Abstract
BACKGROUND: Expiratory rib cage compression (ERCC) has been empirically used by physiotherapists with the rationale of improving expiratory flows and therefore the airway clearance in mechanically ventilated patients. This study evaluates the acute mechanical effects and sputum clearance of an ERCC protocol in ventilated patients with pulmonary infection.
METHODS: In a randomized crossover study, sputum production and respiratory mechanics were evaluated in 20 mechanically ventilated subjects submitted to 2 interventions. ERCC intervention consisted of a series of manual bilateral ERCCs, followed by a hyperinflation maneuver. Control intervention (CTRL) followed the same sequence, but instead of the compressive maneuver, the subjects were kept on normal ventilation. Static (Cst) and effective (Ceff) compliance and total (Rtot) and initial (Rinit) resistance of the respiratory system were measured pre-ERCC (baseline), post-ERCC or CTRL (POST1), and post-hyperinflation (POST2). Peak expiratory flow (PEF) and the flow at 30% of the expiratory tidal volume (flow 30% VT) were measured during the maneuver.
RESULTS: ERCC cleared 34.4% more secretions than CTRL (1 [0.5–1.95] vs 2 [1–3.25], P < .01). Respiratory mechanics showed no differences between control and experimental intervention in POST1 for Cst, Ceff, Rtot, and Rinit. In POST2, ERCC promoted an increase in Cst (38.7 ± 10.3 vs 42.2 ± 12 mL/cm H2O, P = .03) and in Ceff (32.6 ± 9.1 vs 34.8 ± 9.4 mL/cm H2O, P = .04). During ERCC, PEF increased by 16.2 L/min (P < .001), and flow 30% VT increased by 25.3 L/min (P < .001) compared with CTRL. Six subjects (30%) presented expiratory flow limitation (EFL) during ERCC. The effect size was small for secretion volume (0.2), Cst (0.15), and Ceff (0.12) and negligible for Rtot (0.04) and Rinit (0.04).
CONCLUSIONS: Although ERCC increases expiratory flow, it has no clinically relevant effects from improving the sputum production and respiratory mechanics in hypersecretive mechanically ventilated patients. The maneuver can cause EFL in some patients. (ClinicalTrials.gov registration NCT01525121).
Introduction
Although a number of studies have focused on the effect of mechanical ventilation on the pulmonary parenchyma, more attention should be given to mucus clearance since its mechanisms in ventilated patients are still poorly understood. Furthermore, the advances in the understanding of simple interventions such as chest physiotherapy may contribute to reducing mucus retention and respiratory infections.1 Chest physiotherapy is an essential component of the multidisciplinary approach in critical care settings. In this context, a number of devices and manual techniques have been used to remove pulmonary secretions and re-expand collapsed areas.2 Thoracic manipulative techniques include expiratory rib cage compression (ERCC) or “squeezing.”3 This technique aims to increase expiratory flow and stretch intercostal muscles by means of a manual thoracic compression applied during exhalation, followed by a rapid release at the onset of inspiration.4 The rationale of this technique is based on its compressive effect on the airways, increasing the air-flow velocity, which increases mucus transport.5 As the application of mechanical forces on the thorax reduces the transpulmonary pressure, rib cage compression is likely to promote pulmonary and airway collapse, diminishing respiratory compliance and/or causing expiratory flow limitation (EFL).6,7 Previous animal studies showed no beneficial effects of ERCC on respiratory mechanics and gas exchange.8–10 Moreover, Unoki et al9 postulated that the airway and alveolar collapse may be exacerbated, which agrees with the results of Martí et al,10 who found a reduction in static compliance after applying the maneuver in an animal model. These authors also found an increase in mucus clearance with “hard expiratory rib cage compression” (brief and strong bilateral compressions); however, this was not observed in critical care patients, as reported by Unoki et al.4 Although there is no clear evidence for the physiological or airway clearance benefits of ERCC in humans, Berti et al11 found a positive effect on the duration of mechanical ventilation, as well as on the ICU discharge rate and Murray score when using ERCC along with manual hyperinflation. It is difficult to determine whether these beneficial clinical outcomes were due to ERCC, manual hyperinflation, or both, particularly because Genc et al12 observed no improvements in static compliance, gas exchange, and secretion clearance when ERCC was used with manual hyperinflation in 22 mechanically ventilated patients. It is likely that these conflicting results are due to the design differences between the studies, along with some potential confounding factors that were not considered. The present study was conducted to examine the acute mechanical effects and sputum clearance of an ERCC protocol in ventilated patients with pulmonary infection. We hypothesized that, although ERCC can promote EFL and lung collapse in some circumstances, this technique improves the airway clearance in hypersecretive mechanically ventilated patients.
QUICK LOOK
Current knowledge
Expiratory rib cage compression (ERCC) has been empirically used by respiratory therapists and physiotherapists in an attempt to enhance expiratory flows and facilitate airway clearance in mechanically ventilated patients.
What this paper contributes to our knowledge
ERCC increases expiratory flow but has no clinically relevant effects in improving the sputum production and respiratory mechanics in mechanically ventilated patients with retained secretions. ERCC can cause expiratory flow limitation in some patients.
Methods
Study Design
This was a randomized crossover study. Participants were recruited from patients admitted to an 11-bed ICU at a tertiary referral hospital. Allocation was concealed from the enrolling investigators, and randomization used 2 blocks of 10. The study coordinator prepared sealed opaque envelopes containing a preassigned treatment order generated by computer, which were opened sequentially by the physiotherapist on the day of intervention. According to the random order, the participants received manual ERCC and the control intervention (CTRL) on the same day, with a 5-h washout period between them. Both interventions were followed by a hyperinflation maneuver using pressure support ventilation. The study protocol is depicted in Figure 1.
Participants
All subjects were receiving mechanical ventilation, presenting medical diagnoses of pulmonary infection and hypersecretion (defined as the need for suctioning < 2-h intervals). Pulmonary infection was defined as a score of ≥ 6, as determined by the Clinical Pulmonary Infection Score (CPIS).13 CPIS was calculated after individual scoring for each of the following parameters: (1) temperature: 36.5–38.4°C = 0 points, 38.5–38.9°C = 1 point, ≤ 36°C or ≥ 39°C = 2 points; (2) white blood cells (× 109/L) 4.0–11.0 = 0 points, 11–17 = 1 point, > 17 = 2 points; (3) secretions: none to minimal = 0 points, moderate = 1 point, large = 2 points; (4) PaO2/FIO2: > 240 = 0 points, ≤ 240 = 2 points; (5) chest radiograph infiltrates: clear = 0 points, patchy = 1 point, localized = 2 points. Exclusion criteria included individuals with hemodynamic instability (defined by heart rate > 130 beats/min and/or mean arterial pressure < 60 mm Hg), use of vasopressor drugs, absence of respiratory drive, acute bronchospasm, ARDS, immediate postoperative neurosurgery, untreated pneumothorax, and lung hemorrhage. The research protocol was approved by the institution's ethics committee, and written informed consent was obtained from the subjects' next of kin before the study began.
Intervention
The subjects were kept in a 30° semifowlers, supine position. Ventilatory mode was changed to volume-controlled mode, with a tidal volume (VT) of 8 mL/kg, an inspiratory flow of 60 L/min (square wave), and PEEP of 5 cm H2O (FIO2 remained unchanged). A first tracheal suctioning was done, and the mucus was discarded. A series of 5 min of bilateral ERCCs then ensued. Aiming to minimize intertherapist variability, the technique was applied by the same registered and trained physiotherapist. His hands were positioned on the lower ribs, and force was applied every 2 breaths only during the expiration, synchronizing the maneuver rate with the breathing frequency of the subject. The subjects then underwent a new suctioning procedure, followed by a hyperinflation maneuver consisting of a 10-min period under pressure support ventilation of 35 cm H2O. Control intervention followed the same sequence, but instead of the compressive maneuver, the subjects were kept on normal ventilation with the parameters described above.
Outcome Measurements
Sputum Production.
Secretion clearance was the primary outcome and was measured as sputum volume (mL).14 Secretions were collected immediately after ERCC and CTRL, using a sputum trap attached to the suction system. Sterile saline (10 mL) was flushed through the suction tubing into the trap to clear any secretions in the catheter. The volume of sputum was recorded, subtracting the saline volume from the total volume in the trap. The suctioning procedure was performed following the American Association for Respiratory Care recommendations: closed suction system, suction catheter with maximal internal-to-external diameter ratio of 0.5, delivery of 100% oxygen 30 s immediately before and 1 min after the procedure, duration of 15 s, and vacuum pressure of −150 mm Hg.15
Respiratory Mechanics.
Respiratory mechanics were recorded immediately pre-ERCC (PRE), post-ERCC or CTRL (POST1), and post-hyperinflation (POST2). There were no intervals between these protocol steps and recording of respiratory mechanics.
For the measurements, the subjects were positioned supine with the head of the bed at 30° with a hyperinflated cuff and submitted to tracheal suctioning. After that, they received 3 sighs with a 2-fold increase in VT (volume history).16 According to the end-inspiratory occlusion method,17 peak pressure (P1), plateau pressure (P2), ΔP1 (P1 − inflection point pressure), inspiratory flow (flow), and VT were used to calculate static (Cst) and effective (Ceff) compliance of the respiratory system (Cst = VT/[P2 − PEEP]; Ceff = VT/[P1− PEEP]) and total (Rtot) and initial (Rinit) resistance of the respiratory system (Rtot = [P1 − P2]/flow; Rinit = ΔP1/flow). If there was total or partial superimposition in the expiratory flow-volume loop with and without a manual compression maneuver, this was considered EFL.18,19 In addition, peak expiratory flow (PEF) and flow at 30% of the expiratory tidal volume (flow 30% VT; aiming to record the flow in intermediate and/or peripheral airways) were also measured during ERCC. In all steps (PRE, POST1, and POST2), the respiratory signals were collected from the ventilator display (Vela, Infrasonics, San Diego, California), and the representative value for each respiratory mechanics variable was computed as an average of 3 consistent measures.
Statistical Analysis
According to the data from Lemes et al,20 power calculation indicated that 10 participants would provide sufficient power (80%) to detect a difference of 68% in sputum volume, assuming an SD of 67% and significance of 0.05.
Data were tested for normality and homogeneity of variances (Shapiro-Wilk test and Levene median test) and expressed as mean ± SD (if normally distributed) or as medians in combination with quartiles and percentiles (if not normally distributed). According to data distribution, the 2-way repeated measures analysis of variance and the Tukey test were used to examine the between-interventions differences in respiratory mechanics, and the Wilcoxon test was used to compare the sputum production between CTRL and ERCC. The significance level was set at 0.05, and the SigmaStat 3.1 software (Systat Software, San Jose, California) was used for all analyses. The clinical effect of ERCC was assessed by the effect size statistic, calculated as the mean change found in a variable divided by the SD of that variable.21 We used the criteria of Cohen22 to interpret the effect size, where a value of 0.2 is considered a small effect, a value of 0.5 is considered a moderate effect, and a value of 0.8 is considered a large effect. These calculations used the POST2 data, considering CTRL and ERCC results.
Results
Data from the participants of the study are provided in Table 1. The only center involved in this trial (Military Police of Rio de Janeiro State Hospital) has a throughput of 234 critical care patients per year, with 65% managed with mechanical ventilation. All participants completed the measurements, and their baseline respiratory mechanics values were similar before CTRL and ERCC (Table 2). One neurosurgical subject presented with a Glasgow coma score of 9. Three subjects were not sedated, and the other 16 subjects were sedated with midazolam (0.02–0.2 mg/kg/h) and/or fentanyl (1.0–7.0 μg/kg/h). The infusions were titrated with the aim of maintaining levels 2–4 in the Ramsay Sedation Scale.23 The same experienced physiotherapist delivered control and experimental interventions for all subjects, and the procedures were well tolerated without unfavorable signs and symptoms (alteration in blood pressure and/or heart rate > or < 20% of resting values and desaturation of oxyhemoglobin > 10% of baseline levels).24
The respiratory mechanics and expiratory flow profiles in CTRL and ERCC are shown in Tables 2 and 3, respectively. ERCC cleared 34.4% more secretions than CTRL (P = .04) (Fig. 2 and Table 2). Respiratory mechanics showed no differences between control and experimental interventions in POST1 for Cst (P = .1), Ceff (P = .34), Rtot (P = .92), and Rinit (P = .97). In POST2, ERCC promoted an increase in Cst (P = .025) and in Ceff (P = .044), but not in Rtot (P = .92) and Rinit (P = .98). The effect size was small for secretion volume (0.2), Cst (0.15), and Ceff (0.12) and negligible for Rtot (0.04) and Rinit (0.04).
During ERCC, PEF increased by 16.2 L/min (P < .001), and flow 30% VT increased by 25.3 L/min (P < .001) compared with CTRL (Table 3). Six patients (30%) presented EFL during ERCC. In a post hoc analysis comparing patients with EFL and non-EFL (NEFL), there was an increase in PEF during ERCC in NEFL (P = .007), but not in EFL (P = .193). The flow 30% VT increased in EFL (P = .043) and in NEFL (P = .001), but NEFL presented higher values (P = .006). There were correlations between Rtot and flow 30% VT during ERCC (r = −0.635, P = .003) and between Rinit and flow 30% VT during ERCC (r = −0.596, P = .006). There were no other associations between expiratory flows during ERCC and respiratory mechanics parameters.
Discussion
Even with lack of evidence, ERCC has been empirically used by physiotherapists for improving expiratory flows and therefore airway clearance.3 Our study showed that ERCC improves expiratory flow but has little effect on secretion removal and respiratory mechanics in mechanically ventilated patients with pulmonary infection. These results are in agreement with previous studies that found no benefits with ERCC in animal models8–10 and in mechanically ventilated patients.4,12
Mucus Clearance
In this study, mucus clearance was computed as sputum volume. Although measurement of the transport rate of mucus in the airway using a radioactive tracer technique is the most direct outcome parameter,5 this method is difficult to implement in critical care settings. Thus, quantification of expectorated mucus has been used as an important airway clearance marker in most physiotherapy studies including mechanically ventilated patients.12,20,25–28 For a better mechanistic approach, our mucus clearance results are discussed along with the following respiratory mechanics subitems.
Expiratory Flow Limitation
Air-flow transport depends mainly on the air-flow velocity, which is determined by the airway diameter and the intrapulmonary pressure created by the expiratory muscles (or by any thoracic compressive maneuver).5 During a forced expiration or a compressive maneuver, the transmural pressure might reduce the airway diameter, causing a disproportion between the driving pressure and the expiratory flow (ie, EFL). If the airway collapses, the downstream flow equals zero, and secretion removal is interrupted.6,29
Because ERCC is mechanically similar to a forced expiratory maneuver, it has the potential to cause EFL and peripheral airway closure. In our study, perhaps because all subjects were receiving mechanical ventilation with PEEP 5 cm H2O, only 6 subjects (30%) presented EFL during ERCC. It is likely that the protective mechanical effect of PEEP during the maneuver prevented the EFL in many subjects and contributed to the overall increase in PEF and flow 30% VT. As expected, this increase was more pronounced in NEFL subjects, suggesting that higher PEEP levels are necessary to stabilize the airway during ERCC in some patients. In this way, to increase the expiratory flow and prevent airway collapse during the maneuver, the PEEP level should be increased to the point at which there is no superposition between the baseline (current ventilation) and ERCC flow-volume loops observed on the ventilator display.
As the protective mechanical effect of PEEP is not present in spontaneous ventilated patients, it is likely that ERCC causes EFL and airway closure more frequently, mainly in patients with pulmonary obstructive diseases. However, it is impossible to predict in which patients ERCC will cause a dynamic compressive effect, which in theory can help in secretion removal, or airway collapse, which can interrupt airway clearance. On the basis of this premise, to remove peripheral secretions, the rationale of ERCC should include strategies aiming to avoid airway collapse, mainly in patients with reduced airway stability and/or functional residual capacity (eg, bed-ridden patients).
Respiratory System and Airway Resistance
We found no changes in Rtot and Rinit, in agreement with previous work.10,20,30,31 According to these studies, transitory bronchial constriction, variable secretion distribution patterns in patients' airways, mucociliary activity, and individualized response to the applied intervention could explain the unchanged respiratory resistance observed after the use of airway clearance techniques. Moreover, because of the greatest contribution of the central and intermediate airways to respiratory system resistance, if the secretions displace from the periphery to more proximal airways (but are not completely removed by suctioning), there will be an increase in these resistance parameters.32
We also found that in subjects with higher respiratory and airway resistance (Rtot and Rinit, respectively), the compressive maneuver was less effective in augmenting expiratory flow. This suggests that for more severely obstructed patients, a higher VT may add some benefit to ERCC in increasing expiratory flow.
Static and Effective Respiratory Compliance
Although Cst has been used by several authors to assess the effect of airway clearance techniques in mechanically ventilated patients,20,25–28 the only study evaluating ERCC as an isolated technique in humans used Ceff.4 The use of this mechanical variable made the interpretation of respiratory mechanics difficult because this parameter is influenced not only by the elastic properties of the respiratory system (which depend on the recruitment or de-recruitment of lung periphery), but also by its resistive and inhomogeneous components (which depend on other factors, such as the patterns of secretion distribution in the airways).17 Nevertheless, these authors also postulated that ERCC can cause any degree of pulmonary collapse, which is in agreement with the study of Martí et al,10 who found a reduction in Cst after ERCC in an animal model. In our study, Cst and Ceff did not change immediately after ERCC, but presented a small increase after a hyperinflation maneuver compared with CTRL. It is likely that ERCC promoted some peripheral airway clearance in association with a degree of pulmonary collapse (because of the compressive effect), so these events counterbalanced each other, resulting in an unchanged Cst in POST1. The subsequent hyperinflation maneuver re-inflated the collapsed areas,7 and the Cst values then became higher in ERCC (POST2). These positive effects in respiratory mechanics after only a hyperinflation maneuver point to a new possible recommendation when using ERCC, aiming to re-inflate any collapsed pulmonary areas. However, this recommendation is applicable only if future studies show clinically relevant benefits of ERCC in some context.
Our results cannot be extrapolated to other clinical settings because the patients were evaluated with a specific ventilatory mode and parameters. Indeed, the physiological and therapeutic consequences of chest physiotherapy techniques are greatly influenced by the ventilatory settings, as, for example, the role of PEEP in preventing airway and lung collapse. Additionally, because there are no favorable data on ERCC short-term effects in the current literature, we cannot expect a positive impact of this technique in clinically relevant outcomes, such as stay, weaning outcome, mortality, and incidence of ventilator-associated pneumonia. The only study on these outcomes applied ERCC along with manual hyperinflation, making it difficult to determine which of these two techniques was responsible for the improvement in the stay and time-to-weaning found by the authors.11
Regarding the limitations of the study, arterial blood gases were not recorded, and a blinded assessor could have done all measurements. Despite these limitations, we believe that our results add an important contribution to the field because we assessed the isolated clinical and physiological effects of ERCC (not associated with any other technique), which confirmed the negative results from previous animal and human studies. Moreover, in our study, we took special care to ensure that sputum production and respiratory mechanics reflected the effects of ERCC on lung periphery. In this way, before the interventions, all subjects were suctioned to remove the secretions from central airways, and measurements of respiratory mechanics included Cst, a recognized marker of peripheral airway clearance.33 We also suggested possible recommendations for this technique, such as the use of a hyperinflation maneuver after its application and flow-volume curve monitoring during thoracic compression to avoid airway collapse by setting an appropriate PEEP level.
Additional studies are necessary to evaluate the effects of ERCC in spontaneous ventilation, in specific diseases and respiratory mechanics conditions, and with different ventilatory modes and parameters. It is likely that other factors, such as compressive force magnitude, airway stability, and pulmonary volume at the onset of expiration, influence the effectiveness of ERCC. Additionally, for a better understanding of the underlying mechanisms of ERCC, it is important to consider not only the PEF, but also fluid mechanics principles, which determine mucus transport by air-liquid interaction in central and peripheral airways.
In conclusion, although ERCC increases expiratory flow, it has no clinically relevant effects in improving the sputum production and respiratory mechanics in hypersecretive mechanically ventilated patients. The maneuver can cause EFL in some patients.
Footnotes
- Correspondence: Fernando S Guimarães PT PhD, Programa de Mestrado em Ciências da Reabilitação, Praça das Nações, 34, Bonsucesso, Rio de Janeiro CEP 21041-021, Brazil. E-mail: fguimaraes_pg{at}yahoo.com.br.
The authors have disclosed no conflicts of interest.
- Copyright © 2014 by Daedalus Enterprises