Impact of early passive exercise with cycle ergometer on ventilator interaction

JR Silva, MM Reboredo, BC Bergamini, CB Netto… - Respiratory …, 2020 - rc.rcjournal.com
BACKGROUND: Early exercise has been recommended in critically ill patients, but its
impact on subject–ventilator interaction is still unclear. Therefore, the aim of this study was to …

Time-dependence influence on mechanical properties of the respiratory system in two strategies for decremental positive end-expiratory pressure titration

BC Bergamini, NS Carvalho, DM Medeiros… - A48. MECHANICAL …, 2012 - atsjournals.org
Time-Dependence Influence On Mechanical Properties Of The Respiratory System In Two
Strategies For Decremental Positive End-Expi Page 1 / Thematic Poster Session / Sunday, May …

Positive Pressure Exacerbates Hemodynamic Instability In Wistar Rats

NS Carvalho, BC Bergamini… - … IN THE INTENSIVE …, 2012 - atsjournals.org
Positive Pressure Exacerbates Hemodynamic Instability In Wistar Rats CONCLUSION: In Wistar
rats chest wall may limit the full lu Page 1 / Thematic Poster Session / Tuesday, May 22/8:15 C57 …

State-of-the-art and perspectives in the use of biochar for electrochemical and electroanalytical applications

…, AS Mangrich, LH Marcolino-Junior, MF Bergamini - Green chemistry, 2021 - pubs.rsc.org
The depletion of natural resources and consequently increase in the importance of
environmental conservation are reflected in the scientific community. The search for scientific …

3D-printed electrode as a new platform for electrochemical immunosensors for virus detection

…, BC Janegitz, LH Marcolino-Junior, MF Bergamini - Analytica Chimica …, 2021 - Elsevier
Simple, low-cost, and sensitive new platforms for electrochemical immunosensors for virus
detection have been attracted attention due to the recent pandemic caused by a new type of …

[HTML][HTML] Disposable and flexible electrochemical sensor made by recyclable material and low cost conductive ink

…, RC Faria, LH Marcolino-Junior, MF Bergamini… - Journal of …, 2019 - Elsevier
Disposable electrochemical sensors by using recyclable materials are an interesting alternative
to produce electrochemical sensors with an extreme low cost. In addition, the screen-…

[HTML][HTML] Electrochemical biosensor for SARS-CoV-2 cDNA detection using AuPs-modified 3D-printed graphene electrodes

…, E Carrilho, LH Marcolino-Junior, MF Bergamini… - Biosensors, 2022 - mdpi.com
A low-cost and disposable graphene polylactic (G-PLA) 3D-printed electrode modified with
gold particles (AuPs) was explored to detect the cDNA of SARS-CoV-2 and creatinine, a …

[HTML][HTML] Using low-cost disposable immunosensor based on flexible PET screen-printed electrode modified with carbon black and gold nanoparticles for sensitive …

…, PR Martins, LH Marcolino-Junior, MF Bergamini… - Talanta open, 2023 - Elsevier
To help meet the global demand for reliable and inexpensive COVID-19 testing and
environmental analysis of SARS-CoV-2, the present work reports the development and application …

Analysis of synovial fluid of the Capybara's stifle joints

GC Brombini, SC Rahal, BCS Bergamini… - Veterinary clinical …, 2017 - Wiley Online Library
Background Although normal synovial fluid has been well characterized in domestic animals
such as dogs, cats, horses, and cows, the available information on larger rodents is scarce. …

One-step selective layer assemble: A versatile approach for the development of a SARS-CoV-2 electrochemical immunosensor

…, EM de Souza, LH Marcolino-Junior, MF Bergamini - Analytica Chimica …, 2023 - Elsevier
The appearance of new viruses and diseases has made the development of rapid and
reliable diagnostic tests crucial. In light of it, we proposed a new method for assembling an …