Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
  • Log out
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleSymposium Papers

Aerosol Delivery to Ventilated Infant and Pediatric Patients

James B Fink
Respiratory Care June 2004, 49 (6) 653-665;
James B Fink
Aerogen Incorporated, Mountain View, California.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
  • Article
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

Infants have low tidal volume, vital capacity, and functional residual capacity, and short respiratory cycles (low I:E ratio), which result in a low residence time for aerosol particles and, thus, low pulmonary deposition of aerosol particles (<1% of the nominal dose), compared to adults (8–22%). Scintigraphy data suggest aerosol deposition of < 1% in both intubated and nonintubated infants. In vitro testing appears to overestimate pulmonary deposition, partly because in vitro testing does not account for exhaled aerosol. Animal models of infant ventilation tend to agree with data from human studies. However, though only a small percentage of the aerosol deposits in the lung, infants nevertheless receive considerably more aerosolized drug per kilogram of body weight than do adults. Efficient aerosol delivery to infants is challenging because of low deposition and high inter-patient and intra-patient variability, but existing systems can effectively delivery various aerosolized drugs, including bronchodilators, anti-inflammatories, and anti-infectives. Use of a nebulizer that has a low residual volume (of drug remaining in the device after nebulization) delivers up to 13%. Awareness of the variables that impact aerosol delivery efficiency can result in more effective treatment of mechanically ventilated infants.

  • aerosol
  • neonatal
  • pediatric
  • nebulizer
  • metered-dose inhaler

Footnotes

  • Correspondence: James B Fink MSc RRT FAARC, Aerogen Incorporated, 2071 Stierlin Court, Mountain View CA 94043, E-mail: jfink{at}aerogen.com.
  • Copyright © 2004 by Daedalus Enterprises Inc.
Previous
Back to top

In this issue

Respiratory Care: 49 (6)
Respiratory Care
Vol. 49, Issue 6
1 Jun 2004
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Aerosol Delivery to Ventilated Infant and Pediatric Patients
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Aerosol Delivery to Ventilated Infant and Pediatric Patients
James B Fink
Respiratory Care Jun 2004, 49 (6) 653-665;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Aerosol Delivery to Ventilated Infant and Pediatric Patients
James B Fink
Respiratory Care Jun 2004, 49 (6) 653-665;
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • aerosol
  • neonatal
  • Pediatric
  • nebulizer
  • metered-dose inhaler

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire