Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
LetterLetter

Errors in Turbuhaler Technique in a Spanish Population of Asthmatic Patients

Victoria García-Cárdenas, Daniel Sabater-Hernández, José P García-Corpas, María J Faus, Fernando Martínez-Martínez and Shalom I Benrimoj
Respiratory Care May 2012, 57 (5) 817-818; DOI: https://doi.org/10.4187/respcare.01757
Victoria García-Cárdenas
Pharmaceutical Care Research Group Faculty of Pharmacy University of Granada Granada, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Daniel Sabater-Hernández
Pharmaceutical Care Research Group Faculty of Pharmacy University of Granada Granada, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
José P García-Corpas
Pharmaceutical Care Research Group Faculty of Pharmacy University of Granada Granada, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
María J Faus
Pharmaceutical Care Research Group Faculty of Pharmacy University of Granada Granada, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fernando Martínez-Martínez
Pharmaceutical Care Research Group Faculty of Pharmacy University of Granada Granada, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shalom I Benrimoj
Graduate School of Health University of Technology Sydney Sydney, New South Wales, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Appropriate use of inhalers requires a number of steps to be performed correctly to ensure adequate medication delivery and to minimize side effects. Currently, with the advancements in asthma treatment, there is a wide variety of new inhaler devices, which are intended to improve drug administration. However, a recent literature review has shown that misuse of inhaler devices is frequent in practice,1 leading to poor asthma control.2–4 Basheti et al5 have recently described the most frequent inhaler technique errors for patients treated with Turbuhaler and Diskus devices in Jordan and Australia.

Studies aimed at identifying frequent errors regarding inhaler technique are essential, since health strategies can be designed in order to educate asthmatic patients, reinforcing the most common problems related to each inhaler device. Pharmacists are ideally positioned to teach inhaler technique, as they are highly accessible health professionals who see asthmatic patients regularly. In Spain, asthma guidelines recommend that pharmacists should form part of a team approach to patient education about the use of inhalers.6

According to national and international asthma guideline recommendations, the AFasma project integrated 51 community pharmacies in the Spanish provinces of Madrid and Málaga into multidisciplinary teams supporting patients with asthma. As part of this study aiming to investigate the effect of an educational intervention on the control of asthma, we collected information about errors in the Turbuhaler technique performed by 362 asthmatic patients treated with budesonide/formoterol (Symbicort Turbuhaler, AstraZeneca). To our knowledge, this is the first approach in Spain to the most frequent inhaler errors for Turbuhaler users. Inhaler technique was assessed according to guidelines in the Spanish Guide for Asthma Management,6 using a 10 step Turbuhaler checklist. Interestingly, this checklist integrated additional steps (Table 1: steps 8, 9, and 10) not considered by other authors, which are also included in the package leaflet of the product as important steps that should be performed for proper inhaler use. A descriptive analysis of the errors observed is shown in Table 1.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1.

Proportion of Patients With Incorrect Performance of Steps for Turbuhaler Inhaler Technique (n = 367)

In our study, 21.3% of patients performed the 10 Turbuhaler steps correctly, 47% of the patients failed to “breathe out gently, not breathing into the Turbuhaler” (step 4), and 42.5% failed to “remove inhaler from mouth, hold breath for 8 seconds, and exhale away from the mouthpiece” (step 7). Despite using a different inhaler technique assessment tool, these results are similar to those described by Basheti et al,5 who found that a high proportion of Turbuhaler users failed to exhale to residual volume, to exhale away from the mouthpiece, and to hold the breath for 5 seconds.

A relevant finding of our study is that neither the 51.6% of patients prescribed a double dose performed step 8 (if further doses are needed, wait 30 seconds and repeat steps from 2 to 7), nor did 42.8% perform step 10 (rinse mouth with water, do not swallow). As previously commented, these steps were not assessed by other authors. In our opinion, they should be considered when giving a complete inhaler technique education. First, patients treated with inhaled corticosteroids risk having local side effects when not rinsing the mouth with water. Second, waiting 30 seconds between consecutive doses (step 8), which was performed by more than one third of our cohort (34.8%), allows patients to administer a deeper second inhalation, which could improve the effectiveness of the asthma medication.

In conclusion, we have identified an opportunity to reinforce and complete educational interventions for asthmatic patients. Moreover, given the high proportion of patients who failed to perform steps 8 and 10, and the clinical relevance related to effectiveness and safety of asthma treatment, they should be integrated in every inhaler technique assessment tool and taken into account when designing educational programs to improve asthma control.

Footnotes

  • The authors have disclosed a relationship with AstraZeneca.

  • Copyright © 2012 by Daedalus Enterprises Inc.

References

  1. 1.↵
    1. Lavorini F,
    2. Magnan A,
    3. Dubus JC,
    4. Voshaar T,
    5. Corbetta L,
    6. Broeders M,
    7. et al
    . Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir Med 2008;102(4):593–604.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Armour CL,
    2. Lemay K,
    3. Saini B,
    4. Reddel HK,
    5. Bosnic-Anticevich SZ,
    6. Smith LD,
    7. et al
    . Using the community pharmacy to identify patients at risk of poor asthma control and factors which contribute to this poor control. J Asthma 2011;48(9):914–922.
    OpenUrlPubMed
  3. 3.↵
    1. Melani AS,
    2. Bonavia M,
    3. Cilenti V,
    4. Cinti C,
    5. Lodi M,
    6. Martucci P,
    7. et al
    . Inhaler mishandling remains common in real life and is associated with reduced disease control. Respir Med 2011;105(6):930–938.
    OpenUrlPubMed
  4. 4.↵
    1. Molimard M,
    2. Le Gros V
    . Impact of patient-related factors on asthma control. J Asthma 2008;45(2):109–113.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Basheti IA,
    2. Qunaibi E,
    3. Bosnic-Anticevich SZ,
    4. Armour CL,
    5. Khater S,
    6. Omar M,
    7. et al
    . User error with Diskus and Turbuhaler by asthma patients and pharmacists in Jordan and Australia. Respir Care 2011;56(12):1916–1923.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    GEMA Educadores. Manual del educador en asma. 2010. Guide in Spanish. http://www.gemasma.com/images/stories/GEMASMA/Documentos/GEMA%20Educadores/index.html. Accessed February 29, 2012.

The authors respond:

818 819

We thank García-Cárdenas et al for their comments on our paper, and for providing data that show high rates of incorrect inhaler technique among a large group of patients in Spain. These findings add to our data about incorrect inhaler technique by patients and pharmacists in Jordan and Australia.1

Heterogeneity among inhaler checklists is a problem when comparing results of studies conducted in different populations. In our study we used 9 step checklists for Turbuhaler and Diskus inhaler technique assessment. García-Cárdenas et al recommend checking an additional 3 steps when assessing Turbuhaler technique:

  • If further doses are needed, wait 30 seconds and repeat steps from 2 to 7.

  • Replace the device cap.

  • Rinse the mouth with water and do not swallow

Although not reported in our paper, these steps were asked or observed for the patients in the Jordanian arm of our study (n = 40). Turbuhaler users who were prescribed 2 doses (25%) were asked what they knew about using 2 consecutive doses; the results were similar to those from García-Cárdenas et al, with only 20% (no. = 10) saying that they waited between the doses. After the technique assessment, patients using inhaled corticosteroids were asked, “What do you do following your dose administration?” and only 30% (no. = 12) reported that they rinsed their mouth. However, all patients were observed to replace the cap on their Turbuhaler after they finished their inhaler technique assessment.

Although these steps may be of importance in clinical practice, we do not believe that they should necessarily all be included in the actual assessment checklist. One perspective is that a device specific assessment checklist should reflect the principle established by Appel et al,2 that the better the inhaler technique (the more correct steps performed) by the patient, the higher the clinical response expected.3,4 In addition, individual steps included in a standardized checklist need to be relevant to all patients using the device, so that the maximum potential score is the same on each occasion and scores can be compared between patients, visits, and studies.

The instruction to wait for 30 seconds between doses does not appear on the manufacturer's leaflets in countries such as Jordan, Canada, Australia, and the United States, and there does not appear to be any published evidence to support a 30 second delay. This step would also be relevant only to patients prescribed 2 or more inhalations from their Turbuhaler, limiting the extent to which inhaler technique scores could be compared.

We agree with García-Cárdenas et al that replacing the Turbuhaler cap after use is important to avoid absorption of moisture by the drug, which would impact drug delivery.5 This step is included in the manufacturer's instructions, but in fewer than half of published Turbuhaler checklists. This may be an oversight, or because the potential impact of drug aggregation on clinical effectiveness would be gradual, and would depend on factors such as ambient humidity.

The third extra step is rinsing the mouth after use of the Turbuhaler. We agree that this is important in clinical practice for patients using inhaled corticosteroids, to reduce the risk of side effects. However, it should not be an obligatory component of a Turbuhaler technique checklist, because Turbuhalers are also used for delivery of short- or long-acting β2 agonists, for which mouth rinsing is not required.

Nevertheless, we agree with García-Cárdenas et al that these steps should be considered while delivering a complete Turbuhaler technique education. Patients for whom a second dose or mouth rinsing is relevant may need to be asked about these steps during their visits, as they may not necessarily think to perform these steps when asked, outside their home setting, to demonstrate how they use their inhaler.

The divergence between inhaler technique checklists used for the same device in different studies makes direct comparison of results difficult. This may introduce inaccuracy in the way the results are compared, and cause confusion for patients and health professionals. The issue of inhaler technique checklist heterogeneity is important and has been addressed since more than a decade ago.6 The present discussion supports the fact that further work needs to be done to standardize inhaler technique assessment checklists.

References

  1. 1.
    1. Basheti IA,
    2. Qunaibi E,
    3. Bosnic-Anticevich SZ,
    4. Armour CL,
    5. Khater S,
    6. Omar M,
    7. et al
    . User error with Diskus and Turbuhaler by asthma patients and pharmacists in Jordan and Australia. Respir Care 2011;56(12):1916-1923.
    OpenUrlAbstract/FREE Full Text
  2. 2.
    1. Appel D
    . Faulty use of canister nebulizers for asthma. Pharmacy Practice 1982;14(6):1135-1139.
    OpenUrl
  3. 3.
    1. Basheti IA,
    2. Armour CL,
    3. Bosnic-Anticevich SZ,
    4. Reddel HK
    . Evaluation of a novel educational strategy, including inhaler-based reminder labels, to improve asthma inhaler technique. Patient Educ Couns 2008;72(1):26-33.
    OpenUrlCrossRefPubMed
  4. 4.
    1. Basheti IA,
    2. Reddel HK,
    3. Armour CL,
    4. Bosnic-Anticevich SZ
    . Improved asthma outcomes with a simple inhaler technique intervention by community pharmacists. J Allergy Clin Immunol 2007;119(6):1537-1538.
    OpenUrlCrossRefPubMed
  5. 5.
    1. Borgstrom L,
    2. Asking L,
    3. Lipniunas P
    . An in vivo and in vitro comparison of two powder inhalers following storage at hot/humid conditions. J Aerosol Med 2005;18(3):304-310.
    OpenUrlPubMed
  6. 6.
    1. Brocklebank D,
    2. Ram F,
    3. Wright J,
    4. Barry P,
    5. Cates C,
    6. Davies L,
    7. et al
    . Comparison of the effectiveness of inhaler devices in asthma and chronic obstructive airways disease: a systematic review of the literature. Health Technol Assess 2001;5(26):1-149.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

Respiratory Care: 57 (5)
Respiratory Care
Vol. 57, Issue 5
1 May 2012
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Errors in Turbuhaler Technique in a Spanish Population of Asthmatic Patients
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Errors in Turbuhaler Technique in a Spanish Population of Asthmatic Patients
Victoria García-Cárdenas, Daniel Sabater-Hernández, José P García-Corpas, María J Faus, Fernando Martínez-Martínez, Shalom I Benrimoj
Respiratory Care May 2012, 57 (5) 817-818; DOI: 10.4187/respcare.01757

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Errors in Turbuhaler Technique in a Spanish Population of Asthmatic Patients
Victoria García-Cárdenas, Daniel Sabater-Hernández, José P García-Corpas, María J Faus, Fernando Martínez-Martínez, Shalom I Benrimoj
Respiratory Care May 2012, 57 (5) 817-818; DOI: 10.4187/respcare.01757
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Footnotes
    • References
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire