Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
  • Log out
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleOriginal Research

Albuterol Delivery via Intrapulmonary Percussive Ventilator and Jet Nebulizer in a Pediatric Ventilator Model

Ariel Berlinski and J Randy Willis
Respiratory Care December 2010, 55 (12) 1699-1704;
Ariel Berlinski
Arkansas Children's Hospital, Little Rock, Arkansas.
Pulmonology Section, Department of Pediatrics, University of Arkansas for Medical Sciences
Pediatric Aerosol Research Laboratory, Arkansas Children's Hospital Research Institute, Little Rock, Arkansas.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
J Randy Willis
Arkansas Children's Hospital, Little Rock, Arkansas.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

BACKGROUND: In-line administration of bronchodilators is widely used in pediatric patients receiving mechanical ventilation. We compared the amount of albuterol captured at the end of the endotracheal tube (ETT) with an intrapulmonary percussive ventilator (IPV) versus a Salter 8900 jet nebulizer placed in-line in a pediatric ventilator model, under various operating conditions. We hypothesized that the type of aerosol generator, tidal volume (VT), and position in the ventilator circuit would influence the albuterol delivery.

METHODS: We connected a ventilator to a heated-wire ventilator circuit (heated to 37°C), to a cuffed 5.5-mm inner-diameter ETT, to a lung model, and ran the ventilator at pediatric ventilation settings: pressure-regulated volume-control mode, respiratory rate 20 breaths/min, PEEP 5 cm H2O, FIO2 0.4, inspiratory time 0.75 s, inspiratory rise time 0.15 s, and flow-triggering at 3 L/min. We collected aerosol with a filter at the distal end of the ETT (ie, between the ETT and the lung model). We tested 3 IPV units run on central O2 at 50-PSI, with a drive pressure of 25 cm H2O, and 3 Salter 8900 units run on central O2 at 6 L/min. We diluted 5 mg of albuterol in saline, and nebulized 3 mL with the jet nebulizer and 10 mL with the IPV. We studied VT (100 mL vs 200 mL), position in the circuit (at the humidifier vs at the Y-piece), and the IPV's “easy” and “hard” percussion settings.

RESULTS: When positioned at the humidifier, the IPV delivered significantly less albuterol than the jet nebulizer (3.1–3.9-fold difference, P = .002). When the IPV was moved to the Y-piece, the albuterol delivery was similar to that of the jet nebulizer at either position. Neither increasing the VT nor increasing the IPV settings increased the albuterol delivery.

CONCLUSIONS: The IPV delivered less albuterol than the jet nebulizer when placed at the humidifier. IPV was equivalent to jet nebulizer when placed at the Y-piece. Doubling the VT did not increase aerosol delivery.

  • mechanical ventilation
  • albuterol
  • nebulizer
  • intrapulmonary percussive ventilator
  • IPV
  • position
  • pediatrics
  • aerosol

Footnotes

  • Correspondence: Ariel Berlinski MD, Department of Pediatrics, College of Medicine, University of Arkansas for Medical Sciences, 1 Children's Way, Little Rock AR 72202. E-mail: berlinskiariel{at}uams.edu.
  • Mr Willis presented a version of this paper at the 54th International Respiratory Congress of the American Association for Respiratory Care, held December 13-16, 2008, in Anaheim, California.

  • Dr Berlinski has disclosed relationships with B&B Medical Technologies, Gilead Sciences, Johnson & Johnson, MAP Pharmaceuticals, and Mpex Pharmaceuticals. Mr Willis has disclosed a relationship with B&B Medical Technologies. The Pediatric Aerosol Laboratory at Arkansas Children's Hospital Research Institute was partially established with support from the George Endowment for Asthma.

  • Copyright © 2010 by Daedalus Enterprises Inc.
PreviousNext
Back to top

In this issue

Respiratory Care: 55 (12)
Respiratory Care
Vol. 55, Issue 12
1 Dec 2010
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Albuterol Delivery via Intrapulmonary Percussive Ventilator and Jet Nebulizer in a Pediatric Ventilator Model
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Albuterol Delivery via Intrapulmonary Percussive Ventilator and Jet Nebulizer in a Pediatric Ventilator Model
Ariel Berlinski, J Randy Willis
Respiratory Care Dec 2010, 55 (12) 1699-1704;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Albuterol Delivery via Intrapulmonary Percussive Ventilator and Jet Nebulizer in a Pediatric Ventilator Model
Ariel Berlinski, J Randy Willis
Respiratory Care Dec 2010, 55 (12) 1699-1704;
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • Mechanical ventilation
  • albuterol
  • nebulizer
  • intrapulmonary percussive ventilator
  • IPV
  • position
  • pediatrics
  • aerosol

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire