Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Coming Next Month
    • Archives
    • Most-Read Papers of 2021
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2022 Call for Abstracts
    • 2021 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Coming Next Month
    • Archives
    • Most-Read Papers of 2021
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2022 Call for Abstracts
    • 2021 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Case ReportCase Reports

The Velcro Mustache: A Potential Barrier to Effective Bag-and-Mask Ventilation in Neonates on Nasal CPAP: Two Case Reports

Sabah Helou, Howard J Birenbaum, Daniel Blue, Maria A Pane and Gregory Andre Marinkovich
Respiratory Care July 2011, 56 (7) 1040-1042; DOI: https://doi.org/10.4187/respcare.01048
Sabah Helou
Division of Neonatology, Department of Pediatrics, Greater Baltimore Medical Center, Baltimore, Maryland.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Howard J Birenbaum
Division of Neonatology, Department of Pediatrics, Greater Baltimore Medical Center, Baltimore, Maryland.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Daniel Blue
Division of Neonatology, Department of Pediatrics, Greater Baltimore Medical Center, Baltimore, Maryland.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Maria A Pane
Division of Neonatology, Department of Pediatrics, Greater Baltimore Medical Center, Baltimore, Maryland.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gregory Andre Marinkovich
Division of Neonatology, Department of Pediatrics, Greater Baltimore Medical Center, Baltimore, Maryland.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Hudson prongs (Hudson RCI, Teleflex Medical, Research Triangle Park, North Carolina) (a device to deliver nasal continuous positive airway pressure) are often secured with a “Velcro mustache” in neonatal intensive care units. We report 2 premature infants who required bag-and-mask ventilation while on Hudson prongs secured with a Velcro mustache. Effective ventilation was achieved only after removing the Velcro mustache.

  • Hudson prongs
  • Velcro mustache
  • continuous positive airway pressure
  • CPAP
  • neonate
  • quality improvement

Introduction

Acute events that require resuscitation are not uncommon in the neonatal intensive care unit. Bag-and-mask ventilation is an effective and common procedure in infants who have poor respiratory effort and require resuscitation. We recently cared for 2 premature infants who required bag-and-mask ventilation while receiving continuous positive airway pressure (CPAP) via Hudson prongs (Hudson RCI, Teleflex Medical, Research Triangle Park, North Carolina) secured with a Velcro mustache (a strip of Velcro tape placed across the baby's upper lip to secure the Hudson prongs in place, [Figs. 1 and 2]). Bag-and-mask ventilation was ineffective because of the Velcro mustache.

Fig. 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.

Velcro mustache.

Fig. 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.

Hudson prong assembly.

Case Report 1

This premature infant was the second of twins delivered at 24 weeks gestation, and weighed 630 g. His hospital course was complicated by respiratory distress syndrome, bronchopulmonary dysplasia, bowel perforation that required surgical intervention, and a patent ductus arteriosus that required ligation. At 3 months of age, he was clinically stable, tolerating gavage feedings, weighed 1,790 g, and was being managed on Hudson prongs, with bubble CPAP at 5 cm water, and 28% oxygen. In the early evening he had an episode of bradycardia while having his nasopharynx suctioned. With poor response to stimulation, he received bag-and-mask ventilation with a disposable infant resuscitation bag-and-mask (Spur II Infant Resuscitator, Ambu, Glen Burnie, Maryland) and an appropriate-size, anatomically shaped, cushioned face mask. Seconds into the resuscitation, we realized that it was not possible to achieve a good seal and generate effective ventilation. His chest did not move, despite repositioning and assuring a clear airway. We attributed the failure to achieve a good seal to the Velcro mustache, which had been placed to appropriately position the Hudson prongs. Removing the Velcro mustache allowed an effective mask/face seal.

Case Report 2

This infant was a premature boy delivered at 27 weeks gestation, with a birth weight of 720 g. He was on Hudson prongs and bubble CPAP for respiratory distress syndrome. On the third day of life, while on CPAP, he required bag-and-mask ventilation for an episode of apnea associated with bradycardia, oxygen desaturation, and unresponsiveness to stimulation. As in the first patient, we found that effective ventilation could not be achieved with the bag-and-mask (Spur II Infant Resuscitator, Ambu, Glen Burnie, Maryland) and an appropriate-size, anatomically shaped, cushioned face mask, with the Velcro mustache in place. As with the other patient, effective ventilation with a good mask/face seal was obtained after the Velcro mustache was removed.

Discussion

In an attempt to minimize the risk of lung injury, CPAP via nasal prongs is increasingly used as the first-line treatment for respiratory distress syndrome.1–5 CPAP has been used for the treatment of lung disease in premature infants for over 30 years.6 The benefits, potential complications, and required special nursing techniques for nasal CPAP are well described in the literature.1–3,7,8

In our 30-bed, level III-B neonatal intensive care unit, we had been using CPAP prongs from Fisher & Paykel Healthcare (Auckland, New Zealand). As part of our quality-improvement program we monitored the complications associated with CPAP, specifically the incidence of nasal injuries due to pressure on the nasal septum, and septal necrosis. To minimize the risk of nasal injuries, we recently began using Hudson prongs, which are commonly used in many hospitals, such as Columbia Presbyterian's Babies Hospital. Figures 1 and 2 show how we apply Hudson prongs. Although not described in the product's directions for use, a common way of securing Hudson prongs is with a Velcro mustache placed on the infant's face to which the prong assembly is attached.1 The mustache helps keep the prongs in good position and thus avoids applying pressure from the bridge of the prongs to the nasal septum. To protect the skin we place a layer of dressing (Duoderm, ConvaTec, Skillman, New Jersey, or Tegaderm, 3M, St Paul, Minnesota) above the upper lip before attaching the Velcro mustache.

To test our observation that the Velcro mustache prevented a good mask/face seal, we used, under various conditions, a neonatal manikin and a T-piece resuscitator (Neopuff, Fisher & Paykel Healthcare, Auckland, New Zealand) that includes a manometer, which allows easy assessment of peak inspiratory pressure (PIP), PEEP, and CPAP.

We first tested the ability to provide CPAP levels of 5, 7, 10, 12, and 16 cm H2O. Without the Velcro mustache we easily achieved the desired CPAP with a cushioned mask on the manikin's face. With the Velcro mustache, all attempts failed to reach the desired CPAP, because of an ineffective seal.

We subsequently tested the ability to provide pre-set PIP levels of 15, 20, and 25 cm H2O and a pre-set PEEP of 5 cm H2O. Without the Velcro mustache we easily generated the desired PIP, but with the Velcro mustache all attempts failed to reach and hold a steady PIP or PEEP, despite exerting substantial pressure on the cushioned mask. The manometer never exceeded 4 cm H2O for PIP, and 2 cm H2O for PEEP.

We had been unaware that a Velcro mustache might interfere with obtaining a good mask/face seal during bag-and-mask ventilation, and we found no mention of this problem in the literature. We submit these case reports in the interest of sharing our experience with other neonatal intensive care units using or contemplating a Velcro mustache to fix nasal CPAP prongs. Removing the Velcro mustache is essential for obtaining an effective seal during bag-and-mask ventilation. We find that the easiest way to remove the Velcro mustache is by peeling off the Duoderm or Tegaderm dressing to which it is attached.

Footnotes

  • Correspondence: Howard J Birenbaum MD, Division of Neonatology, Department of Pediatrics, Greater Baltimore Medical Center, 6701 North Charles Street, Baltimore MD 21204. E-mail: hbirenba{at}gbmc.org.
  • The authors have disclosed no conflicts of interest.

  • Copyright © 2011 by Daedalus Enterprises Inc.

References

  1. 1.↵
    1. Ammari A,
    2. Kashlan F,
    3. Ezzedeen F,
    4. Al-Zahrani A,
    5. Kaawas J,
    6. Majeed-Saidan MA
    . Bubble nasal CPAP manual. 2005. http://earlybubblecpap.com/downloads/CPAP%20Educational%20Files/CPAP_Manual.pdf. Accessed May 11, 2011.
  2. 2.
    1. Polin RA,
    2. Sahni R
    . Newer experience with CPAP. Semin Neonatol 2002;7(5):379–389.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. De Klerk AM,
    2. De Klerk RK
    . Nasal continuous positive airway pressure and outcomes of preterm infants. J Paediatr Child Health 2001;37(2):161–167.
    OpenUrlCrossRefPubMed
  4. 4.
    1. Van Marter LJ,
    2. Allred EN,
    3. Pagano M,
    4. Sanocka U,
    5. Parad R,
    6. Moore M,
    7. et al
    . Do clinical markers of barotrauma and oxygen toxicity explain interhospital variation in rates of chronic lung disease? Pediatrics 2000;105(6):1194–1201.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Birenbaum HJ,
    2. Dentry A,
    3. Cirelli J,
    4. Helou S,
    5. Pane MA,
    6. Starr K,
    7. et al
    . Reduction in the incidence of chronic lung disease in very low birth weight infants: results of a quality improvement process in a tertiary level neonatal intensive care unit. Pediatrics 2009;123(1):44–50.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Gregory GA,
    2. Kitterman JA,
    3. Phibbs RH,
    4. Tooley WH,
    5. Hamilton WK
    . Treatment of the idiopathic respiratory distress syndrome with continuous positive airway pressure. N Engl J Med 1971;284(24):1333–1340.
    OpenUrlPubMed
  7. 7.↵
    1. Bonner KM,
    2. Mainous RO
    . The nursing care of the infant receiving bubble CPAP therapy. Adv Neonatal Care 2008;8(2):78–95.
    OpenUrlPubMed
  8. 8.↵
    1. Squires AJ,
    2. Hyndman M
    . Prevention of nasal injuries secondary to NCPAP application in the ELBW infant. Neonatal Netw 2009;28(1):13–27.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

Respiratory Care: 56 (7)
Respiratory Care
Vol. 56, Issue 7
1 Jul 2011
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Velcro Mustache: A Potential Barrier to Effective Bag-and-Mask Ventilation in Neonates on Nasal CPAP: Two Case Reports
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
The Velcro Mustache: A Potential Barrier to Effective Bag-and-Mask Ventilation in Neonates on Nasal CPAP: Two Case Reports
Sabah Helou, Howard J Birenbaum, Daniel Blue, Maria A Pane, Gregory Andre Marinkovich
Respiratory Care Jul 2011, 56 (7) 1040-1042; DOI: 10.4187/respcare.01048

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
The Velcro Mustache: A Potential Barrier to Effective Bag-and-Mask Ventilation in Neonates on Nasal CPAP: Two Case Reports
Sabah Helou, Howard J Birenbaum, Daniel Blue, Maria A Pane, Gregory Andre Marinkovich
Respiratory Care Jul 2011, 56 (7) 1040-1042; DOI: 10.4187/respcare.01048
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Case Report 1
    • Case Report 2
    • Discussion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • Hudson prongs
  • Velcro mustache
  • Continuous Positive Airway Pressure
  • CPAP
  • neonate
  • quality improvement

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board
  • Reprints/Permissions

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire