Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
EditorialEditorials

The Cuff Leak Test: Does It “Leak” Any Information?

Maged Y Argalious
Respiratory Care December 2012, 57 (12) 2136-2137; DOI: https://doi.org/10.4187/respcare.02193
Maged Y Argalious
Postanesthesia Care Unit Anesthesiology Institute The Cleveland Clinic Lerner College of Medicine Cleveland, Ohio
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Post-extubation stridor and upper-airway obstruction are multifactorial in etiology and can occur as a result of laryngotracheal edema, intubation trauma, excessive cuff pressure with mucosal ulceration, and prolonged intubation with secondary inflammation and granuloma formation.1 Cuff leak tests (CLTs) were introduced in an attempt to predict post-extubation upper-airway obstruction and reduce the incidence of extubation failure. Qualitative CLTs were performed by deflating the endotracheal tube (ETT) cuff, blocking the ETT opening, and listening for an audible leak around the ETT while patients were spontaneously breathing.2 In an effort to increase the accuracy of CLTs in detecting post-extubation stridor, methods of quantifying a cuff leak were introduced.

Miller and Cole3 described the cuff-leak test with the ventilator set in assist-control mode at a tidal volume (VT) of 10–12 mL/kg. An inspiratory VT and 6 subsequent expiratory VT values were recorded after oropharyngeal suctioning and ETT cuff deflation. The cuff leak was measured as the difference between the preset inspiratory VT and the average of the 3 lowest of the subsequent 6 expiratory VT values. The threshold cuff-leak volume was determined by visual inspection of the receiver-operating characteristic plot. A leak of < 110 mL was considered a positive result of the CLT and indicated that patients were at risk for post-extubation stridor secondary to laryngeal edema.3

This quantitative cuff leak has been expressed as an absolute volume or as a percentage of the inspired VT. When the cuff leak volume is < 110–130 mL3,4 or < 10–15.5%5,6 of the delivered VT, the risk for post-extubation stridor is significantly elevated. Other attempts have focused on quantifying a cuff leak volume in spontaneously breathing patients receiving CPAP.7 The leak volume was calculated as the difference between the expiratory VT with inflated cuff and the expiratory VT with deflated cuff.

Even with quantifiable cuff leak volumes, studies reported a low sensitivity and a low positive predictive value of cuff leak volumes in detecting post-extubation stridor.3–5,8 This was attributed to several factors, including the lack of standardization of the ratio of ETT size to the laryngeal diameter (a large ETT will result in a smaller cuff leak volume for the same laryngeal diameter), and the possible contribution of the exhaled limb of the breathing circuit and the ventilator to an increased airway resistance and therefore an increase in cuff leak volume.

In an effort to eliminate the ETT size as a confounding variable, Gros et al, in this issue of Respiratory Care, evaluated the use of intra-individual variation of the cuff-leak test (ΔCLT), as a predictor of post-extubation stridor.9 They performed the CLT (as proposed by Miller and Cole) immediately after intubation (T0) and before extubation (T1) to evaluate the differences in cuff leak: ΔCLT = CLT1 – CLT0. A positive CLT was defined as ΔCLT < 0 mL, according to the receiver-operating characteristic curve.

Unfortunately, this did not improve the accuracy of the standard pre-extubation cuff-leak test in predicting post-extubation stridor. As the authors state in their discussion, other confounding variables have been introduced by measuring ΔCLT, including the change in pulmonary compliance between the T0 and T1 measurements and the different conditions under which T0 and T1 were conducted, with patients sedated and paralyzed during T0 while awake and actively participating during T1.

So how do we interpret the findings of this and other studies on cuff leak test? Most studies on cuff leak volume document a high specificity and a high negative predictive value (Table), which means that patients with a cuff leak volume above a certain threshold (ΔCLT above 0 mL, cuff leak volume > 15% of VT or > 140 mL) have a low probability of developing post-extubation stridor. Incorporating the CLT into the clinical decision making tree may avoid unnecessary delays in extubating patients for fear of post-extubation stridor, once other extubation criteria are met.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table.

Definitions of Cuff Leak Test Sensitivity, Specificity, and Predictive Values

Since CLT has a low sensitivity and a low positive predictive value, patients with a positive CLT may or may not develop post-extubation stridor. Even though Gros et al9 reported a sensitivity of 86% in their study results, the wide confidence intervals (95% CI 42–100%), and the results of other studies point to an overall low sensitivity of cuff leak volumes in detecting post-extubation stridor. While there is currently no evidence that delaying extubation of patients with a positive CLT improves outcomes, the following considerations can help to reduce the incidence of extubation failure and improve the success rate of reintubation attempts

  • Careful evaluation of other extubation parameters, especially that laryngeal pathology is one of many causes of extubation failure. The incidence of reintubation within 48–72 hours of ETT removal is in the range of 12.5% in the critical care population.1

  • Fiberoptic evaluation of the airway to confirm or exclude laryngeal edema, especially in patients with recent large fluid shifts, prone positioning with dependent facial edema, and external facial swelling.

  • A preformulated plan for securing the airway in case reintubation becomes necessary. This includes the availability of clinicians with airway management expertise, and immediate access to various intubation and ventilation equipment (fiberoptic equipment, laryngeal mask airways, emergency cricothyroidotomy)

  • Use of steroids to reduce laryngeal edema10

  • Use of airway exchange catheters, which can provide temporary oxygenation until definitive measures to secure the airway are taken, in case of extubation failure, and can also act as a conduit for reintubation11

Gros et al are to be congratulated for their attempts to improve the accuracy of the CLT in detecting post-extubation stridor by using patients as their own controls. The elimination of one confounding variable in their study (relationship of tube size to laryngeal diameter) was shadowed by the introduction of 2 other confounders: the change in pulmonary compliance, and the different conditions under which the CLT was performed (sedated/paralyzed vs awake). The incidence of post-extubation stridor in their study (6.7%) is in line with the results of most trials in the medical and surgical population, and is a reminder that being prepared for management of post-extubation stridor (and other causes of extubation failure) may be more important than trying to predict its occurrence.

Footnotes

  • Correspondence: Maged Y Argalious MD MBA, Postanesthesia Care Unit, Anesthesiology Institute, The Cleveland Clinic, 9500 Euclid Avenue, G-3, Cleveland OH 44195. E-mail: argalim{at}ccf.org.
  • The author has disclosed no conflicts of interest.

  • See the Original Study on Page 2026

  • Copyright © 2012 by Daedalus Enterprises Inc.

References

  1. 1.↵
    1. Epstein SK
    . Preventing postextubation respiratory failure. Crit Care Med 2006;34(5):1547–1548.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Potgieter PD,
    2. Hammond JM
    . “Cuff” test for safe extubation following laryngeal edema. Crit Care Med 1988;16(8):818.
    OpenUrlPubMed
  3. 3.↵
    1. Miller RL,
    2. Cole RP
    . Association between reduced cuff leak volume and postextubation stridor. Chest 1996;110(4):1035–1040.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Jaber S,
    2. Chanques G,
    3. Matecki S,
    4. Ramonatxo M,
    5. Vergne C,
    6. Souche B,
    7. et al
    . Postextubation stridor in intensive care unit patients. Risk factors evaluation and importance of the cuff-leak test. Intensive Care Med 2003;29(1):69–74.
    OpenUrlPubMed
  5. 5.↵
    1. De Bast Y,
    2. De Backer D,
    3. Moraine JJ,
    4. Lemaire M,
    5. Vandenborght C,
    6. Vincent JL
    . The cuff leak test to predict failure of tracheal extubation for laryngeal edema. Intensive Care Med 2002;28(9):1267–1272.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Sandhu RS,
    2. Pasquale MD,
    3. Miller K,
    4. Wasser TE
    . Measurement of endotracheal tube cuff leak to predict postextubation stridor and need for reintubation. J Am Coll Surg 2000;190(6):682–687.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Antonaglia V,
    2. Vergolini A,
    3. Pascotto S,
    4. Bonini P,
    5. Renco M,
    6. Peratoner A,
    7. et al
    . Cuff-leak test predicts the severity of postextubation acute laryngeal lesions: a preliminary study. Eur J Anaesthesiol 2010;27(6):534–541.
    OpenUrlPubMed
  8. 8.↵
    1. Engoren M
    . Evaluation of the cuff-leak test in a cardiac surgery population. Chest 1999;116(4):1029–31.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Gros A,
    2. Holzapfel L,
    3. Marqué S,
    4. Perard L,
    5. Demingeon G,
    6. Piralla B,
    7. et al
    . Intra-individual variation of the cuff-leak test as a predictor of post-extubation stridor. Respir Care 2012;57(12):2026–2031.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Cheng K,
    2. Hou C,
    3. Huang H,
    4. Lin S,
    5. Zhang H
    . Intravenous injection of methylprednisolone reduces the incidence of postextubation stridor in intensive care unit patients. Crit Care Med 2006;34(5):1345–1350.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Argalious M
    . Management of PACU emergencies. ASA Refresher Course Anesthesiology 2009;7(1):1–12.
    OpenUrl
PreviousNext
Back to top

In this issue

Respiratory Care: 57 (12)
Respiratory Care
Vol. 57, Issue 12
1 Dec 2012
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
  • Monthly Podcasts

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Cuff Leak Test: Does It “Leak” Any Information?
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
The Cuff Leak Test: Does It “Leak” Any Information?
Maged Y Argalious
Respiratory Care Dec 2012, 57 (12) 2136-2137; DOI: 10.4187/respcare.02193

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
The Cuff Leak Test: Does It “Leak” Any Information?
Maged Y Argalious
Respiratory Care Dec 2012, 57 (12) 2136-2137; DOI: 10.4187/respcare.02193
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire