Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Coming Next Month
    • Archives
    • Most-Read Papers of 2021
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2022 Open Forum
    • 2021 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Coming Next Month
    • Archives
    • Most-Read Papers of 2021
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2022 Open Forum
    • 2021 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleOriginal Research

Neonatal and Pediatric Manual Hyperinflation: Influence of Oxygen Flow on Ventilation Parameters

Pricila Mara Novais de Oliveira, Armando Augusto Almeida-Junior, Celize Cruz Bresciani Almeida, Maria Ângela Gonçalves de Oliveira Ribeiro and José Dirceu Ribeiro
Respiratory Care December 2013, 58 (12) 2127-2133; DOI: https://doi.org/10.4187/respcare.02336
Pricila Mara Novais de Oliveira
Department of Pediatrics, Faculty of Medical Sciences
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Armando Augusto Almeida-Junior
Hospital de Clínicas, Universidade Estadual de Campinas, Campinas, São Paulo, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Celize Cruz Bresciani Almeida
Hospital de Clínicas, Universidade Estadual de Campinas, Campinas, São Paulo, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Maria Ângela Gonçalves de Oliveira Ribeiro
Department of Pediatrics, Faculty of Medical Sciences
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
José Dirceu Ribeiro
Department of Pediatrics, Faculty of Medical Sciences
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

BACKGROUND: Although self-inflating bags are widely used for manual hyperinflation, they do not allow ventilation parameters, such as pressure or volume, to be set. We studied the ventilation performance of neonatal and pediatric self-inflating bags.

METHODS: We asked 22 physiotherapists to manually hyperinflate 2 lung models (neonatal and pediatric), using self-inflating bags from 3 manufactures (Hudson, Laerdal, and JG Moriya), with flows of 0, 5, 10, and 15 L/min. A pneumotachograph recorded tidal volume (VT), peak inspiratory pressure (PIP), peak inspiratory flow (PIF), peak expiratory flow (PEF), and inspiratory time.

RESULTS: The VT, PIP, and inspiratory time delivered by the Hudson, Laerdal, and JG Moriya bags, in both neonatal and pediatric self-inflating bags, were significantly different (P < .001). The PEF and PIF delivered were different only when using the neonatal self-inflating bags (P < .001). The VT, PIP, and PIF delivered with a flow of 0 L/min were lower than with 15 L/min (P < .05) with all the tested bags, in both the neonatal and pediatric sizes.

CONCLUSIONS: The performance of the tested neonatal and pediatric bags varied by manufacturer and oxygen flow. There was an increase in VT, PIP, and PIF related to the increase of oxygen flow from 0 L/min to 15 L/min. The neonatal bags showed higher ventilation parameters variation than the pediatric bags.

  • resuscitation
  • manual hyperinflation
  • self-inflating bag
  • pediatric
  • respiratory therapy
  • respiratory function monitor

Introduction

Manual hyperinflation is used to improve secretion clearance and alveolar expansion in mechanically ventilated patients, and the self-inflating bag is the main device used in manual hyperinflation, but the self-inflating bag does not allow ventilation parameters, such as pressure, volume, or FIO2, to be set.1–3

The American Society for Testing and Materials established standards4 for self-inflating bags. However, important physical and functional differences can be observed during cardiopulmonary resuscitation.5–13 These differences are among neonatal devices from different manufacturers. Several studies have confirmed that several factors might interfere with the performance of neonatal pulmonary ventilation.5,14,15 The factors are professional experience and training,12,16,17 lung compliance,18 visual feedback, pressure manometer,19 number of hands used in bag compression,20,21 and the operator's hand size.22 All these factors can affect the ventilation parameters of manual hyperinflation. Such variance may impact clinical outcomes.

Few studies have evaluated the functional performance of neonatal self-inflating bags according to oxygen flows, but they assessed only the FIO2.13,23,24 There have been no studies of the relationship between self-inflating bags' ventilation parameters with different oxygen flows applied. We studied the performance of neonatal and pediatric self-inflating bags from 3 manufacturers, at different oxygen flows, during manual hyperinflation.

QUICK LOOK

Current knowledge

Manual hyperinflation is used to improve secretion clearance and alveolar expansion in mechanically ventilated patients. The self-inflating bag is the primary device used in manual hyperinflation, but bagging does not allow good control of ventilation parameters such as pressure, volume, or FIO2.

What this paper contributes to our knowledge

The performance of neonatal and pediatric bags varied during manual hyperinflation, by manufacturer and by the oxygen flow applied. There was an increase in tidal volume, peak inspiratory pressure, peak inspiratory flow, and inspiratory time related to the oxygen flow, from 0 to 15 L/min. The neonatal bags showed greater ventilatory parameter variation than the pediatric bags.

Methods

Design and Ethics

The study had a randomized crossover design, and was approved by the University of Campinas ethics committee (408/2008).

Setting

The study was conducted at the Biomedical Engineering Center of the University of Campinas. We recruited 22 physiotherapists at the Hospital de Clínicas, Universidade Estadual de Campinas, Campinas, São Paulo, Brazil. Eleven of the physiotherapists recruited had clinical experience with bagging critically ill neonates and children, and 11 did not. No prior training was conducted with the subjects. They were instructed to manually hyperinflate with slow inflation and rapid inspiratory pause, followed by fast bag release.

The manual hyperinflation was simulated to set up the respiratory mechanics of a neonate and a pediatric intubated patient in a test lung model (Ventilator Tester 2, Biotek, Winooski, Vermont) (Fig. 1). We used a leak-free and intubated model. Measurements were recorded at different values of pulmonary compliance and resistance, to simulate 2 clinical situations: healthy, normal respiratory mechanics, and restrictive mechanics (decreased pulmonary compliance). The lung resistance was set at 50 cm H2O/L/s to simulate a newborn, and at 20 cm H2O/L/s to simulate a child. The pulmonary compliance was set at 3 m L/cm H2O to simulate normal compliance in a healthy newborn, at 1 m L/cm H2O to simulate reduced lung compliance in a newborn, at 10 m L/cm H2O to simulate normal compliance in a healthy child, and at 3 m L/cm H2O to simulate reduced lung compliance in a child. These compliance and resistance values were based on a previous study.20 The test lung apparatus was calibrated considering the environmental temperature, atmospheric pressure, and relative air humidity before the experiments.

Fig. 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.

Test lung model and ventilator tester.

The subjects used only their dominant hand. They were encouraged to ventilate the test lung as they would ventilate a patient, and to rest between tests to avoid fatigue. They were allowed to familiarize themselves with the equipment and environment. The tests were randomized. No visual or verbal feedback was provided during the tests.

After the tests, the subjects underwent a standardized interview about the bags' performance.

Self-Inflating Bags

Each subject used 6 new self-inflating bag units. The tested bags were obtained from 3 manufacturers: Hudson RCI/Teleflex Medical (Research Triangle Park, North Carolina), Laerdal Medical (Stavanger, Norway), and JG Moriya (São Paulo, Brazil) (Fig. 2). All the bags were tested with both the neonatal and pediatric models. The bags were connected to a 50-psig source of 100% oxygen, and flows of 0, 5, 10, and 15 L/min were delivered. An oxygen reservoir was attached to the unit when the oxygen flow meter was set above 5 L/min. The pressure relief valve was kept unlocked.

Fig. 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.

Neonatal self-inflating bags: Laerdal, Hudson, and JG Moriya.

The volumes of the bags tested were: Hudson neonatal 280 mL, Hudson pediatric 500 mL, Laerdal neonatal 240 mL, Laerdal pediatric 500 mL, JG Moriya neonatal 130 mL, and JG Moriya pediatric 250 mL.

The bias was reduced by not telling the subjects what was being investigated. The order of the bag handling, compliance settings, and experience levels of the subjects were randomly assigned. The oxygen flows were used sequentially: 0, 5, 10, and 15 L/min, but the physiotherapists were unaware of this assignment.

Each physiotherapist performed 10 manual hyperinflations with each of the 6 bags (neonatal bag and pediatric bag from 3 manufacturers), with both normal and reduced compliance, and at all 4 flows.

Pneumotachograph

A sensor CO2 Capnostat (Novametrix, Wallingford, Connecticut) attached to the pneumotachograph (CO2SMO+, Novametrix, Wallingford, Connecticut) was fitted at the interface between the test lung and the bag, with no important increase in dead space. The signals were recorded by software (Analysis Plus, Novametrix, Wallingford, Connecticut). The physiotherapists were blinded to the pneumotachograph display.

The variables measured were tidal volume (VT), peak inspiratory pressure (PIP), peak expiratory flow (PEF), peak inspiratory flow (PIF), and inspiratory time.

Statistical Analysis

Statistical analysis was performed with statistics software (SAS 9.1.3, SAS Institute, Cary, North Carolina). The Kolmogorov-Smirnov test was used to assess data distribution, and the data did not have normal distribution, so all the variables were transformed into ranks. We calculated the mean of 10 inflations per test.

The ventilation measurements were compared for the different bag manufacturers and flows with repeated-measures analysis of variance. Then we applied within-subject contrast tests for post hoc analysis. There was no important period effect because the study was in an experimental setting. The results are reported as median and 95% CI. The significance level for the statistical analysis was P < .05.

Results

VT, PIP, and inspiratory time delivered by the Hudson, Laerdal, and JG Moriya bags, with both the neonatal and pediatric bags, were statistically different (P < .001). PEF and PIF were different only with the neonatal bags. These data were obtained independently of the flow applied (Table 1). Also, Table 1 presents the within-subjects contrasts.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1.

Ventilation Parameters Delivered by Neonatal and Pediatric Self-Inflating Bags*

The PIP delivered ranged from 0 to 46 cm H2O in 528 tests with the neonatal bags. Only one subject provided PIP higher than 40 cm H2O, with the Hudson neonatal bag. With the pediatric bags the PIP ranged from 12 to 52 cm H2O, and 16 of 22 subjects exceeded 40 cm H2O. All these measurements were obtained with the Hudson pediatric bag.

A minimum PIP of 20 cm H2O was not reached in 121 (22.92%) tests with the neonatal bags, and in 116 (21.97%) tests with the pediatric bags. Eighteen physiotherapists failed to deliver PIP greater than 20 cm H2O with the neonatal bags, and 19 with the pediatric bags. The PIP values are presented in Table 2.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 2.

Delivery of Peak Inspiratory Pressures < 20 cm H2O and > 40 cm H2O*

VT, PIP, PIF, and inspiratory time increased with increasing oxygen flow (Fig. 3) and were significantly different at flows of 0 and 15 L/min (P < .001). This result was obtained independently of the bag's manufacturer.

Fig. 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 3.

Tidal volume (VT), peak inspiratory pressure (PIP), and peak inspiratory flow (PIF) from neonatal and pediatric self-inflating resuscitation bags. * P < .05.

The experienced and inexperienced physiotherapists were similar in their overall manual hyperinflation performance; the only difference was the highest PIF in the experienced group (P = .03 for neonatal bags, P = .03 for pediatric bags). The ventilation parameters were different between the normal and reduced compliance settings (P < .001). The subjects delivered a lower VT, a higher PIP, and a higher PIF in the low compliance setting than in the normal compliance setting (all P < .001). The comparison of ventilation parameters delivered by experience level and compliance was previously published.16

Discussion

To our knowledge, this is the first study to measure the influence of oxygen flow on physiotherapist performance with 3 neonatal and pediatric bags. We found functional and physical differences between the 3 tested bag models. These differences have been documented during neonatal resuscitation.1,7,25 In addition, during neonatal and pediatric manual hyperventilation, VT, PIP, and PIF increased with increased oxygen flow. A few studies of neonatal bag performance have found that FIO2 varies with the oxygen flow applied, but those studies did not measure VT, PIP, or PIF.13,23,24

In clinical practice the choice of oxygen flow varies according to the patient's oxygenation. However, the North American Neonatal Resuscitation Program recommends a flow of 5–10 L/min into the bag inlet when it is connected to a 100% oxygen source.26 Often the manufacturers' recommendations are unknown or not respected. The lack of difference in some ventilation parameters between the flows of 5 and 10 L/min demonstrate the safety of using this flow range in daily practice.

The heterogeneous PIPs we found in the present study are in agreement with other studies.9,27 The pressure-relief valve is supposed to open at 35 cm H2O with the Laerdal bag, and at 40 cm H2O with the JG Moriya and Hudson bags we tested; our measured PIPs often exceeded 40 cm H2O with the pediatric bags. This fact is even more important during preterm-infant ventilation, which requires more accurate VT and PIP. Furthermore, it is intriguing to notice how often the PIP cutoff of 20 cm H2O was not reached. This creates a risk of hypoventilation and inadequate alveolar recruitment during manual hyperinflation.

The bags we tested were suitable for each age group; however, the JG Moriya provided lower VT and PIP values than the bags from the other manufacturers. The JG Moriya neonatal bag's PIF was also the lowest among the neonatal bags, so the JG Moriya neonatal bag presumably provides less ventilation. Regardless of international consensus defining the self-inflating bag as the main instrument for manual ventilation, studies have shown that there is no unanimity in the guidelines for self-inflating bag use in neonatal ventilation.6,8,14 Lee et al28 reported that the volumes delivered range widely, and they do not encourage self-inflating bag use for careful and precise ventilation.

The ventilation parameter variation during neonatal manual hyperinflation could be explained by the fact that the neonatal bag (150 mL) is pressurized faster and also distended, when compared to the pediatric bags. This results in the higher pressures and volumes delivered by neonatal bags. Furthermore, an increased plateau pressure due to the low adjusted compliance at the infant setting could reflect in an increased PIP and VT.

There is a wide range of commercial neonatal and pediatric bags manufactured. The differences in the ventilation performance between those bags could be explained mainly by their physical characteristics, including bag and reservoir volume, valve type, valve resistance,29 manufacturing materials, elasticity, density, and bag shape and texture.30 To select the appropriate bag for each clinical setting, the clinician should be familiar with the equipment and check it before use. The choice of an inadequate bag for the patient's weight or the underlying disease could be dangerous.

The majority of our subjects (77%) reported increased resistance squeezing the JG Moriya bag, compared to the Laerdal and Hudson bags. The JG Moriya bag's silicone percentage could explain that higher resistance. Although the devices have similar bag formats, the subjects also described differences in the bags' textures. The Laerdal bag has a shape and texture that provide greater adherence between the bag and the clinician's hand. Mazzolini and Marshall30 indicated that differences in bag design and texture affect the FIO2 delivered by the bag, and that bag shape influences the gripping efficiency and, consequently, the ventilation performance. Bag texture and design can increase the clinician's capacity to perform inflations and prevent the bag from slipping when handled. The bag's manufacturing material can also affect the inflation pressure.18 Therefore, the clinician's ability to sense compliance changes could interfere with the ventilation parameters.

Our results were based on an experimental setting. The subjects could not be blinded to the bag used, and we were not able to test the bag's manufacturing materials. Further studies testing different bag manufacturers and evaluating pressures and volumes could contribute to the current results' application. To determine the optimal gas flow for safe manual hyperinflation will require clinical studies.

The self-inflating bag's use for manual ventilation still presents several advantages over other devices. It does not require a continuous gas flow or a power source to be connected,5 and bag is portable and easy to use.9,31 Based on our results, we recommend that the bag manufacturer and flow applied should be chosen carefully to avoid adverse impacts on clinical outcomes. Although there are several guidelines for resuscitation, recommendations about flow during manual ventilation from the European Respiratory Society or American Thoracic Society were not found.

In agreement with Jones et al,31 the present study suggests that bag selection should match the clinician's experience and skills. It is necessary to learn about a bag's physical and functional characteristics and to check the bag before using it.32 Until manual hyperinflation clinical evidence is available, we suggest that the clinician use a pneumotachograph or at least a manometer to ensure safe ventilation. Bag use by untrained hands can be dangerous.16

Conclusions

The performance of neonatal and pediatric bags varied during manual hyperinflation, by manufacturer and by oxygen flow applied. VT, PIP, PIF, and inspiratory time increased with increased oxygen flow. The neonatal bags had higher ventilation parameter variation than the pediatric bags. Our findings should alert clinicians about differences in manual hyperinflation ventilation parameters, in order to conduct safe manual ventilation.

Footnotes

  • Correspondence: Pricila Mara Novais de Oliveira PT PhD, Laboratório de Fisiologia Pulmonar, Centro de Investigação em Pediatria, Universidade Estadual de Campinas, Cidade Universitária Zeferino Vaz, Campinas, São Paulo, Brazil 13081-970. E-mail: pricila.mno{at}gmail.com.
  • This research was partly supported by Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Brazil.

  • The authors have disclosed no conflicts of interest.

  • Copyright © 2013 by Daedalus Enterprises

References

  1. 1.↵
    1. Finer NN,
    2. Barrington KJ,
    3. Al-Fadley F,
    4. Peters KL
    . Limitations of self-inflating resuscitators. Pediatrics 1986;77(3):417-20.
    OpenUrlAbstract/FREE Full Text
  2. 2.
    1. Goldstein B,
    2. Catlin EA,
    3. Vetere JM,
    4. Arguin LJ
    . The role of in-line manometers in minimizing peak and mean airway pressure during hand regulated ventilation of newborn infants. Respir Care 1989;34(1):23-27.
    OpenUrl
  3. 3.↵
    1. Hudson RCI
    . Lifesaver manual resuscitator-operating manual. Temecula, CA: Hudson RCI; 1993.
  4. 4.↵
    American Society for Testing and Materials (ASTM). Standard specification for minimum performance and safety requirements for resuscitators intended for use with humans. Designation F920-93. Philadelphia: ASTM; Reapproved 1999.
  5. 5.↵
    1. Bennett S,
    2. Finer NN,
    3. Rich W,
    4. Vaucher Y
    . A comparison of three neonatal resuscitation devices. Resuscitation 2005;67(1):113-18.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Dawson JA,
    2. Gerber A,
    3. Kamlin CO,
    4. Davis PG,
    5. Morley CJ
    . Providing PEEP during neonatal resuscitation: which device is best? J Paediatr Child Health 2011;47(10):698-703.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Connors R,
    2. Kissoon N,
    3. Tiffin N,
    4. Frewen TC
    . An evaluation of the physical and functional characteristics of infant resuscitators. Pediatr Emerg Care 1993;9(2):104-107.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Finer NN,
    2. Rich W,
    3. Craft A,
    4. Henderson C
    . Comparison of methods of bag and mask ventilation for neonatal resuscitation. Resuscitation 2001;49(3):299-305.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Hussey SG,
    2. Ryan CA,
    3. Murphy BP
    . Comparison of three manual ventilation devices using an intubated mannequin. Arch Dis Child Fetal Neonatal 2004;89(6):490-493.
    OpenUrl
  10. 10.
    1. Mondolfi AA,
    2. Grenier BM,
    3. Thompson JE,
    4. Bachur RG
    . Comparison of self-inflating bags with anesthesia bags for bag-mask ventilation in the pediatric emergency department. Pediatr Emerg Care 1997;13(5):312-16.
    OpenUrlCrossRefPubMed
  11. 11.
    1. Morley CJ,
    2. Dawson JA,
    3. Stewart MJ,
    4. Hussain F,
    5. Davis PG
    . The effect of a PEEP valve on a Laerdal neonatal self-inflating resuscitation bag. J Paediatr Child Health 2010;46(1-2):51-56.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Roehr CC,
    2. Kelm M,
    3. Fischer HS,
    4. Bührer C,
    5. Schmalisch G,
    6. Proquitté H
    . Manual ventilation devices in neonatal resuscitation: tidal volume and positive pressure-provision. Resuscitation 2010;81(2):202-205.
    OpenUrlPubMed
  13. 13.↵
    1. Thió M,
    2. Bhatia R,
    3. Dawson JA,
    4. Davis PG
    . Oxygen delivery using neonatal self-inflating resuscitation bags without a reservoir. Arch Dis Child Fetal Neonatal 2010;95(5):315-319.
    OpenUrl
  14. 14.↵
    1. Tracy MB,
    2. Klimek J,
    3. Coughtrey H,
    4. Shingde V,
    5. Ponnampalam G,
    6. Hinder M,
    7. et al
    . Mask leak in one-person mask ventilation compared to two-person in newborn infant manikin study. Arch Dis Child Fetal Neonatal 2011;96(3):F195-F200.
    OpenUrlAbstract/FREE Full Text
  15. 15.↵
    1. White JRM,
    2. Shugerman R,
    3. Brownlee C,
    4. Quan L
    . Performance of advanced resuscitation skills by pediatric house staff. Arch Pediatr Adolesc Med 1998;152(12):1232-1235.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Oliveira PMN,
    2. Almeida-Junior AA,
    3. Almeida CC,
    4. Ribeiro MAGO,
    5. Ribeiro JD
    . Does experience influence the performance of neonatal and pediatric manual hyperinflation? Respir Care 2012;57(11):1908-1913.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Resende JG,
    2. Menezes CG,
    3. Paula AM,
    4. Ferreira AC,
    5. Zaconeta CA,
    6. Silva CA,
    7. et al
    . Evaluation of peak inspiratory pressure and respiratory rate during ventilation of an infant lung model with a self-inflating bag. J Pediatr (Rio J) 2006;82(5):359-364.
    OpenUrlPubMed
  18. 18.↵
    1. Kattwinkel J,
    2. Stewart C,
    3. Walsh B,
    4. Gurka M,
    5. Paget-Brown A
    . Responding to compliance changes in a lung model during manual ventilation: perhaps volume, rather than pressure, should be displayed. Pediatrics 2009;123(3):e465-e470.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. O'Donnell CPF,
    2. Davis PG,
    3. Lau R,
    4. Dargaville PA,
    5. Doyle LW,
    6. Morley CJ
    . Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks. Arch Dis Child Fetal Neonatal 2005;90(5):F392-F396.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    1. Bassani MA,
    2. Filho FM,
    3. Coppo MRC,
    4. Marba STM
    . Peak pressure and tidal volume are affected by how the neonatal self-inflating bag is handled. J Pediatr (Rio J) 2009;85(3):217-222. Article in Portuguese.
    OpenUrlPubMed
  21. 21.↵
    1. Ganga-Zandzou PS,
    2. Diependaele JF,
    3. Storme L,
    4. Riou Y,
    5. Klosowski S,
    6. Rakza T,
    7. et al
    . [La ventilation à Ambú chez nouveau-né: une simple question de doigté?] Arch Pediatr 1996;3(12):1270-1272. Article in French.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Hess D,
    2. Spahr C
    . An evaluation of volumes delivered by selected adult disposable resuscitators: the effects of hand size, number of hands used, and use of disposable medical gloves. Respir Care 1990;35(9):800-805.
    OpenUrlPubMed
  23. 23.↵
    1. Johnston KL,
    2. Aziz K
    . The self-inflating resuscitation bag delivers high oxygen concentrations when used without a reservoir: implications for neonatal resuscitation. Respir Care 2009;54(12):1665-1670.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Reise K,
    2. Monkman S,
    3. Kirpalani H
    . The use of the Laerdal infant resuscitator results in the delivery of high oxygen fractions in the absence of a blender. Resuscitation 2009;80(1):120-125.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Field D,
    2. Milner AD,
    3. Hopkin IE
    . Efficiency of manual resuscitators at birth. Arch Dis Child 1986;61(3):300-302.
    OpenUrlAbstract/FREE Full Text
  26. 26.↵
    Health Canada. Family-centered maternity and newborn care: national guidelines. Ottawa: Minister of Public Works and Government Services; 2000:2.19.
  27. 27.↵
    1. Oddie S,
    2. Wyllie J,
    3. Scally A
    . Use of self-inflating bags for neonatal resuscitation. Resuscitation 2005;67(1):109-112.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Lee HM,
    2. Cho KH,
    3. Choi YH,
    4. Yoon SY,
    5. Choi YH
    . Can you deliver accurate tidal volume by manual resuscitator? Emerg Med J 2008;25(10):632-634.
    OpenUrlAbstract/FREE Full Text
  29. 29.↵
    1. Maa SH,
    2. Hung TJ,
    3. Hsu KH,
    4. alZHsieh YI,
    5. Wang KY,
    6. Wang CH,
    7. Lin HC
    . Manual hyperinflation improves alveolar recruitment in difficult-to-wean patients. Chest 2005;128(4):2714-2721.
    OpenUrlCrossRefPubMed
  30. 30.↵
    1. Mazzolini DG Jr.,
    2. Marshall NA
    . Evaluation of 16 adult disposable manual resuscitators. Respir Care 2004;49(12):1509-1514.
    OpenUrlAbstract/FREE Full Text
  31. 31.↵
    1. Jones AYM,
    2. Jones RD,
    3. Bacon-Schone J
    . A comparison of expiratory flow rates in two breathing circuits used for manual hyperinflation of the lungs. Physiotherapy 1991;77:593-597.
    OpenUrl
  32. 32.↵
    1. Hawkes CP,
    2. Ryan CA,
    3. Dempsey EM
    . Comparison of the T-piece resuscitator with other neonatal manual ventilation devices: a qualitative review. Resuscitation 2012;83(7):797-802.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

