Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
  • Log out
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleOriginal Research

Evaluation of Aerosol Generator Devices at 3 Locations in Humidified and Non-humidified Circuits During Adult Mechanical Ventilation

Arzu Ari, Hasan Areabi and James B Fink
Respiratory Care July 2010, 55 (7) 837-844;
Arzu Ari
Division of Respiratory Therapy, School of Health Professions, Georgia State University, Atlanta, Georgia.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Hasan Areabi
Division of Respiratory Therapy, School of Health Professions, Georgia State University, Atlanta, Georgia.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
James B Fink
Division of Respiratory Therapy, School of Health Professions, Georgia State University, Atlanta, Georgia.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

BACKGROUND: The position of the jet or ultrasonic nebulizer in the ventilator circuit impacts drug delivery during mechanical ventilation, but has not been extensively explored, and no study has examined all of the commonly used nebulizers.

METHODS: Drug delivery from jet, vibrating-mesh, and ultrasonic nebulizers and pressurized metered-dose inhaler (pMDI) with spacer was compared in a model of adult mechanical ventilation, with heated/humidified and non-humidified ventilator circuits. Albuterol sulfate was aerosolized at 3 circuit positions: (1) between the endotracheal tube and the Y-piece; (2) 15 cm from Y-piece; and (3) 15 cm from the ventilator, with each device (n = 3) using adult settings (tidal volume 500 mL, ramp flow pattern, 15 breaths/min, peak inspiratory flow 60 L/min, and PEEP 5 cm H2O). The drug deposited on an absolute filter distal to an 8.0-mm inner-diameter endotracheal tube was eluted and analyzed via spectrophotometry (276 nm), and is reported as mean ± SD percent of total nominal or emitted dose.

RESULTS: The vibrating-mesh nebulizer, ultrasonic nebulizer, and pMDI with spacer were most efficient in position 2 with both non-humidified (30.2 ± 1.0%, 24.7 ± 4.4%, and 27.8 ± 3.3%, respectively) and heated/humidified circuits (16.8 ± 2.6%, 16.5 ± 4.3%, and 17 ± 1.0%, respectively). In contrast, the jet nebulizer was most efficient in position 3 under both non-humidified (14.7 ± 1.5%) and heated/humidified (6.0 ± 0.1%) conditions. In positions 2 and 3, all devices delivered approximately 2-fold more drug under non-humidified than under heated/humidified conditions (P < .01). At position 1 only the pMDI delivered substantially more drug than with the non-humidified circuit.

CONCLUSION: During mechanical ventilation the optimal drug delivery efficiency depends on the aerosol generator, the ventilator circuit, and the aerosol generator position.

  • aerosols
  • jet nebulizer
  • vibrating-mesh nebulizer
  • ultrasonic nebulizer
  • metered-dose inhaler
  • pMDI
  • ventilator circuit
  • mechanical ventilation
  • heat
  • humidity
  • drug administration
  • aerosol drug deposition
  • nebulizers

Footnotes

  • Correspondence: Arzu Ari PhD RRT PT CPFT, Division of Respiratory Therapy, School of Health Professions, Georgia State University, PO Box 4019, Atlanta GA 30302-4019. E-mail: aari1{at}gsu.edu.
  • Dr Ari presented a version of this paper at the 53rd International Respiratory Congress of the American Association for Respiratory Care, held December 1-4, 2007, in Orlando, Florida.

  • Dr Fink has disclosed relationships with Aerogen, Aridis, Cubist, Dance Pharma, Kalobios, and Novartis. The other authors have disclosed no conflicts of interest.

  • See the Related Editorial on Page 942

  • Copyright © 2010 by Daedalus Enterprises Inc.
PreviousNext
Back to top

In this issue

Respiratory Care: 55 (7)
Respiratory Care
Vol. 55, Issue 7
1 Jul 2010
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evaluation of Aerosol Generator Devices at 3 Locations in Humidified and Non-humidified Circuits During Adult Mechanical Ventilation
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Evaluation of Aerosol Generator Devices at 3 Locations in Humidified and Non-humidified Circuits During Adult Mechanical Ventilation
Arzu Ari, Hasan Areabi, James B Fink
Respiratory Care Jul 2010, 55 (7) 837-844;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Evaluation of Aerosol Generator Devices at 3 Locations in Humidified and Non-humidified Circuits During Adult Mechanical Ventilation
Arzu Ari, Hasan Areabi, James B Fink
Respiratory Care Jul 2010, 55 (7) 837-844;
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • aerosols
  • jet nebulizer
  • vibrating-mesh nebulizer
  • ultrasonic nebulizer
  • metered-dose inhaler
  • pMDI
  • ventilator circuit
  • mechanical ventilation
  • heat
  • humidity
  • drug administration
  • aerosol drug deposition
  • nebulizers

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire