[BOOK][B] Structural analysis of point defects in solids: an introduction to multiple magnetic resonance spectroscopy

JM Spaeth, JR Niklas, RH Bartram - 2012 - books.google.com
Strutural Analysis of Point Defects in Solids introduces the principles and techniques of
modern electron paramagnetic resonance (EPR) spectroscopy essentialfor applications to the …

[BOOK][B] Point defects in semiconductors and insulators: determination of atomic and electronic structure from paramagnetic hyperfine interactions

JM Spaeth, H Overhof - 2013 - books.google.com
The precedent book with the title" Structural Analysis of Point Defects in Solids: An introduction
to multiple magnetic resonance spectroscopy" ap peared about 10 years ago. Since then …

Photostimulated luminescence in Eu-doped fluorochlorozirconate glass ceramics

S Schweizer, LW Hobbs, M Secu, JM Spaeth… - Applied Physics …, 2003 - pubs.aip.org
We report the synthesis of Eu 2+ - and chlorine-doped fluorozirconate glass-ceramics that
show an intense photostimulated luminescence (PSL) after x-ray irradiation at room …

Photostimulated luminescence from fluorochlorozirconate glass ceramics and the effect of crystallite size

S Schweizer, LW Hobbs, M Secu, JM Spaeth… - Journal of applied …, 2005 - pubs.aip.org
We report the results from a study of europium-doped fluorochlorozirconate glasses that
have been thermally processed to induce nucleation and crystallization of BaCl 2 crystallites. …

Application of the novel ventilation mode flow-controlled expiration (FLEX): a crossover proof-of-principle study in lung-healthy patients

S Wirth, S Springer, J Spaeth, S Borgmann… - Anesthesia & …, 2017 - journals.lww.com
BACKGROUND: Traditionally, mechanical ventilation is achieved via active lung inflation
during inspiration and passive lung emptying during expiration. By contrast, the novel FLEX (…

[HTML][HTML] Pneumoperitoneum deteriorates intratidal respiratory system mechanics: an observational study in lung-healthy patients

S Wirth, A Biesemann, J Spaeth, S Schumann - Surgical endoscopy, 2017 - Springer
Background Pneumoperitoneum during laparoscopic surgery leads to atelectasis and
impairment of oxygenation. Positive end-expiratory pressure (PEEP) is supposed to counteract …

The pressure drop across the endotracheal tube in mechanically ventilated pediatric patients

J Spaeth, D Steinmann, H Kaltofen… - Pediatric …, 2015 - Wiley Online Library
Background During mechanical ventilation, the airway pressure (P aw ) is usually monitored.
However, P aw comprises the endotracheal tube ( ETT )‐related pressure drop (∆ P ETT ) …

Intratidal recruitment/derecruitment persists at low and moderate positive end-expiratory pressure in paediatric patients

…, L Artner, T Broß, S Lozano-Zahonero, J Spaeth… - Respiratory physiology …, 2016 - Elsevier
In paediatric patients positive end-expiratory pressure (PEEP) is traditionally set lower than
in adults. We investigated whether moderately higher PEEP improves respiratory mechanics …

Incidence of gastric insufflation at high compared with low laryngeal mask cuff pressure: a randomised controlled cross-over trial

J Hell, H Pohl, J Spaeth, W Baar… - European Journal of …, 2021 - journals.lww.com
BACKGROUND The success of ventilation with a laryngeal mask depends crucially on the
seal between the mask and the periglottic tissue. Increasing the laryngeal mask's cuff volume …

[HTML][HTML] Establishment and validation of intravenous anesthesia with dexmedetomidine for pigs under assisted spontaneous breathing: A preclinical model of …

C Wenzel, SG Spassov, J Haberstroh, J Spaeth… - Plos one, 2023 - journals.plos.org
Large animal models are frequently used to investigate new medical approaches. In most
cases, animals are kept under general anesthesia and mandatory mechanical ventilation …