Respiratory Care: 58 (12)
Respiratory Care
Vol. 58, Issue 12
1 Dec 2013
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
  • Monthly Podcast

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Neonatal and Pediatric Manual Hyperinflation: Influence of Oxygen Flow on Ventilation Parameters
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Neonatal and Pediatric Manual Hyperinflation: Influence of Oxygen Flow on Ventilation Parameters
Pricila Mara Novais de Oliveira, Armando Augusto Almeida-Junior, Celize Cruz Bresciani Almeida, Maria Ângela Gonçalves de Oliveira Ribeiro, José Dirceu Ribeiro
Respiratory Care Dec 2013, 58 (12) 2127-2133; DOI: 10.4187/respcare.02336

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Neonatal and Pediatric Manual Hyperinflation: Influence of Oxygen Flow on Ventilation Parameters
Pricila Mara Novais de Oliveira, Armando Augusto Almeida-Junior, Celize Cruz Bresciani Almeida, Maria Ângela Gonçalves de Oliveira Ribeiro, José Dirceu Ribeiro
Respiratory Care Dec 2013, 58 (12) 2127-2133; DOI: 10.4187/respcare.02336
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • resuscitation
  • manual hyperinflation
  • self-inflating bag
  • pediatric
  • respiratory therapy
  • Respiratory function monitor

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board
  • Reprints/Permissions

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire