Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
  • Log out
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleOriginal Research

Effect of High-Flow Nasal Cannula and Body Position on End-Expiratory Lung Volume: A Cohort Study Using Electrical Impedance Tomography

Jordi Riera, Purificación Pérez, Jordi Cortés, Oriol Roca, Joan Ramon Masclans and Jordi Rello
Respiratory Care April 2013, 58 (4) 589-596; DOI: https://doi.org/10.4187/respcare.02086
Jordi Riera
Critical Care Department, Vall d'Hebron Research Institut, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Purificación Pérez
Critical Care Department, Vall d'Hebron Research Institut, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jordi Cortés
Department of Statistics and Operations Research, Universitat Politècnica de Catalunya, Barcelona, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Oriol Roca
Critical Care Department, Vall d'Hebron Research Institut, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
Centro de Investigación Biomédica en Red Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Joan Ramon Masclans
Critical Care Department, Vall d'Hebron Research Institut, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
Centro de Investigación Biomédica en Red Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jordi Rello
Critical Care Department, Vall d'Hebron Research Institut, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
Centro de Investigación Biomédica en Red Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

BACKGROUND: Electrical impedance tomography measures changes in lung impedance, which are mainly related to changes in lung volume. We used electrical impedance tomography to investigate the effects of high-flow nasal cannula (HFNC) and body position on global and regional end-expiratory lung impedance variation (ΔEELI).

METHODS: Prospective study with 20 healthy adults. Two periods were defined: the first in supine position and the second in prone position. Each period was divided into 3 phases. In the first and the third phases the subjects were breathing ambient air, and in the second HFNC was implemented. Four regions of interest were defined: 2 ventral and 2 dorsal. For each respiratory cycle, global and regional ΔEELI were measured by electrical impedance tomography and were expressed as a function of the tidal variation of the first stable respiratory cycle (units).

RESULTS: HFNC increased global EELI by 1.26 units (95% CI 1.20–1.31, P < .001) in supine position, and by 0.87 units (95% CI 0.82–0.91, P < .001) in prone position. The distribution of ΔEELI was homogeneous in prone position, with no difference between ventral and dorsal lung regions (−0.01 units, 95% CI −0.01 to 0, P = .18), while in supine position a significant difference was found (0.22 units, 95% CI 0.21–0.23, P < .001) with increased EELI in ventral areas.

CONCLUSIONS: HFNC increased global EELI in our population, regardless of body position, suggesting an increase in functional residual capacity. Prone positioning was related to a more homogeneous distribution of ΔEELI, while in supine position ΔEELI was higher in the ventral lung regions.

  • high-flow nasal cannula
  • electrical impedance tomography
  • body position
  • lung volume
  • oxygen therapy
  • prone position

All men by nature desire to know.

—Aristotle, Metaphysics

Introduction

High-flow nasal cannula (HFNC) has been described as an excellent method of noninvasive oxygen delivery. In adult patients, warmed and humidified air can be delivered at up to 50 L/min, thus achieving a decrease in oxygen dilution,1–3 a reduction of respiratory dead space,2,4 and the generation of a certain degree of positive airway pressure.2,3,5–8 This therapy is very well tolerated by patients with acute respiratory failure9–14 and has become a highly effective noninvasive oxygen delivery device in adults as well as children.15–17 The possible mechanisms underlying this high efficacy of HFNC have been discussed,4,18 but, to our knowledge, only one recent published study has explored the effects of the therapy on lung volumes.19

Prone positioning is a maneuver that improves oxygenation and respiratory mechanics in mechanically ventilated patients with acute lung injury20–23 and may reduce mortality in patients with severe hypoxemia.24 The effects of this therapy on regional lung ventilation have been described in non-intubated healthy adult subjects25 and in preterm infants on CPAP,26 but its impact on lung volume distribution in adult subjects with HFNC therapy has not been discussed to date.

Electrical impedance tomography (EIT) is a noninvasive, non-ionizing, bedside method of monitoring bioimpedance changes related to different lung conditions, especially those related to regional ventilation.27–29 Interestingly, good correlations have been found between changes in end-expiratory lung impedance (EELI) and changes in end-expiratory lung volume (EELV),30,31 which is equivalent to functional residual capacity in non-intubated subjects. Another important feature of EIT is the possibility of assessing regional changes of impedance. The technique has been used to evaluate the local dynamic behavior of the lung in spontaneously breathing healthy subjects.25,32 Thus, EIT can provide information in a noninvasive manner about the changes in global and regional EELI associated with HFNC application in 2 different body positions.

The primary aims of this study were to compare the variation of global EELI associated with the high-flow application and to evaluate the influence of supine and prone position in regional impedance distribution. As a secondary aim, changes in breathing frequency between the different conditions were also measured, in view of the reports of a trend toward a decrease in the breathing frequency when HFNC is implemented.1,2,11–13,25

QUICK LOOK

Current knowledge

Heat and humidification of high-flow oxygen via nasal cannula improves patient comfort and allows the cannula to serve as a high-flow oxygen system. The impact of high nasal flow on airway pressures and end-expiratory lung volume remains unsettled.

What this paper contributes to our knowledge

High-flow oxygen via nasal cannula in healthy subjects increased the end-expiratory lung volume and reduced the breathing frequency in both the supine and prone positions. Prone positioning resulted in more even distribution of end-expiratory lung volume in normal subjects.

Methods

The study was conducted at the critical care department of the tertiary University Hospital of Vall d'Hebron in Barcelona. The study was approved by the ethics committee on January 10, 2011 (reference PR_AG_210–2010). Written informed consent was obtained from all subjects prior to the study.

Subjects

Twenty healthy volunteers were recruited. Exclusion criteria were age below 18 years, pregnancy, clinical evidence of respiratory illness, history of respiratory disease, body mass index over 50 kg/m2, and ribcage malformation. Height, weight, body mass index, and chest circumference were measured.

High-Flow Nasal Cannula Application

Totally conditioned medical air (FIO2 0.21) was delivered via HFNC (Optiflow, Fisher & Paykel Healthcare, Auckland, New Zealand) at a constant flow of 40 L/min. The humidifier (MR850, Fisher & Paykel Healthcare, Auckland, New Zealand) temperature was set to 37°C, and the air was delivered by silicon, medium sized nasal cannulae (RT050/051, Fisher & Paykel Healthcare, Auckland, New Zealand). Subjects were asked to breathe with mouth closed.

Electrical Impedance Tomography Measurement

EIT has been described as a reliable method of monitoring pulmonary ventilation. The technique uses injection of high frequency and low amplitude electrical currents through 16 electrodes around the thorax to generate cross-sectional images of the subject. Images of electrical impedance distribution are obtained from the resulting potential differences measured in the electrodes on the surface of the chest wall using a reconstruction algorithm. In the present study, EIT measurements were performed with the Pulmovista tomograph (Dräger Medical, Lübeck, Germany). The size of the rubber belt bearing the electrodes was selected according to the chest circumference measurement. The contact surface of the electrodes was wetted with alcohol. The belt was applied between the 4th and the 6th intercostal space. Self-test calibration was made by the system. Resistivity of each electrode was assessed. A high signal quality was necessary to start the measurements. The position of the subject was not changed during the period of measurement, because this might have caused changes in impedance unrelated to the maneuvers under study. A stable breath pattern was needed to start the study. The impedance variation was evaluated during each phase. The system measured the impedance changes of the thorax slide, which was divided into 4 regions of interest: right-ventral (region 1), left-ventral (region 2), right-dorsal (region 3), and left-dorsal (region 4). As impedance measurements are relative, a reference was needed to quantify the magnitude of the changes. The EELI variation (ΔEELI) of each respiratory cycle is expressed as a function of the tidal variation of the first stable respiratory cycle (units) of the first phase (Fig. 1).

Fig. 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.

As electrical impedance tomography measures variation of impedance values, a reference is needed to express the magnitude of the changes. The end-expiratory lung impedance variation (ΔEELI) of each respiratory cycle is expressed as a function of the tidal variation of the first stable respiratory cycle (VT global C1) of the first phase.

Study Procedures

Two different study periods were defined and performed on 2 different days, each one divided into 3 phases. First, the subjects were assessed in supine position, breathing with the mouth closed. The electrical impedance tomograph was applied. After 2 min breathing ambient air, HFNC was applied for 4 min. Finally, another 2-min phase breathing ambient air completed this first study period. In each phase, global and regional ΔEELI were measured as previously described. Since the clinical effects of HFNC are usually immediate and maintained over time, we designed the study with short exposure periods of time. Breathing frequency was also recorded. The same subjects were assessed in the second period of the study, this time assessed in prone position, breathing with the mouth closed. The period was also divided into the 3 phases described above. Global and regional ΔEELI and breathing frequency measurements were made. Means of global and regional ΔEELI in each phase were compared.

Statistical Analysis

The values are presented as mean ± SD. A mixed-effect regression model was used to assess the mean changes in EELI. An unstructured covariance matrix was used to describe the repeated measures in each subject. Changes in breathing frequency (only one determination per subject, phase, and period) were estimated with a paired t test, and we report the 95% confidence intervals for the differences. Significance was set at a 2-tailed P value of .05. All analyses were performed using statistical software (R 11.1, R Foundation for Statistical Computing, Vienna, Austria).

Results

The characteristics of the 20 healthy volunteers are shown in the Table. There were major difficulties in obtaining a correct EIT signal in subject 11 because of incorrect belt fitting, so the data derived were not included in the analysis. Subject 14 was unable to be contacted during the second period of the study. No adverse effects were observed during HFNC use.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table.

Characteristics of the Population

There were 41.02 ± 15.97 measurements of ΔEELI per subject in the first period of the study, with subjects breathing in supine position, and 30.63 ± 11.84 measurements in the second period of the study, with subjects breathing in prone position.

Global ΔEELI

In supine position, HFNC increased global EELI by 1.26 units (95% CI 1.20–1.31, P < .001), compared to the first phase of ambient air breathing. Comparing the second phase and the third (ambient air breathing), there was a significant decrease in global EELI (1.30, 95% CI 1.25–1.35, P < .001) (Fig. 2).

Fig. 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.

Global end-expiratory lung impedance variation (ΔEELI) in the supine and prone positions while breathing ambient air (phases 1 and 3) versus on high-flow nasal cannula (phase 2). ΔEELI is higher during the ambient air phases.

In prone position, similar changes in global ΔEELI with HFNC were observed. During the HFNC phase an increase in global EELI of 0.87 units (95% CI 0.82–0.91, P < .001) was observed. Moreover, a decrease of 1.03 units (95% CI 0.98–1.08, P < .001) was found between the second HFNC phase and the third ambient air phase (see Fig. 2).

Regional ΔEELI

In supine position, higher values of regional EELI were observed in the ventral lung regions (Fig. 3), comparing the first ambient air phase and the HFNC phase. Comparing the ΔEELI of these ventral areas (region 1 and region 2) with the ΔEELI of the dorsal areas (region 3 and region 4), a significant difference was found (0.22 units, 95% CI 0.21–0.23, P < .001, Fig. 4).

Fig. 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 3.

Regional end-expiratory lung impedance variation (ΔEELI) in the supine position. Regional ΔEELI is higher in the ventral regions (1 and 2).

Fig. 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 4.

Image, curves, and numbers of global and regional end-expiratory lung impedance variation (ΔEELI) of a subject breathing in supine position. There is a substantial difference between the ventral (1 and 2) and dorsal (3 and 4) lung regions.

A more homogeneous pattern of regional EELI variation was observed in prone position, with a lower increase in EELI in the ventral regions (Fig. 5). In this position, no significant differences in ΔEELI were evidenced when comparing ventral and dorsal areas (−0.01 units, 95% CI −0.01, 0, P = .18) (Fig. 6).

Fig. 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 5.

Regional end-expiratory lung impedance variation (ΔEELI) in the prone position. Note the more homogeneous ΔEELI distribution.

Fig. 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 6.

Image, curves, and numbers of global and regional end-expiratory lung impedance variation (ΔEELI) in the prone position. Note the more homogeneous ΔEELI distribution.

Breathing Frequency

A decrease in the breathing frequency was observed between the first and the second phases in both periods. In the supine position there was a mean decrease of 2.73 breaths/min (95% CI 0.4–5.08, P = .02). In the prone position a mean decrease of 7.89 breaths/min (95% CI 4.38–11.4, P < .001) was observed. In the supine position there was no significant difference in breathing frequency between the second (HFNC) and the third (ambient air) phases (0.10 breaths/min, 95% CI −2.17 to 2.38, P = .92), but in prone position the breathing frequency of the third phase was 2.22 breaths/min (95% CI 0.83–3.61, P = .003), higher than the second phase.

Discussion

These data demonstrate that the noninvasive application of HFNC increases EELI in healthy subjects, suggesting an increase in the functional residual capacity. This increase is significantly higher in the ventral lung regions when the subject is breathing in supine position; the distribution is more homogeneous when breathing in the prone position. To our knowledge, this is the first study reporting the effects of body position in impedance distribution in subjects with high-flow therapy. Furthermore, we also observed a decrease in the breathing frequency associated with the HFNC application.

There was a significant increase in global EELI, comparing breathing ambient air and breathing with HFNC, in both supine and prone positions. A good correlation has been previously demonstrated between changes in lung impedance measured by EIT and changes in lung volume,30,33–37 suggesting that the application of high-flow therapy could increase functional residual capacity. This finding was already reported in a recent study,19 where HFNC significantly increased global EELI in a population of post-cardiac surgery patients with respiratory dysfunction. This effect is reversible, given that significant differences between the second phase (HFNC) and the third phase (ambient air) were observed. This increment of global EELI could be explained by the previously demonstrated generation of positive airway pressure when HFNC is applied2,3,5–8,19 In fact, a strong and significant correlation between airway pressure and EELI during HFNC use has been recently described.19 This positive airway pressure achieved correlates with flow administered, being up to 7 cm of H2O with 50 L/min.2,7 There are more outlier values observed in the HFNC measurements, regardless of body position (see Fig. 2). These outliers match with the first measurements done in the second phase. When the HFNC system is applied, it takes a few respiratory cycles to reach a stable breath pattern.

We demonstrated a significant difference in the distribution of the ΔEELI when comparing the application of HFNC in supine and prone position. In supine position the regional ΔEELI of the ventral regions of the lung parenchyma was significantly higher than the regional ΔEELI of the dorsal regions. This fact was not observed when the subject was in prone position, in which ΔEELI distribution is more homogeneous. This finding is consistent with a previous report on prone positioning in ARDS-affected mechanically ventilated patients.38 In these patients, prone position may induce a more homogeneous distribution of transpulmonary pressure, and hence of alveolar inflation, although patients' conditions could be different from those of our population. Diaphragm movement in spontaneously breathing subjects plays an essential role in alveolar inflation distribution, a condition that is usually minimized with mechanically ventilated patients in prone position.

Riedel and co-workers assessed the effect of prone positioning with EIT in spontaneously breathing subjects, where a continuous positive airway pressure (CPAP) was applied,25 observing that in supine position ventilation in the dorsal regions remained unchanged from 0 to 10 cm H2O CPAP, but increased in the ventral areas, while in prone position the ventral regions showed reduced ventilation at 10 cm H2O CPAP. This tendency toward a more heterogeneous ventilation pattern in the supine position was also demonstrated in an animal model ventilated with a PEEP of 10 cm H2O, while ventilating in prone position eliminated the dorsal-to-ventral gradient.39 All these results are consistent with our findings, as we noted a higher EELI increase in the non-dependent lung regions in the supine position than in the dependent regions. This homogeneity of air distribution may be of interest in hypoxemic patients, in whom prone positioning could improve the oxygenation efficacy of the high-flow oxygen therapy, since it has been suggested that response in PaO2 is associated with a more homogeneous regional inflation.40 Furthermore, better oxygenation has been recently described as a predictor of HFNC treatment success.12

These findings in healthy subjects, if confirmed in hypoxemic patients, would be of interest in high-flow treatment. Prone positioning in this population could improve oxygen therapy efficacy. However, 2 issues should be assessed in hypoxemic patients. First, tolerability of the prone position of patients with a high work of breathing, and, second, the consequences of this more homogeneous pattern on gas exchange and on alveolar stress and strain in the injured lung. Moreover, the degree of alveolar recruitability of HFNC therapy could change, depending on the lung pathology. It would also be interesting to evaluate the relationship between the magnitude of this EELI increase and the degree of the associated clinical changes. For this purpose, the ΔEELI/Δlung volume relation should be calculated with a nitrogen wash-out maneuver.30 These questions should be examined on further investigations that could contribute to the growing body of information regarding HFNC therapy.

A significant decrease in the breathing frequency was observed when HFNC was implemented, in both body positions. This finding is consistent with results observed in previous studies that included patients with acute respiratory failure,1,2,11–13,25 where this decrease in breathing frequency was not associated with hypercapnic acidosis.11–13 Different reasons may explain these results. The first explanation that may partially explain this fact is the reduction of the anatomic dead space generated by the continuous administration of high flow of gas, known as wash-out effect.2,4,18 More importantly, the reduction in breathing frequency may be a consequence of an increase in tidal volume. In this sense, a similar decrease in breathing frequency and an increase in tidal volume inferred by the tidal impedance variation when HFNC was applied have been previously reported.19

Our study has certain limitations. Some are inherent to the EIT technique. We estimated changes in EELV by changes in EELI. Bikker et al found that this correlation was significant but relatively low (r = 0.79, R2 = 0.62).41 However, in this study a PEEP trial was performed, so potential thorax geometry changes and craniocaudal thorax structure movements could distort Δimpedance measurements. On the other hand, Erlandsson et al found good agreement between tidal impedance variation and tidal volume (R2 = 0.95),42 Richard et al validated EIT as a regional lung ventilation monitor by positron-emission tomography in healthy individuals with a coefficient of determination of 0.63,37 and Hinz et al also described good agreement between changes in EELV and changes in EELI (R2 = 0.95) measuring impedance and lung volume with an open circuit nitrogen washout technique.30 The measurement of EIT reflects only a single cross-sectional slice of the lung, so the rest of the organ is ignored. Moreover, thorax shape can contribute as much as lung volume to thoracic impedance.28 However, as the system records relative measurements and not absolute impedance distribution, the impedance changes are related to lung volume changes, as chest wall impedance remains relatively constant. Therefore, a reference is needed; in this study we used the tidal impedance variation of the first stable respiratory cycle.

In some subjects the application of the electrode belt may present technical difficulties. We found problems in only one subject, due to the loosening of the contact between 2 electrodes and the skin during the breathing movements. The values derived from these EIT measurements were not reliable, so they were excluded from the analysis. Moreover, another subject completed only the supine period of the study, so comparison of supine versus prone was done with a sample size of 18 subjects. Finally, the findings of this study are conclusive but limited to healthy subjects. However, to our knowledge, this is the first study about the effect of prone positioning in EELI of subjects with high-flow nasal therapy. Whether similar findings are found in subjects with lung disease should be confirmed in further studies.

Conclusions

We conclude that the application of noninvasive HFNC in healthy subjects significantly increases their EELI, a fact that suggests an increment of functional residual capacity in both supine and prone positions. HFNC application decreases the breathing frequency in both positions. Prone positioning homogenizes the distribution of ΔEELI in these subjects. The evidence of these findings in our population may help to develop new management strategies for hypoxemic patients receiving high-flow oxygen therapy.

Footnotes

  • Correspondence: Jordi Riera MD, Critical Care Department, Vall d'Hebron Research Institut, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Paseo Vall d'Hebron 119-129, 08035 Barcelona, Spain. E-mail: jorriera{at}vhebron.net.
  • Dr Riera presented a version of this paper at the 25th Annual Congress of the European Society of Intensive Care Medicine, held October 13–17, 2012, in Lisbon, Portugal.

  • Drs Masclans and Roca have disclosed relationships with Fisher & Paykel. The other authors have disclosed no conflicts of interest.

