Use and outcomes of noninvasive positive pressure ventilation in acute care hospitals in Massachusetts
Background This study determined actual utilization rates and outcomes of noninvasive positive
pressure ventilation (NIV) at selected hospitals that had participated in a prior survey on …
pressure ventilation (NIV) at selected hospitals that had participated in a prior survey on …
Evaluation of the total face mask for noninvasive ventilation to treat acute respiratory failure
A Ozsancak, SS Sidhom, TN Liesching, W Howard… - Chest, 2011 - Elsevier
Background We hypothesized that the total face mask (TFM) would be perceived as more
comfortable than a standard oronasal mask (ONM) by patients receiving noninvasive …
comfortable than a standard oronasal mask (ONM) by patients receiving noninvasive …
[HTML][HTML] Where is noninvasive ventilation actually delivered for acute respiratory failure?
A Ozsancak Ugurlu, SS Sidhom, A Khodabandeh… - Lung, 2015 - Springer
Purpose Few studies have examined locations of noninvasive ventilation (NIV) application
for acute respiratory failure (ARF). We aimed to track actual locations of NIV delivery and …
for acute respiratory failure (ARF). We aimed to track actual locations of NIV delivery and …
Use and outcomes of noninvasive ventilation for acute respiratory failure in different age groups
BACKGROUND: The prevalence of chronic disease and do-not-intubate status increases
with age. Thus, we aimed to determine characteristics and outcomes associated with …
with age. Thus, we aimed to determine characteristics and outcomes associated with …
Effect of electro discharge machining (EDM) on the AISI316L SS white layer microstructure and corrosion resistance
… This study focuses on the AISI316L SS austenitic stainless steel that is known for its good
localised corrosion resistance. This material has been selected to produce some biomedical …
localised corrosion resistance. This material has been selected to produce some biomedical …
Double loop electrochemical potentiokinetic reactivation test optimization in checking of duplex stainless steel intergranular corrosion susceptibility
… It has been demonstrated in numerous cases of stainless steel (SS) or nickel alloys[4,12–26…
in the case of DL-EPR tests for super austenitic SS.[19] The potential scan rate remains …
in the case of DL-EPR tests for super austenitic SS.[19] The potential scan rate remains …
Effects of the cryogenic cooling on the fatigue strength of the AISI 304 stainless steel ground components
… The material used in this investigation is the austenitic stainless steel AISI 304, for which
the chemical composition and the mechanical properties are detailed in Table 2, Table 3, …
the chemical composition and the mechanical properties are detailed in Table 2, Table 3, …
Numerical and experimental analysis of residual stress and plastic strain distributions in machined stainless steel
In this study, a numerical approach has been developed to predict the near surface residual
stresses and plastic strain resulting from turning in orthogonal cutting configuration. This …
stresses and plastic strain resulting from turning in orthogonal cutting configuration. This …
Ground surface improvement of the austenitic stainless steel AISI 304 using cryogenic cooling
… integrity of the AISI 304 austenitic stainless steel ground under cryogenic cooling compared
… of the AISI 304 stainless steel. Indeed, the AISI 304 stainless steel is frequently used as a …
… of the AISI 304 stainless steel. Indeed, the AISI 304 stainless steel is frequently used as a …
Evaluation of residual stress relaxation and its effect on fatigue strength of AISI 316L stainless steel ground surfaces: Experimental and numerical approaches
This paper is aimed at evaluating the residual stress relaxation and its effect on the fatigue
strength of AISI 316L steel ground surfaces in comparison to electro-polished surfaces. An …
strength of AISI 316L steel ground surfaces in comparison to electro-polished surfaces. An …