Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Coming Next Month
    • Archives
    • Most-Read Papers of 2021
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2022 Call for Abstracts
    • 2021 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
  • Log out
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Coming Next Month
    • Archives
    • Most-Read Papers of 2021
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2022 Call for Abstracts
    • 2021 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research Article27th Annual New Horizons Symposium: Ventilator Liberation

Evidence-Based Assessments in the Ventilator Discontinuation Process

Neil R MacIntyre
Respiratory Care October 2012, 57 (10) 1611-1618; DOI: https://doi.org/10.4187/respcare.02055
Neil R MacIntyre
Division of Pulmonary and Critical Care Medicine, Duke University Medical Center, Durham, North Carolina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

The ventilator discontinuation process is an essential component of overall ventilator management. Undue delay leads to excess stay, iatrogenic lung injury, unnecessary sedation, and even higher mortality. On the other hand, premature withdrawal can lead to muscle fatigue, dangerous gas exchange impairment, loss of airway protection, and also a higher mortality. An evidence-based task force has recommended a daily discontinuation assessment and management process for most ICU patients requiring at least 24 hours of mechanical ventilator support. This process focuses on assessments on the causes for ventilator dependence, assessments for evidence of disease stability/reversal, use of regular spontaneous breathing trials (SBTs) as the primary assessment tool for ventilator discontinuation potential, use of separate assessments to evaluate the need for an artificial airway in patients tolerating the SBT, and the use of comfortable, interactive ventilator modes (that do not need to be “weaned”) in between regular SBTs. More recent developments have focused on the utility of computer decision support to guide these processes and the importance of linking sedation reduction protocols to ventilator discontinuation protocols. These guidelines are standing the test of time, and practice patterns are evolving in accordance with them. Nevertheless, there is still room for improvement and need for further clinical studies, especially in the patient requiring prolonged mechanical ventilation.

  • mechanical ventilation
  • discontinuation
  • iatrogenic
  • lung injury
  • sedation
  • mortality
  • ventilator dependence
  • spontaneous breathing trial
  • SBT
  • ventilator discontinuation
  • weaning

Introduction

In the ICU, as respiratory failure stabilizes and begins to reverse, clinical attention should shift to the ventilator withdrawal process. These discontinuation assessments are critical for optimal outcomes. Failure to recognize discontinuation potential will result in undue delay in ventilator withdrawal, leading to increased stay, higher costs, excessive sedation needs, longer exposure to potentially “toxic” airway pressures/volumes, and increased infection risks.1–4 On the other hand, discontinuation assessments leading to overly aggressive ventilator withdrawal attempts carry their own hazards. Specifically, premature ventilator withdrawal can lead to airway loss, compromised gas exchange, aspiration, and inspiratory muscle fatigue.5,6 Indeed, a failed extubation is associated with an 8-fold higher odds ratio for nosocomial pneumonia and a 6-fold to 12-fold increased mortality risk.7,8

The clinical challenge then is to balance aggressiveness with safety. A common quality indicator addressing this balance is the reintubation rate (ie, patients needing reintubation/total number of patients extubated). A value too low suggests unnecessary delays in ventilator removal; a value too high suggests inappropriate aggressiveness in support removal. Reported reintubation rates range from 4–23% for different ICU populations, and may be as high as 33% in patients with mental status changes and neurologic impairment.3,8–15 Although never subjected to rigorous cost/benefit analyses, reintubation rates of 5–20% are generally considered reasonable.

The remainder of this paper will review the evidence supporting current recommendations for ventilator discontinuation assessments in the ICU. Importantly, these assessments are of 2 fundamental types. One focuses on the need for mechanical ventilation; the other focuses on the need for an artificial airway. What will not be discussed is the concept of “weaning,” a process of gradual support reduction using various partial support modes (eg, pressure support or intermittent mandatory ventilation). These have never been shown to be superior to the daily formal assessments for discontinuation described below.1,16 Also not discussed is the approach to ventilator discontinuation in patients requiring prolonged mechanical ventilation. Prolonged mechanical ventilation patients generally are defined as requiring ventilatory support for > 21 days, usually with a tracheostomy in place. Excellent reviews on the management of the prolonged mechanical ventilation population can be found elsewhere.1,17,18

Analyzing the Evidence Base for the Ventilator Discontinuation Process in the ICU

The important clinical questions facing the clinician in the ICU are: When can efforts to discontinue ventilation be initiated? What assessment strategies will best identify the patient who is ready for ventilator discontinuation? When should extubation be carried out? Evidence to answer these questions comes largely from observational studies in which a certain parameter (or set of parameters) is compared in a group of patients who either successfully or unsuccessfully have been removed from the ventilator. The general goal of these studies is to find “predictors” of outcome.

Evaluating results from these types of studies can be difficult for several reasons. First, the “aggressiveness” of the clinician/investigator's discontinuation philosophy needs to be understood, as it will affect the performance of a given predictor. Second, patients are recruited into these studies because investigators believe there is some reasonable chance of success for ventilator discontinuation. These “entry” criteria often include some form of clinical judgment or intuition, making results from one study difficult to compare to another. Third, methodological problems inherent to observational studies include different measurement techniques of a given parameter from study to study, large coefficients of variation of a given parameter with repeated measurements from study to study, and different patient populations (eg, long-term vs short-term ventilator dependence).19 Fourth, assessed outcomes differ from study to study. Some investigators have examined successful tolerance of a spontaneous breathing trial (SBT), others have used permanent discontinuation of the ventilator, and others have combined successful discontinuation and extubation. In addition, different studies use different durations of ventilator discontinuation or extubation to define success or failure. Although 24 to 48 hours of unassisted breathing often is considered to define the successful discontinuation of ventilator support, many studies use shorter time periods to indicate success and often do not report subsequent reintubation rates or the need to reinstitute mechanical ventilatory support.

Developing Evidence-Based Guidelines: 2001–2002

In 1999, McMaster University, funded by a large grant from the United States Agency for Health Care Policy Research, published a comprehensive evidence-based review of the world's literature pertaining to ventilator discontinuation (over 5,000 publications).20 This report found evidence in the literature supporting a possible role for 66 specific measurements as predictors of successful ventilator discontinuation. To evaluate the role of these parameters, the McMaster University report used likelihood ratios (LRs), an expression of the odds that a given test result will be present in a patient with a given condition, compared to a patient without the condition. An LR > 1 indicates that the probability of success increases, while values < 1 indicate that the probability of failure increases. LRs between 0.5 and 2 indicate that a discontinuation parameter is associated with only small, clinically unimportant changes in the post-test probability of success or failure. In contrast, LRs from 2 to 5 and from 0.3 to 0.5 correlate with small but potentially important changes in probability, while ratios of 5 to 10 or 0.1 to 0.3 correlate with more clinically important changes in probability. Ratios of > 10 or < 0.1 correlate with very large changes in probability. With this approach, the McMaster group identified 8 parameters that had consistently significant LRs to predict successful ventilator discontinuation in several studies. Some of these measurements are made while the patient is still receiving ventilatory support; others require an assessment during a brief period of spontaneous breathing. These parameters, their threshold values, and the range of reported LRs are given in Table 1. It should be noted that despite the statistical significance of these parameters, the generally low LRs indicate that the clinical applicability of these parameters alone to individual patients is low.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1.

Eight Parameters Found in the McMaster Review20 With Significant Likelihood Ratios for Predicting Ventilator Discontinuation Success*

Following the publication of the McMaster report, the American College of Chest Physicians (ACCP), the Society for Critical Care Medicine (SCCM), and the American Association for Respiratory Care (AARC) assembled a task force to issue evidence-based guidelines for clinicians to follow in the ventilator discontinuation process.1 These guidelines were based largely on the McMaster review of the clinical evidence base, but, by necessity, also incorporated evidence from basic science work, lung model studies, animal studies, non-outcome-based human studies, and even “expert opinion” to fill in the gaps in the clinical evidence base. In the end, 12 guidelines were described, 7 of which relate to the ventilator discontinuation process in the ICU (Table 2). These are reviewed in more detail below.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 2.

Recommendations Regarding Management of Mechanically Ventilated ICU Patients From the ACCP/SCCM/AARC Ventilator Discontinuation Evidence Based Guidelines Task Force1*

The Evidence-Based Formal Discontinuation Assessment Guidelines

The first step in the discontinuation process is to assess the status and trajectory of underlying cause(s) for mechanical ventilatory support in a given patient (see Table 2, Recommendation 1). Determining which factor or factors may be involved in a given patient requires both clinical awareness of these factors as well as focused clinical assessments. Among the more important factors impacting ventilator dependence are neurologic abnormalities affecting the brainstem ventilatory control system, respiratory muscle capability/mechanical load imbalances, impaired ventilation-perfusion matching in the lungs, abnormal cardiac function, lung edema, metabolic derangements (eg, glucose homeostasis and adrenal function), ultimate oxygen delivery, and even psychological factors. The search for the underlying causes for ventilator dependence may be especially important in “difficult to discontinue” patients, as previously unrecognized, but reversible, conditions may be discovered.21

Importantly, iatrogenic factors, such as excessive sedation use, inappropriate ventilator settings causing lung injury and/or discomfort, inappropriate fluid management, inadequate nutrition, and lack of patient physical activity, may also contribute to ventilator dependence. And, of course, a failure to recognize ventilator discontinuation potential will also lead to iatrogenic ventilator dependence.

The criteria used by clinicians to define disease “reversal,” however, have been neither defined nor prospectively evaluated in a randomized controlled trial. Rather, various combinations of subjective assessment and objective criteria (eg, usually gas exchange improvement, mental status improvement, neuromuscular function assessments, and radiographic signs) that may serve as surrogate markers of recovery have been employed (see Table 2, Recommendation 2).3,9–11,13,14,22 It should be noted, however, that some patients who have never met one or more of these criteria still have been shown to be capable of eventual liberation from the ventilator.11

Clinical assessments of the status of the patient's respiratory failure described above are usually not enough to make decisions on the discontinuation of support. Indeed, in 2 large trials,13,14 despite the presence of apparent disease stability/reversal, the managing clinicians did not recognize that discontinuation was feasible in almost two thirds of the subjects. Thus, the conclusion is that some evidence of “clinical” stability/reversal is a key first step in assessing for discontinuation potential, but that a more focused assessment is needed before deciding to continue or discontinue ventilatory support.

The ACCP/SCCM/AARC guidelines (see Table 2, Recommendation 3) state that this formal assessment be an SBT. This is based on the very strong evidence that, although assessments that are performed while a patient is receiving substantial ventilatory support or during a brief period of spontaneous breathing can yield important information about discontinuation potential (see Table 1), assessments that are performed during a formal, carefully monitored SBT appear to provide the most useful information to guide clinical decision making regarding discontinuation.1 In concept, the SBT should be expected to perform well, as it is the most direct way to assess a patient's performance without ventilatory support. Multiple studies have found that patients tolerant of SBTs were found to have successful discontinuations at least 77% of the time.1,3,9,13,15,20,23 However, because patients failing the SBTs in these studies were not systematically removed from ventilatory support, the ability of a failed SBT to predict the need for ventilator dependence (ie, negative predictive value) cannot be formally assessed. Indeed, it is conceivable that iatrogenic factors such as endotracheal tube discomfort or demand-valve insensitivity/unresponsiveness, rather than true ventilator dependence, caused the failure of the SBT in at least some of these patients.3,15,24–27 Thus, it is unclear how many patients who are unable to tolerate an SBT would still be able to tolerate long-term ventilator discontinuation. Although the number is likely to be small, it is probably not zero, and this needs to be considered when dealing with patients who repeatedly fail an SBT.

The criteria used to define SBT “tolerance” are often integrated indexes, since, as noted above, single parameters alone perform so poorly. These integrated indexes usually include several physiologic parameters as well as clinical judgment, incorporating such difficult-to-quantify factors as “anxiety,” “discomfort,” and “clinical appearance.” Interestingly, in the 11 years since the publication of the original ACCP/SCCM/AARC guidelines, the criteria to assess SBT success/failure remained largely unchanged, essentially an integrated index of clinical assessments that do not rely on rigid numbers. Indeed, one important recent study addressing this issue showed clearly that the use of a rigid threshold of the ratio of respiratory frequency (f) to tidal volume (VT) of < 105 to define SBT success in fact slowed the discontinuation process.25 This observation has implications both for written management protocols as well as computer driven protocols.

The evidence is strong supporting the recommendation that an SBT should be at least 30 min but no longer than 120 min to allow proper assessment of ventilator discontinuation potential.1 This means that clinicians should wait at least 30 min to assure SBT tolerance but terminate the trial at 120 min if SBT tolerance is still unclear. There is evidence that the detrimental effects of ventilator muscle overload, if it is going to occur, often occur early in the SBT.3,15,26,27 Thus, the initial few minutes of an SBT should be monitored closely before a decision is made to continue (this is often referred to as the “screening” phase of an SBT).

Controversy exists on the “best” technique used to do the SBT. Options include a simple “T-piece” where only supplemental O2 is supplied at the proximal end of the endotracheal tube; setting the ventilator to a CPAP level equivalent to the previous PEEP setting; or setting a low level of assistance (eg, pressure support of 5–8 cm H2O or the use of “automatic” tube or airway compensation). The T-piece approach comes closest to mimicking the situation the patient will experience when extubated, and it is recommended by some for maximizing the specificity of the test (ie, lowest number of false positives). However, because the endotracheal tube is still present with its associated discomfort, the sensitivity of the SBT (ie, detecting true positives) may be somewhat compromised. In contrast, supplying a low level of inspiratory and/or expiratory pressure may hide a patient's inability to tolerate complete ventilator removal (excessive false positive tests), although it may relieve some of the iatrogenic discomfort of the endotracheal tube (fewer false negative tests). In large population studies, all 3 approaches appear to perform well, but the T-piece approach might be considered if there is concern about borderline SBT performance with other techniques or there is concern about the potential effects from a loss of PEEP.9,28–32

A potential concern about the SBT is safety. Although unnecessary prolongation of a failing SBT conceivably could precipitate muscle fatigue, hemodynamic instability, discomfort, or worsened gas exchange,33–37 there are really no data showing that SBTs contribute to any adverse outcomes if terminated promptly when failure is recognized. Indeed, in a cohort of > 1,000 patients in whom SBTs were routinely administered and properly monitored as part of a protocol, only one adverse event was thought to be even possibly associated with the SBT.11

While ICU patients who are judged tolerant of the SBT should move on to assessments of the need for continued use of the artificial airway (see below), the patient who is judged not tolerant of the SBT requires a different approach. In these patients, Table 2, Recommendations 5 and 6 indicate 3 courses of action. First, a careful search once again should be undertaken for ongoing (and potentially reversible) causes of ventilatory dependence. Second, a comfortable interactive form of ventilatory support should be provided that encourages respiratory muscle activity but does not overload muscles nor compromise gas exchange. Importantly, there are few (if any) data demonstrating that attempts to “wean” this support rather than keep it constant are beneficial.16 Third, every 24 hours the patient should be reassessed for another SBT. Importantly, all of these procedures can be carried out through protocols run by skilled clinicians (eg, respiratory therapists) (see Table 2, Recommendation 8).11,22

Since the publication of the original ACCP/SCCM/AARC guidelines, 2 important developments have occurred that build on the SBT approach. The first has been the application of computer driven assessments and clinician feedback tools that remind clinicians when SBTs are needed.38,39 Importantly, the benefits of these computer driven protocols appear to be a result of aggressive use of SBTs rather than any ventilator manipulation strategy.16 Second, and perhaps more importantly, has been the linkage of the SBT strategy to a sedation optimization strategy.40 As noted above, excessive sedation use has been recognized for years to be a barrier to effective SBT performance and efficient ventilator withdrawal. Optimizing patient-ventilator synchrony with appropriate ventilator settings can help minimize sedation use, but several recent studies have emphasized that focused protocols aimed at reducing sedation usage further can add to this. Indeed, the concept of routine “spontaneous awakening trials” and routine sedation cessation trials, coupled with routine SBTs, can markedly accelerate the ventilator withdrawal process.40

Assessing the Need for an Artificial Airway

Once a patient has been deemed to no longer need mechanical ventilatory support (or perhaps is deemed a candidate for noninvasive ventilation, as described elsewhere),41 attention then turns to the assessments of the need for the artificial airway (see Table 2, Recommendation 4). Extubation failure can occur for reasons distinct from those that cause discontinuation failure. Examples include upper-airway obstruction or the inability to protect the airway and to clear secretions.

The risk of post extubation upper-airway obstruction increases with the duration of mechanical ventilation, female sex, trauma, and repeated or traumatic intubation.3 The detection of an air leak during mechanical ventilation when the endotracheal tube balloon is deflated can be used to assess the patency of the upper airway (cuff leak test).42 In a study of medical patients, a cuff leak of < 110 mL (ie, average of 3 values on 6 consecutive breaths) measured during assist control ventilation within 24 hours of extubation identified patients at high risk for post-extubation stridor.43 Although others have not confirmed the utility of the cuff leak test for predicting post-extubation stridor,44 many patients who develop this can be treated with steroids and/or epinephrine (and possibly with noninvasive ventilation and/or heliox) and do not necessarily need to be reintubated. Steroids and/or epinephrine also could be used 24 hours prior to extubation in patients with low cuff leak values. It is also important to note that a low value for cuff leak may actually be due to encrusted secretions around the tube rather than to a narrowed upper airway.

The capacity to protect the airway and to expel secretions with an effective cough would seem to be vital for extubation success, although specific data supporting this concept are few. Airway assessments generally include noting the quality of cough with airway suctioning, the absence of “excessive” secretions, or the frequency of airway suctioning (eg, every 2 h or more).3,45,46 One approach uses an “airway care score” that semi-quantitatively assesses cough; gag; suctioning frequency; and sputum quantity, viscosity, and character; and that predicts extubation outcomes.4 Peak cough flows of > 160 L/min predict successful translaryngeal extubation or tracheostomy tube decannulation in neuromuscular or spinal cord-injured patients.47 Cough velocities of 0.5–1.0 L/s have also been shown in other studies to be compatible with successful extubation.48

The importance of intact cognitive function on extubation success is controversial. Successful extubations have been reported in a select group of brain-injured, comatose patients who were judged to be capable of protecting their airways.4 However, it is difficult to extrapolate this experience to more typical ICU patients, and many would argue that some capability of the patient to interact with the care team should be present before the removal of an artificial airway. Nevertheless, a review of the literature suggests that a Glasgow coma score above 8 is compatible with successful extubation, provided that adequate airway protection capabilities exist.49

How Has the Evolving Evidence Base Impacted Clinical Practice and Outcomes?

It has been over a decade since the first comprehensive set of evidence-based guidelines for the ventilator discontinuation process was issued.1 The most interesting assessments of the impact of these guidelines were 2 re-analyses of a large observational study from Europe involving 4,559 mechanically ventilated patients from 349 ICUs in 2004.50 In the first re-analysis51 the use of SBTs as the first assessment technique was found to increase from 58% to 62% from a similar survey in 1998 (P = .09). In contrast, discontinuation strategies using gradual support reductions switched significantly from synchronized intermittent mandatory ventilation (SIMV) or SIMV + pressure support from 11% and 26%, respectively, in 1998, to 1.6% and 15%, respectively, in 2004 (P < .001). Importantly, time devoted to the discontinuation process decreased from 50% to 40% of total ventilation time over the same period (P < .001).

In the second re-analysis,52 a newly described classification system of discontinuation difficulty was used: “Simple” (ventilator discontinued after the first assessment); “Difficult” (ventilator discontinued from 2–7 d after initial assessment); and “Prolonged” (ventilator discontinued in > 7 d after initial assessment). In this re-analysis 2,714 patients were successfully discontinued over the 28 day study period.53 Fifty-five percent were simple discontinuation; 39% were difficult discontinuation; and 6% were prolonged discontinuation. Of interest is that SBTs were used 82% of the time in the simple discontinuation patients but only 47% and 38% of the time in the difficult and prolonged discontinuation patients, respectively. The remaining patients were “weaned” with gradual support reduction strategies, usually stand alone pressure support but also SIMV + pressure support. An unanswered question is whether the lower use of SBTs in the difficult/prolonged discontinuation patients contributed to the need for longer periods of support.16 Not surprisingly, patients needing prolonged discontinuation processes were sicker, had longer stay, and had higher mortality than the simple discontinuation patients.

Taken together, these data suggest that clinical use of SBTs is commonplace and gradually increasing, especially in patients judged to be clinically ready for discontinuation. However, there still appears to be a persistent aversion to SBTs in the majority of patients about whom clinicians have concerns. This may not be optimal, and, indeed, the evidence would suggest that patients should not be labeled difficult or prolonged discontinuation problems until they have failed more than one SBT. Even in these patients, subsequent SBTs would still seem appropriate, although attempts at these might be delayed until improvement in the underlying disease processes occurs.1,5 As noted above, the additional role of gradual support reduction strategies in these patients remains unsupported by evidence (especially modes involving SIMV), but this clearly needs more study.

Summary

The ventilator discontinuation process is an essential component of overall ventilator management. Undue delay leads to excess stay, iatrogenic lung injury, unnecessary sedation, and even higher mortality. On the other hand, premature withdrawal can lead to muscle fatigue, dangerous gas exchange impairment, loss of airway protection, and also a higher mortality.

An evidence-based task force has recommended a daily assessment process for most ICU patients requiring at least 24 hours of mechanical ventilator support:

  1. Consider a patient a candidate for withdrawal if:

    • The lung injury is stable/resolving

    • The gas exchange is adequate with low PEEP/FIO2 requirements

    • Hemodynamics are stable without a need for pressors, and

    • There is the capability to initiate spontaneous breaths

  2. In these patients, perform an SBT (using T-piece, CPAP, or 5–8 cm H2O pressure support) for 30–120 min. Assessments should include the ventilatory pattern, gas exchange, hemodynamics, and comfort. Patients “passing” this trial should be considered for ventilator withdrawal.

  3. In patients passing the SBT, separate assessments are required to determine if the artificial airway can be removed. These involve the evaluation of cough strength, suctioning frequency, and, to a certain extent, the ability to follow commands.

  4. In patients failing the SBT, careful reevaluation of the need(s) for ongoing ventilatory support should be coupled with a daily reassessment for the appropriateness of repeat SBTs. Ventilatory support between SBTs should be comfortable interactive support that does not necessarily have to be “weaned.”

  5. All of these efforts should be coupled with aggressive strategies to reduce sedation, ideally conducted with written or computerized protocols.

The ACCP/SCCM/AARC guidelines stating these principles are standing the test of time, and practice patterns are evolving in accordance with them. Nevertheless, there is still room for improvement and need for further clinical studies, especially in the patient requiring prolonged mechanical ventilation.

Footnotes

  • Correspondence: Neil R MacIntyre MD FAARC, Division of Pulmonary and Critical Care Medicine, Duke University Hospital, Box 3911, Durham NC 27710. E-mail: neil.macintyre{at}duke.edu.
  • Dr MacIntyre presented a version of this paper at the New Horizons Symposium, “The Ventilator Liberation Process: A Fresh Look at the Evidence,” at the AARC Congress 2011, held November 5–8, 2011, in Tampa, Florida.

  • Dr MacIntyre has disclosed relationships with CareFusion, Trudell Medical, and Breathe Technology.

  • Copyright © 2012 by Daedalus Enterprises Inc.

References

  1. 1.↵
    1. MacIntyre NR,
    2. Cook DJ,
    3. Ely EW Jr.,
    4. Epstein SK,
    5. Fink JB,
    6. Heffner JE,
    7. et al
    . Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians, the American Association for Respiratory Care, and the American College of Critical Care Medicine. Chest 2001;120(Suppl):375S–395S. Also in: Respir Care 2002;47(1):69-90.
    OpenUrlCrossRefPubMed
  2. 2.
    1. Ely EW,
    2. Baker AM,
    3. Dunagan DP,
    4. Burke HL,
    5. Smith AC,
    6. Kelly PT,
    7. et al
    . Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously. N Engl J Med 1996;335(25):1864–1869.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Fagon JY,
    2. Chastre J,
    3. Hance AJ,
    4. Montravers P,
    5. Novara A,
    6. Gibert C
    . Nosocomial pneumonia in ventilated patients: a cohort study evaluating attributable mortality and hospital stay. Am J Mod 1993;94(3):281–288.
    OpenUrl
  4. 4.↵
    1. Coplin WM,
    2. Pierson DJ,
    3. Cooley KD,
    4. Newell DW,
    5. Rubenfeld GD
    . Implications of extubation delay in brain injured patients meeting standard weaning criteria, Am J Respir Crit Care Med 2000;161(5):1530–1536.
    OpenUrl
  5. 5.↵
    1. Tobin MJ,
    2. Guenther SM,
    3. Perez W,
    4. Lodato RF,
    5. Mador MJ,
    6. Allen SF,
    7. Dantzker DR
    . Konno-Mead analysis of rib cage-abdominal motion during successful and unsuccessful trials of weaning from mechanical ventilation. Am Rev Respir Dis 1987;135(6):1320–1328.
    OpenUrlPubMed
  6. 6.↵
    1. Jubran A,
    2. Tobin MJ
    . Pathophysiological basis of acute respiratorv distress in patients who fail a trial of weaning from mechanical ventilation. Am J Respir Crit Care Med 1997;155(3):906–915.
    OpenUrlPubMed
  7. 7.↵
    1. Frutos-Vivar F,
    2. Esteban A,
    3. Apezteguia C,
    4. Gonzalez M,
    5. Arabi Y,
    6. Restrepo MI,
    7. et al
    . Outcome of reintubated patients after scheduled extubation. J Crit Care 2011;26(5):502–509.
    OpenUrlPubMed
  8. 8.↵
    1. Epstein SK,
    2. Ciubotaru RL,
    3. Wong JB
    . Effect of failed extubation on the outcome of mechanical ventilation. Chest 1997;112(1):186–192.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Esteban A,
    2. Alía I,
    3. Gordo F,
    4. Fernández R,
    5. Solsona JF,
    6. Vallverdú I,
    7. et al
    . Extubation outcome after spontaneous breathing trials with T-tube or pressure support ventilation: the Spanish Lung Failure Collaborative Group Am J Respir Crit Care Med 1997;156(2 Pt 1):459–465. Erratum in: Am J Respir Crit Care Med 1997;156(6):2028.
    OpenUrlCrossRefPubMed
  10. 10.
    1. Vallverdú I,
    2. Calaf N,
    3. Subirana M,
    4. Net A,
    5. Benito S,
    6. Mancebo J
    . Clinical characteristics, respiratory functional parameters, and outcome of a two-hour T-piece trial in patients weaning from mechanical ventilation. Am J Respir Crit Care Med 1998;158(6):1855–1862.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Ely EW,
    2. Baker AM,
    3. Evans GW,
    4. Haponik EF
    . The prognostic significance of passing a daily screen of breathing spontaneously. N Engl J Med 1999;25(6):581–587.
    OpenUrl
  12. 12.
    1. Epstein SK,
    2. Ciubotaru RL
    . Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation. Am J Respir Crit Care Med 1998;158(2):489–493.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Esteban A,
    2. Frutos F,
    3. Tobin MJ,
    4. Alía I,
    5. Solsona JF,
    6. Vallverdú I,
    7. et al
    . A comparison of four methods of weaning patients from mechanical ventilation: the Spanish Lung Failure Collaborative Group. N Engl J Med 1995;332(6):345–350.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Brochard L,
    2. Rauss A,
    3. Benito S,
    4. Conti G,
    5. Mancebo J,
    6. Rekik N,
    7. et al
    . Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation. Am J Respir Crit Care Med 1994;150(4):896–903.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Dojat M,
    2. Harf A,
    3. Touchard D,
    4. Laforest M,
    5. Lemaire F,
    6. Brochard L
    . Evaluation of a knowledge-based system providing ventilatory management and decision for extubation. Am J Respir Crit Care Med 1996;153(3):997–1004.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Hess DR,
    2. MacIntyre NR
    . Ventilator discontinuation: why are we still weaning? Am J Respir Crit Care Med 2011;184(4):392–394.
    OpenUrlCrossRefPubMed
  17. 17.↵
    1. MacIntyre NR,
    2. Epstein SK,
    3. Carson SS,
    4. Scheinhorn D,
    5. Christopher K,
    6. Muldoon S
    ; National Association for Medical Direction of Respiratory Care. Management of patients requiring prolonged mechanical ventilation: report of a NAMDRC Consensus Conference. Chest 2005;128(6):3937–3954.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. White AC
    . Long term mechanical ventilation: management strategies. Respir Care 2012;57(6):889–899.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. Yang KL
    . Reproducibility of weaning parameters: a need for standardization. Chest 1992;102(6):1829–1832.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Cook D,
    2. Meade M,
    3. Guyatt G,
    4. Griffith L,
    5. Booker L
    . Evidence report on criteria for weaning from mechanical ventilation. Rockville, MD: Agency for Health Care Policy and Research; June 2000. http://www.ncbi.nlm.nih.gov/books/NBK33323. Accessed July 17, 2012.
  21. 21.↵
    1. Tejerina E,
    2. Esteban A,
    3. Fernández-Segoviano P,
    4. María Rodríguez-Barbero J,
    5. Gordo F,
    6. Frutos-Vivar F,
    7. et al
    . Clinical diagnoses and autopsy findings: discrepancies in critically ill patients. Crit Care Med 2012;40(3):842–846.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Kollef MH,
    2. Shapiro SD,
    3. Silver P,
    4. St John RE,
    5. Prentice D,
    6. Sauer S,
    7. et al
    . A randomized, controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilation. Crit Care Med 1997;25(4):567–574.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Esteban A,
    2. Alía I,
    3. Tobin MJ,
    4. Gil A,
    5. Gordo F,
    6. Vallverdú I,
    7. et al
    . Effect of spontaneous breathing trial duration on outcome of attempts to discontinue mechanical ventilation: the Spanish Lung Failure Collaborative Group. Am J Respir Crit Care Med 1999;159(2):512–518.
    OpenUrlCrossRefPubMed
  24. 24.↵
    1. deHaven CB,
    2. Kirton OC,
    3. Morgan JP,
    4. et al
    . Breathing measurements reduces false negative classification of tachypneic pre-extubation trial failures. Crit Care Med 1996;24(6):976–980.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Tanios MA,
    2. Nevins MI,
    3. Hendra KP,
    4. Hart AM Shatz DV,
    5. Civetta JM
    . A randomized controlled trial of the role of weaning predictors in clinical decision making. Crit Care Med 2006;34(6):2530–2535.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Yang KL,
    2. Tobin MJ
    . A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation. N Engl J Med 1991;324(21):1445–1450.
    OpenUrlCrossRefPubMed
  27. 27.↵
    1. Cohen C,
    2. Zagelbaum G,
    3. Gross D,
    4. Roussos C,
    5. Macklem PT
    . Clinical manifestations of inspiratory muscle fatigue. Am J Med 1982;73(3):308–316.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Feeley TW,
    2. Saumarez R,
    3. Klick JM,
    4. McNabb TG,
    5. Skillman JJ
    . Positive end-expiratory pressure in weaning patients from controlled ventilation: a prospective randomized trial. Lancet 1975;2(7938):725–729.
    OpenUrlCrossRefPubMed
  29. 29.
    1. Jones DP,
    2. Byrne P,
    3. Morgan C,
    4. Fraser I,
    5. Hyland R
    . Positive end-expiratory pressure vs T-piece: extubation after mechanical ventilation. Chest 1991;100(6):1655–1659.
    OpenUrlCrossRefPubMed
  30. 30.
    1. Bailey CR,
    2. Jones RM,
    3. Kelleher AA
    . The role of continuous positive airway pressure during weaning from mechanical ventilation in cardiac surgical patients. Anaesthesia 1995;50(8):677–681.
    OpenUrlPubMed
  31. 31.
    1. Petrof BJ,
    2. Legaré M,
    3. Goldberg P,
    4. Milic-Emili J,
    5. Gottfried SB
    . Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in severe chronic obstructive pulmonary disease. Am Rev Respir Dis 1990;141(2):281–289.
    OpenUrlPubMed
  32. 32.↵
    1. Tobin MJ
    . Extubation and the myth of “minimal ventilator settings”. Am J Respir Crit Care Med 2012;185(4):349–50.
    OpenUrlCrossRefPubMed
  33. 33.↵
    1. Jubran A,
    2. Tobin MJ
    . Passive mechanics of lung and chest wall in patients who failed or succeeded in trials of weaning. Am J Respir Crit Care Med 1997;155(3):916–921.
    OpenUrlPubMed
  34. 34.
    1. Tobin MJ,
    2. Laghi F,
    3. Brochard L
    . Role of the respiratory muscles in acute respiratory failure of COPD: lessons from weaning failure. J Appl Physiol 2009;107(3):962–970.
    OpenUrlAbstract/FREE Full Text
  35. 35.
    1. Jubran A,
    2. Parthasarathy S
    . Hypercapneie respiratory failure during weaning: neuromuscular capacity vs muscle loads. Respir Care Clin N Am 2000;6(3):385–406.
    OpenUrlCrossRefPubMed
  36. 36.
    1. Capdevila X,
    2. Perrigault PF,
    3. Ramonatxo M,
    4. Roustan JP,
    5. Peray P,
    6. d'Athis F,
    7. Prefaut C
    . Changes in breathing pattern and respiratory muscle performance parameters during difficult weaning. Crit Care Med 1998;26(1):79–87.
    OpenUrlCrossRefPubMed
  37. 37.↵
    1. Laghi F,
    2. D'Alfonso N,
    3. Tobin MJ
    . Pattern of recovery from diaphragmatic fatigue over 24 hours. J Appl Physiol 1995;79(2):539–546.
    OpenUrlAbstract/FREE Full Text
  38. 38.↵
    1. Lellouche F,
    2. Mancebo J,
    3. Jolliet P,
    4. Roeseler J,
    5. Schortgen F,
    6. Dojat M,
    7. et al
    . A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med 2006;174(8):894–900.
    OpenUrlCrossRefPubMed
  39. 39.↵
    1. Rose L,
    2. Preseneill JJ,
    3. Johnston L,
    4. Cade JF
