User profiles for Jean-Marie Tonnelier

Jean-Marie TONNELIER

MD
Verified email at chu-brest.fr
Cited by 5536

[HTML][HTML] High versus low blood-pressure target in patients with septic shock

…, C Guitton, F Tamion, JM Tonnelier… - … England Journal of …, 2014 - Mass Medical Soc
Background The Surviving Sepsis Campaign recommends targeting a mean arterial pressure
of at least 65 mm Hg during initial resuscitation of patients with septic shock. However, …

[HTML][HTML] High-flow oxygen through nasal cannula in acute hypoxemic respiratory failure

…, M Fartoukh, JM Constantin, JM Tonnelier… - … England Journal of …, 2015 - Mass Medical Soc
Background Whether noninvasive ventilation should be administered in patients with acute
hypoxemic respiratory failure is debated. Therapy with high-flow oxygen through a nasal …

Diagnostic strategy for hematology and oncology patients with acute respiratory failure: randomized controlled trial

…, C Cracco, B Renard, JM Tonnelier… - American journal of …, 2010 - atsjournals.org
Rationale: Respiratory events are common in hematology and oncology patients and manifest
as hypoxemic acute respiratory failure (ARF) in up to half the cases. Identifying the cause …

Neurologic complications and outcomes of infective endocarditis in critically ill patients: the ENDOcardite en REAnimation prospective multicenter study

…, O Pajot, AM Dessap, JM Tonnelier… - Critical care …, 2011 - journals.lww.com
Objective: To describe the clinical spectrum of infective endocarditis in critically ill patients
and assess the impact of neurologic complications on outcomes. Design: Prospective …

Endovascular versus external targeted temperature management for patients with out-of-hospital cardiac arrest: a randomized, controlled study

…, N Pichon, B Megarbane, P Midez, JM Tonnelier… - Circulation, 2015 - Am Heart Assoc
Background— Targeted temperature management is recommended after out-of-hospital
cardiac arrest. Whether advanced internal cooling is superior to basic external cooling remains …

Anti–N-Methyl-d-Aspartate Receptor Encephalitis in Adult Patients Requiring Intensive Care

…, M Alves, M Cour, N Engrand, JM Tonnelier… - American journal of …, 2017 - atsjournals.org
Rationale: Encephalitis caused by anti–N-methyl-d-aspartate receptor (NMDAR) antibodies
is the leading cause of immune-mediated encephalitis. There are limited data on intensive …

Long-term outcomes and cardiac surgery in critically ill patients with infective endocarditis

…, A Mekontso-Dessap, JM Tonnelier… - European heart …, 2014 - academic.oup.com
Aims To assess long-term outcomes and the management of critical left-sided infective
endocarditis (IE) and evaluate the impact of surgery. Methods and results Among the 198 patients …

Clinical relevance of classification according to weaning difficulty

A Tonnelier, JM Tonnelier, E Nowak… - Respiratory …, 2011 - rc.rcjournal.com
OBJECTIVE: To evaluate the clinical relevance of the weaning from mechanical ventilation
classification system derived from the 2005 international consensus conference, in patients …

[HTML][HTML] Impact of a nurses' protocol-directed weaning procedure on outcomes in patients undergoing mechanical ventilation for longer than 48 hours: a prospective …

JM Tonnelier, G Prat, G Le Gal, C Gut-Gobert… - Critical Care, 2005 - Springer
Introduction The aim of the study was to determine whether the use of a nurses' protocol-directed
weaning procedure, based on the French intensive care society (SRLF) consensus …

Feasibility and potential cost/benefit of routine isoflurane sedation using an anesthetic-conserving device: a prospective observational study

E L'her, D Lenaïg, R Pili, G Prat, JM Tonnelier… - Respiratory …, 2008 - rc.rcjournal.com
BACKGROUND: Inhaled sedation is efficient and easily controllable; in low concentrations it
causes minimal changes in the patient and very little interference with hemodynamics. …