Effects of short vs. prolonged mechanical ventilation on antioxidant systems in piglet diaphragm

Intensive Care Med. 2005 Oct;31(10):1427-33. doi: 10.1007/s00134-005-2694-1. Epub 2005 Jul 22.

Abstract

Objective: Prolonged controlled mechanical ventilation (MV) is known to induce diaphragmatic oxidative stress that seems to be an important factor reducing force-generating capacity. To better understand the cellular mechanisms involved, this work examined the effect of short vs. prolonged MV on antioxidant defense in the diaphragm.

Design and setting: Prospective, randomized, controlled animal study in a university laboratory.

Methods: Eleven piglets (15-20 kg) were assigned to one of two groups: a long-MV group (n=6) ventilated for 3 days or a short-MV group (n=5) ventilated for 3 h. Force frequency curves of the transdiaphragmatic pressure (Pdi) were obtained in vivo by phrenic nerve pacing. Oxidative stress was evaluated by thiobarbituric reactive substance (TBARs) content and the enzymatic antioxidant activity of both superoxide dismutase (SOD) and glutathione peroxidase (GPx) in samples of diaphragm.

Results: Pdi decreased in the long-MV group by 30-35% over the 3 days at all frequencies compared to the short-MV group. Diaphragm TBARs content was significantly higher and SOD activity lower in long-MV animals than in short-MV animals after 72 h. GPx activity tended to be lower in diaphragms from long-MV animals, but this difference was not significant.

Conclusions: This study shows that 3 days of MV in piglets is associated with a decrease in antioxidant activity which could emphasize oxidative stress and both contribute to the diaphragm dysfunction caused by MV.

MeSH terms

  • Animals
  • Blood Gas Analysis
  • Blood Pressure
  • Diaphragm / physiology*
  • Muscle Contraction
  • Oxidative Stress*
  • Respiration, Artificial / adverse effects*
  • Swine
  • Time Factors
  • Ventilator Weaning