiovascular functions. Aviat Space Environ Med 69:875–882

    CAS  PubMed  Google Scholar 

  • Convertino VA, Ratliff DA, Ryan KL, Cooke WH, Doerr DF, Ludwig DA, Muniz GW, Britton DL, Clah SD, Fernald KB, Ruiz AF, Idris AH, Lurie KG (2004b). Effects of inspiratory impedance on the carotid-cardiac baroreflex response in humans. Clin Auton Res 14:140–148

    Article  PubMed  Google Scholar 

  • Convertino VA, Ratliff D, Ryan KL, Doerr DF, Ludwig DA, Muniz GW, Britton DL, Clah SD, Fernald KB, Ruiz AF, Idris AH, Lurie KG (2004c) Hemodynamics associated with breathing through an inspiratory impedance threshold device in human volunteers. Crit Care Med 32(Suppl):S381–S386

    Article  PubMed  Google Scholar 

  • Convertino VA, Ludwig DA, Cooke WH (2004a) Stroke volume reductions and sympathetic efferent responses reveal new insight into mechanisms of circulatory shock in humans. Auton Neurosci 111:127–134

    Article  PubMed  Google Scholar 

  • Convertino VA, Cooke WH, Lurie KG (2005) Inspiratory resistance as a potential treatment for orthostatic intolerance and hemorrhagic shock. Aviat Space Environ Med 76:319–325

    PubMed  Google Scholar 

  • Cooke WH, Lurie KG, Rohrer MJ, Convertino VA (2005) Human autonomic and cerebrovascular responses to inspiratory impedance. J Trauma (in press)

  • Eckberg DL, Sleight P (1992) Human baroreflexes in health and disease. Oxford University Press, New York, pp 256–259

    Google Scholar 

  • Grubb BP, Kosinski DJ, Kanjwal Y (2003) Orthostatic hypotension: causes, classification, and treatment. Pacing Clin Electrophysiol 26:892–901

    Article  PubMed  Google Scholar 

  • Hellstrom LG, Larsson H, Linnarsson D (1999) Implementation of a respiratory drive monitor on a servo ventilator. J Clin Monit 15:163–170

    Article  CAS  Google Scholar 

  • Imholz BPM, Van Montfrans GA, Settels JJ, Van Der Hoeven GMA, Karemaker JM, Wieling W (1988) Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre. Cardiovasc Res 22:390–397

    CAS  PubMed  Google Scholar 

  • Kimberly DS, Shoemaker JK (2002) Hypovolemia and neurovascular control during orthostatic stress. Am J Physiol 282:H645–H655

    Google Scholar 

  • Low PA, Opfer-Gehrking TL, Textor SC, Benarroch EE, Shen WK, Schondorf R, Suarez GA, Rummans TA (1995) Postural tachycardiac syndrome (POTS). Neurology 45:S19–S25

    CAS  Google Scholar 

  • Lurie KG, Coffeen PR, Shultz JJ, McKnite SH, Detloff BS (1995) Improving active compression- decompression cardiopulmonary resuscitation with an inspiratory impedance valve. Circulation 91:1629–1632

    CAS  PubMed  Google Scholar 

  • Lurie KG, Mulligan KA, McKnite S, Detloff B, Lindstrom P, Lindner KH (1998) Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Chest 113:1084–1090

    CAS  PubMed  Google Scholar 

  • Lurie KG, Voelckel W, Plaisance P, Zielinski T, McKnite S, Kor D, Sugiyama A, Sukhum P (2000a) Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report. Resuscitation 44:219–230

    Article  CAS  PubMed  Google Scholar 

  • Lurie KG, Zielinski T, McKnite S, Sukhum P (2000b) Improving the efficiency of cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Crit Care Med 28(Suppl):N207–N209

    Article  CAS  PubMed  Google Scholar 

  • Lurie KG, Voelckel WG, Zielinski T, McKnite S, Lindstrom P, Peterson C, Wenzel V, Lindner KH, Samniah N, Benditt D (2001) Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest. Anesth Analg 93:649–655

    Article  CAS  PubMed  Google Scholar 

  • Lurie KG, Zielinski T, McKnite S, Aufderheide T, Voelckel W (2002a) Use of an inspiratory impedance valve improves neurologically intact survival in a porcine model of ventricular fibrillation. Circulation 105:124–129

    Article  PubMed  Google Scholar 

  • Lurie KG, Zielinski T, Voelckel W, McKnite S, Plaisance P (2002b) Augmentation of ventricular preload during treatment of cardiovascular collapse and cardiac arrest. Crit Care Med 30(Suppl):S162–S165

    Article  PubMed  Google Scholar 

  • Lurie KG, Zielinski TM, McKnite SH, Idris AH, Yannopoulos D, Raedler CM, Sigurdsson G, Benditt DG, Voelckel WG (2004) Treatment of hypotension in pigs with an inspiratory impedance threshold device: a feasibility study. Crit Care Med 32:1555–1562

    Article  PubMed  Google Scholar 

  • Plaisance P, Lurie KG, Payen D (2000) Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation. Circulation 101:989–994

    CAS  PubMed  Google Scholar 

  • Raven PB, Potts JT, Shi X (1997) Baroreflex regulation of blood pressure during dynamic exercise. Exerc Sports Sci Rev 25:365–390

    CAS  Google Scholar 

  • Rowell LB (1986) Human circulation regulation during physical stress. Oxford University Press, New York, chapt 7, pp 147–148

  • Samniah N, Voeickel WG, Zielinski TM, McKnite S, Patterson R, Benditt DG, Lurie KG (2003) Feasibility and effects of transcutaneous phrenic nerve stimulation combined with an inspiratory impedance threshold in a pig model of hemorrhagic shock. Crit Care Med 31:1197–1202

    Article  PubMed  Google Scholar 

  • Shoemaker JK, Hogeman CS, Sinoway LL (1999) Contributions of MSNA and stroke volume to orthostatic intolerance following bed rest. Am J Physiol 277:Rl084–R1090

    Google Scholar 

  • Waters W, Ziegler M, Meck J (2002) Postspaceflight orthostatic hypotension occurs mostly in women and is predicted by low vascular resistance. J Appl Physiol 92:586–594

    PubMed  Google Scholar 

  • Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ (1993) Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 74:2566–2573

    CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors thank the subjects for their cheerful cooperation; Sandy Reed, Barry Slack and Robert Cummings for their engineering and technical assistance during the experiments; Greg Hall for computer programming of LabView data acquisition; Ivonne Garcia for her assistance with medical monitoring of the subjects during the experiments; Colie G. Warren, Kevin Eisenhower and Joseph Sithole for assistance with data collection; and the participation of the 2003 NASA Space Life Sciences Training Program for their assistance in data collection and analysis. This research was supported by Cooperative Research and Development Agreements between the US Army Institute of Surgical Research (USAISR) and the National Aeronautics and Space Administration (CRDA No. DAMD17-01-0112) and between the USAISR and Advanced Circulatory Systems, Inc. (CRDA No. DAMD17-02-0160), Department of Defense Small Business Innovative Research #W81XWH-04-C-0022 grant award to Advanced Circulatory Systems, Inc., Eden Prairie, Minnesota, and by funding from the US Army Combat Casualty Care Research Program. The views expressed herein are the private views of the authors and are not to be construed as representing those of the National Aeronautics and Space Administration, Department of Defense, or Department of the Army. Disclaimer: K. Lurie is a coinventor of the impedance threshold device and founded Advanced Circulatory Systems, Inc. to develop the device.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Victor A. Convertino.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Convertino, V.A., Ratliff, D.A., Crissey, J. et al. Effects of inspiratory impedance on hemodynamic responses to a squat–stand test in human volunteers: implications for treatment of orthostatic hypotension. Eur J Appl Physiol 94, 392–399 (2005). https://doi.org/10.1007/s00421-005-1344-1

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00421-005-1344-1

Keywords

Navigation