  • See the Related Editorial on Page 715

  • Copyright © 2013 by Daedalus Enterprises

References

  1. 1.↵
    1. Lund J,
    2. Holm-Knudsen RJ,
    3. Nielsen J,
    4. Føge Jensen PB
    . [Nasal catheters versus Hudson face mask in oxygen therapy]. Ugeskr Laeger 1996;158(28):4077-4079. Article in Danish.
    OpenUrlPubMed
  2. 2.↵
    1. Chatila W,
    2. Nugent T,
    3. Vance G,
    4. Gaughan J,
    5. Criner GJ
    . The effects of high-flow vs low-flow oxygen on exercise in advanced obstructive airways disease. Chest 2004;126(4):1108-1115.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Williams AB,
    2. Ritchie JE,
    3. Gerard C
    . Evaluation of a high-flow nasal oxygen delivery system: gas analysis and pharyngeal pressures. Intensive Care Med 2006;32(Suppl 1):S219.
    OpenUrl
  4. 4.↵
    1. Dysart K,
    2. Miller TL,
    3. Wolfson MR,
    4. Shaffer TH
    . Research in high-flow therapy. Mechanisms of action. Respir Med 2009;103(10):1400-1405.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Groves N,
    2. Tobin A
    . High flow nasal oxygen generates positive airway pressure in adult volunteers. Aust Crit Care 2007;20(4):126-131.
    OpenUrlCrossRefPubMed
  6. 6.
    1. Kubicka ZJ,
    2. Limauro J,
    3. Darnall RA
    . Heated, humidified high-flow nasal cannula therapy: yet another way to deliver continuous positive airway pressure? Pediatrics 2008;121(1):82-88.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Parke RL,
    2. McGuinness SP,
    3. Eccleston ML
    . Nasal high-flow therapy delivers low level positive airway pressure. Br J Anaesth 2009;103(6):886-890.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Parke RL,
    2. Eccleston ML,
    3. McGuinness SP
    . The effects of flow on airway pressure during nasal high-flow oxygen therapy. Respir Care 2011;56(8):1151-1155.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Tatjana P,
    2. Calvano DO,
    3. Sill JM,
    4. Kemp KR,
    5. Chung KK
    . Use of a high-flow oxygen delivery system in a critically ill patient with dementia. Respir Care 2008;53(12):1739-1743.
    OpenUrlAbstract/FREE Full Text
  10. 10.
    1. Tiruvoipati R,
    2. Lewis D,
    3. Haji K,
    4. Botha J
    . High-flow nasal oxygen vs high-flow face mask: a randomized crossover trial in extubated patients. J Crit Care 2010;25(3):463-468.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Roca O,
    2. Riera J,
    3. Torres F,
    4. Masclans JR
    . High-flow oxygen therapy in acute respiratory failure. Respir Care 2010;55(4):408-413.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    1. Sztrymf B,
    2. Messika J,
    3. Bertrand F,
    4. Hurel D,
    5. Leon R,
    6. Dreyfuss D,
    7. Ricard JD
    . Beneficial effects of humidified high flow nasal oxygen in critical care patients: a prospective pilot study. Intensive Care Med 2011;37(11):1780-1786.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Sztrymf B,
    2. Messika J,
    3. Mayot T,
    4. Lenglet H,
    5. Dreyfuss D,
    6. Ricard JD
    . Impact of high-flow nasal cannula oxygen therapy on intensive care unit patients with acute respiratory failure: a prospective observational study. J Crit Care 2011;27(3):324.e9-e13.
    OpenUrl
  14. 14.↵
    1. Parke RL,
    2. McGuinness SP,
    3. Eccleston ML
    . A preliminary randomized controlled trial to assess effectiveness of nasal high-flow oxygen in intensive care patients. Respir Care 2011;56(3):265-270.
    OpenUrlAbstract/FREE Full Text
  15. 15.↵
    1. Holleman-Duray D,
    2. Kaupie D,
    3. Weiss MG
    . Heated humidified high-flow nasal cannula: use and a neonatal early extubation protocol. J Perinatol 2007;27(12):776-781.
    OpenUrlCrossRefPubMed
  16. 16.
    1. Woodhead DD,
    2. Lambert DK,
    3. Clark JM,
    4. Christensen RD
    . Comparing two methods of delivering high-flow gas therapy by nasal cannula following endotracheal extubation: a prospective, randomized, masked, crossover trial. J Perinatol 2006;26(8):481-485.
    OpenUrlCrossRefPubMed
  17. 17.↵
    1. Dani C,
    2. Pratesi S,
    3. Migliori C,
    4. Bertini G
    . High flow nasal cannula therapy as respiratory support in the preterm infant. Pediatr Pulmonol 2009;44(7):629-634.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. Masclans JR,
    2. Roca O
    . High flow oxygen therapy in acute respiratory failure. Clin Pulm Med 2012;19(3):127-130.
    OpenUrl
  19. 19.↵
    1. Corley A,
    2. Caruana LR,
    3. Barnett AG,
    4. Tronstad O,
    5. Fraser JF
    . Oxygen delivery through high-flow nasal cannulae increase and-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients. Br J Anaesth 2011;107(6):998-1004.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    1. Piehl MA,
    2. Brown RS
    . Use of extreme position changes in acute respiratory failure. Crit Care Med 1976;4(1):13-14.
    OpenUrlCrossRefPubMed
  21. 21.
    1. Douglas WW,
    2. Rehder K,
    3. Beynen FM,
    4. Sessler AD,
    5. Marsh HM
    . Improved oxygenation in patients with acute respiratory failure: the prone position. Am Rev Respir Dis 1977;115(4):559-566.
    OpenUrlPubMed
  22. 22.
    1. Curley MA
    . Prone positioning of patients with acute respiratory distress syndrome: a systematic review. Am J Crit Care 1999;8(6):397-405.
    OpenUrlAbstract
  23. 23.↵
    1. Malhotra A,
    2. Ayas N,
    3. Kacmarek RM
    . Prone positioning of patients in acute respiratory failure. N Engl J Med 2002;346(4):295-297.
    OpenUrl
  24. 24.↵
    1. Sud S,
    2. Friedrich JO,
    3. Taccone P,
    4. Polli F,
    5. Adhikari NK,
    6. Latini R,
    7. et al
    . Prone ventilation reduces mortality in patients with acute respiratory failure and severe hypoxemia: systematic review and meta-analysis. Intensive Care Med 2010;36(4):585-599.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Riedel T,
    2. Richards T,
    3. Schibler A
    . The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects. Intensive Care Med 2005;31(11):1522-1528.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Hough JL,
    2. Johnston L,
    3. Brauer SG,
    4. Woodgate PG,
    5. Pham TM,
    6. Schibler A
    . Effect of body position on ventilation distribution in preterm infants on continuous positive airway pressure. Pediatr Crit Care Med 2012;13(4):446-451.
    OpenUrlPubMed
  27. 27.↵
    1. Frerichs I
    . Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities. Physiol Meas 2000;21(2):R1-R21.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Costa EL,
    2. Lima RG,
    3. Amato MB
    . Electrical impedance tomography. Curr Opin Crit Care 2009;15(1):18-24.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Riera J,
    2. Riu PJ,
    3. Casan P,
    4. Masclans JR
    . [Electrical impedance tomography in acute lung injury]. Medicina Intensiva 2011;35(8):509-517. Article in Spanish.
    OpenUrlPubMed
  30. 30.↵
    1. Hinz J,
    2. Hahn G,
    3. Neumann P,
    4. Sydow M,
    5. Mohrenweiser P,
    6. Hellige G,
    7. Burchardi H
    . End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change. Intensive Care Med 2003;29(1):37-43.
    OpenUrlPubMed
  31. 31.↵
    1. Moerer O,
    2. Hahn G,
    3. Quintel M
    . Lung impedance measurements to monitor alveolar ventilation. Curr Opin Crit Care 2011;17(3):260-267.
    OpenUrlPubMed
  32. 32.↵
    1. Hahn G,
    2. Frerichs I,
    3. Kleyer M,
    4. Hellige G
    . Local mechanics of the lung tissue determined by functional EIT. Physiol Meas 1996;17(Suppl 4A):A159-A166.
    OpenUrlCrossRefPubMed
  33. 33.↵
    1. Adler A,
    2. Amyot R,
    3. Guardo R,
    4. Bates JH,
    5. Berthiaume Y
    . Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J Appl Physiol 1997;83(5):1762-1767.
    OpenUrlAbstract/FREE Full Text
  34. 34.
    1. Hinz J,
    2. Neumann P,
    3. Dudykkevych T,
    4. Andersson LG,
    5. Wrigge H
    . Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs. Chest 2003;124(1):314-322.
    OpenUrlCrossRefPubMed
  35. 35.
    1. Victorino JA,
    2. Borges JB,
    3. Okamoto VN,
    4. Matos GF,
    5. Tucci MR,
    6. Caramez MP,
    7. et al
    . Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. Am J Respir Crit Care Med 2004;169(7):791-800.
    OpenUrlCrossRefPubMed
  36. 36.
    1. Marquis F,
    2. Coulombe N,
    3. Costa R,
    4. Gagnon H,
    5. Guardo R,
    6. Skrobik Y
    . Electrical impedance tomography's correlation to lung volume is not influenced by anthropometric parameters. J Clin Monit Comput 2006;20(3):201-207.
    OpenUrlPubMed
  37. 37.↵
    1. Richard JC,
    2. Pouzot C,
    3. Gros A,
    4. Tourevieille C,
    5. Lebars D,
    6. Lavenne F,
    7. et al
    . Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study. Crit Care 2009;13(3):R82.
    OpenUrlCrossRefPubMed
  38. 38.↵
    1. Pelosi P,
    2. Brazzi L,
    3. Gattinoni L
    . Prone position in acute respiratory distress syndrome. Eur Respir J 2002;20(4):1017-1028.
    OpenUrlAbstract/FREE Full Text
  39. 39.↵
    1. Johansson MJ,
    2. Wiklund A,
    3. Flatebø T,
    4. Nicolaysen A,
    5. Nicolaysen G,
    6. Walther SM
    . Positive end-expiratory pressure affects regional redistribution of ventilation differently in prone and supine sheep. Crit Care Med 2004;32(10):2039-2044.
    OpenUrlCrossRefPubMed
  40. 40.↵
    1. Tobin MJ
    1. Gattinoni L,
    2. Valenza F,
    3. Pelosi P,
    4. Mascheroni D
    . Prone positioning in acute respiratory failure. In: Tobin MJ, editor. Principles and practice of mechanical ventilation, 2nd edition. New York: McGraw-Hill; 2006:1081-1091.
  41. 41.↵
    1. Bikker IG,
    2. Leonhardt S,
    3. Bakker J,
    4. Gommers D
    . Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels. Intensive Care Med 2009;35(8):1362-1367.
    OpenUrlPubMed
  42. 42.↵
    1. Erlandsson K,
    2. Odenstedt H,
    3. Lundin S,
    4. Stenqvist O
    . Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery. Acta Anaesthesiol Scand 2006;50(7):833-839.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Respiratory Care: 58 (4)
Respiratory Care
Vol. 58, Issue 4
1 Apr 2013
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
  • Monthly Podcasts

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Effect of High-Flow Nasal Cannula and Body Position on End-Expiratory Lung Volume: A Cohort Study Using Electrical Impedance Tomography
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Effect of High-Flow Nasal Cannula and Body Position on End-Expiratory Lung Volume: A Cohort Study Using Electrical Impedance Tomography
Jordi Riera, Purificación Pérez, Jordi Cortés, Oriol Roca, Joan Ramon Masclans, Jordi Rello
Respiratory Care Apr 2013, 58 (4) 589-596; DOI: 10.4187/respcare.02086

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Effect of High-Flow Nasal Cannula and Body Position on End-Expiratory Lung Volume: A Cohort Study Using Electrical Impedance Tomography
Jordi Riera, Purificación Pérez, Jordi Cortés, Oriol Roca, Joan Ramon Masclans, Jordi Rello
Respiratory Care Apr 2013, 58 (4) 589-596; DOI: 10.4187/respcare.02086
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • High-flow nasal cannula
  • electrical impedance tomography
  • body position
  • lung volume
  • oxygen therapy
  • prone position

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire