Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

J Cardiothorac Surg. 2012 Jan 25:7:11. doi: 10.1186/1749-8090-7-11.

Abstract

Background: Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB) using left internal thoracic artery (LITA).

Methods: Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position); II (n = 33 intact pleural cavity). Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD) 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5.

Results: In both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups.

Conclusion: Subxyphoid insertion of pleural drain provides similar effects to preserved pleural integrity in pulmonary function, clinical outcomes, and thoracic pain after OPCAB. Therefore, our results support the hypothesis that once pleural cavities are incidentally or purposely opened during LITA dissection, subxyphoid placement of the pleural drain is recommended.

MeSH terms

  • Coronary Artery Bypass, Off-Pump*
  • Female
  • Humans
  • Lung / physiology*
  • Male
  • Mammary Arteries
  • Middle Aged
  • Pleura / surgery*
  • Respiratory Function Tests
  • Suction / methods*
  • Xiphoid Bone