    . A randomized, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med 2008;34(10):1788–1795.
    OpenUrlCrossRefPubMed
  40. 40.↵
    1. Girard TD,
    2. Kress JP,
    3. Fuchs BD,
    4. Thomason JW,
    5. Schweickert WD,
    6. Pun BT,
    7. et al
    . Efficacy and safety of a paired sedation and ventilator weaning protocol for mechanically ventilated patient in intensive care (Awakening and Breathing Controlled Trial): a randomized controlled trial. Lancet 2008;371(9607):126–134.
    OpenUrlCrossRefPubMed
  41. 41.↵
    1. Hess DR
    . The role of noninvasive ventilation in the ventilator discontinuation process. Respir Care 2012;57(10):1619–1625.
    OpenUrlAbstract/FREE Full Text
  42. 42.↵
    1. Fisher MM,
    2. Raper RF
    . The “cuff leak” test for extubation. Anaesthesia 1992;47(1):10–12.
    OpenUrlPubMed
  43. 43.↵
    1. Miller RL,
    2. Cole RP
    . Association between reduced cuff leak volume and postextubation stridor. Chest 1996;110(4):1035–1040.
    OpenUrlCrossRefPubMed
  44. 44.↵
    1. Engoren M
    . Evaluation of the cuff leak test in cardiac surgery patients. Chest 1999;116(4):1029–1031.
    OpenUrlCrossRefPubMed
  45. 45.↵
    1. Hilberman M,
    2. Kamm B,
    3. Lamy M,
    4. et al
    . An analysis of potential physiological predictors of respiratory adequacy following cardiac surgery. Thorac Cardiovasc Surg 1976;71:711–720.
    OpenUrl
  46. 46.↵
    1. Bach JR,
    2. Saporto LR
    . Criteria for extubation and tracheostomy tube removal for patients with ventilatory failure. Chest 1996;110(6):1566–1571.
    OpenUrlCrossRefPubMed
  47. 47.↵
    1. Chan LY,
    2. Jones AY,
    3. Chung RC,
    4. Hung KN
    . Peak flow rate during induced cough: a predictor of successful decannulation of a tracheotomy tube in neurosurgical patients. Amer J Crit Care 2010;19(3):278–284.
    OpenUrl
  48. 48.↵
    1. Su WL,
    2. Chen YH,
    3. Chen CW,
    4. Yang SH,
    5. Su CL,
    6. Perng WC,
    7. et al
    . Involuntary cough strength and extubation outcomes for patients in an ICU. Chest 2010;137(4):777–782.
    OpenUrlCrossRefPubMed
  49. 49.↵
    1. King CS,
    2. Moores LK,
    3. Epstein SK
    . Should patients be able to follow commands prior to extubation? Respir Care 2010;55(1):56–65.
    OpenUrlAbstract/FREE Full Text
  50. 50.↵
    1. Esteban A,
    2. Anzueto A,
    3. Frutos F,
    4. Alía I,
    5. Brochard L,
    6. Stewart TE,
    7. et al
    ; Mechanical Ventilation International Study Group. Characteristics and outcomes in adult patients receiving mechanical ventilation: a 28-day international study. JAMA 2002;287(3):345–355.
    OpenUrlCrossRefPubMed
  51. 51.↵
    1. Esteban A,
    2. Ferguson ND,
    3. Meade MO,
    4. Frutos-Vivar F,
    5. Apezteguía C,
    6. Brochard L,
    7. et al
    . Evolution of mechanical ventilation in response to clinical research. Am J Respir Crit Care Med 2008;177(2):170–177.
    OpenUrlCrossRefPubMed
  52. 52.↵
    1. Boles JM,
    2. Bion J,
    3. Connors A,
    4. eHerridge M,
    5. Marsh B,
    6. Melot C,
    7. et al
    . Weaning from mechanical ventilation. Eur Respir J 2007;29(5):1033–1056.
    OpenUrlAbstract/FREE Full Text
  53. 53.↵
    1. Peñuelas O,
    2. Frutos-Vivar F,
    3. Fernández C,
    4. Anzueto A,
    5. Epstein SK,
    6. Apezteguía C,
    7. et al
    . Characteristics and outcomes of ventilated patients according to time to liberation from mechanical ventilation. Am J Respir Crit Care Med 2011;184(4):430–437.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Respiratory Care: 57 (10)
Respiratory Care
Vol. 57, Issue 10
1 Oct 2012
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
  • Monthly Podcasts

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evidence-Based Assessments in the Ventilator Discontinuation Process
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Evidence-Based Assessments in the Ventilator Discontinuation Process
Neil R MacIntyre
Respiratory Care Oct 2012, 57 (10) 1611-1618; DOI: 10.4187/respcare.02055

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Evidence-Based Assessments in the Ventilator Discontinuation Process
Neil R MacIntyre
Respiratory Care Oct 2012, 57 (10) 1611-1618; DOI: 10.4187/respcare.02055
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Analyzing the Evidence Base for the Ventilator Discontinuation Process in the ICU
    • Developing Evidence-Based Guidelines: 2001–2002
    • The Evidence-Based Formal Discontinuation Assessment Guidelines
    • Assessing the Need for an Artificial Airway
    • How Has the Evolving Evidence Base Impacted Clinical Practice and Outcomes?
    • Summary
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • mechanical ventilation
  • discontinuation
  • iatrogenic
  • lung injury
  • sedation
  • mortality
  • ventilator dependence
  • spontaneous breathing trial
  • SBT
  • ventilator discontinuation
  • weaning

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board
  • Reprints/Permissions

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire