Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleOriginal Research

Home Unattended Portable Monitoring and Automatic CPAP Titration in Patients with High Risk for Moderate to Severe Obstructive Sleep Apnea

Ersilia Tedeschi, Pierluigi Carratù, Mario Francesco Damiani, Valentina Anna Ventura, Riccardo Drigo, Edda Enzo, Alberto Ferraresso, Geo Sasso, Franco Maria Zambotto and Onofrio Resta
Respiratory Care July 2013, 58 (7) 1178-1183; DOI: https://doi.org/10.4187/respcare.01939
Ersilia Tedeschi
Institute of Respiratory Disease, University of Bari, Bari, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pierluigi Carratù
Institute of Respiratory Disease, University of Bari, Bari, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Mario Francesco Damiani
Institute of Respiratory Disease, University of Bari, Bari, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Valentina Anna Ventura
Institute of Respiratory Disease, University of Bari, Bari, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Riccardo Drigo
Center of Sleep Breathing Medicine, Unità Operativa Complessa de Pneumologie, Hospital Santa Maria del Prato, Feltre, Belluno, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Edda Enzo
Center of Sleep Breathing Medicine, Unità Operativa Complessa de Pneumologie, Hospital Santa Maria del Prato, Feltre, Belluno, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alberto Ferraresso
Center of Sleep Breathing Medicine, Unità Operativa Complessa de Pneumologie, Hospital Santa Maria del Prato, Feltre, Belluno, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Geo Sasso
Center of Sleep Breathing Medicine, Unità Operativa Complessa de Pneumologie, Hospital Santa Maria del Prato, Feltre, Belluno, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Franco Maria Zambotto
Center of Sleep Breathing Medicine, Unità Operativa Complessa de Pneumologie, Hospital Santa Maria del Prato, Feltre, Belluno, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Onofrio Resta
Institute of Respiratory Disease, University of Bari, Bari, Italy.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND: Obstructive sleep apnea is a disorder characterized by recurrent obstruction of the upper airways during sleep. The high prevalence of this disease led to proposed new strategies based on the home evaluation and management of patients.

OBJECTIVE: To compare home unattended portable monitoring and automatic CPAP titration with attended in-laboratory analysis, in a sample of patients with high risk for moderate to severe obstructive sleep apnea.

METHODS: We enrolled 131 subjects, who were randomly divided into 2 groups: the home group (n = 66) was diagnosed and titrated at home; the laboratory group (n = 65) was analyzed in the sleep laboratory of our hospital. Diagnostic evaluations were carried out with portable monitoring at home, and with polysomnography in the sleep laboratory. Titration of CPAP was performed with the same automatic CPAP device in both groups.

RESULTS: At the end of the study, 13 (19%) subjects had dropped out of the home group, and 9 (14%) of the laboratory group (P = .50). There were no significant differences among groups in both baseline and with-CPAP values of apnea-hypopnea index, oxygen desaturation index, and total sleep time with SpO2 below 90%. In the home group, the therapeutic pressure values reached at the end of each unattended home titration night were similar.

CONCLUSIONS: A home diagnosis and titration approach should be considered in a subset of patients with obstructive sleep apnea. A single unattended titration night is sufficient to determine the therapeutic pressure.

  • obstructive sleep apnea
  • OSA
  • CPAP
  • automatic CPAP titration
  • home titration
  • portable monitoring

Introduction

Obstructive sleep apnea (OSA) is a disorder characterized by recurrent obstruction of the upper airway during sleep, resulting in intermittent oxygen desaturation, daytime sleepiness, and decreased quality of life. The standard approach to diagnosis and titration of patients with suspected OSA consists of polysomnography (PSG), followed by manual titration of CPAP during attended PSG.1,2 OSA is a highly prevalent disease: in 1993, Young et al3 reported that moderate to severe OSA affects 4% of adult women and 9% of adult men, and a large proportion of these people are undiagnosed. These results likely underestimate the current prevalence of OSA due to an important increase in obesity over the past 2 decades.4 The prevalence of this disease and its association with the onset of hypertension,5,6 cardiovascular diseases,7 stroke,8,9 increased motor vehicle accidents,10 and mortality9 have made it a major public health issue. On the other hand, patient wait time for in-laboratory attended PSG in many public healthcare systems is often too long; indeed, it can exceed 6 months.11 Moreover, in-laboratory PSG is expensive and time consuming.12 All these reasons led to proposal of new strategies based on the home evaluation and management of patients.13 Indeed, home portable monitoring is a cheap and easily accessible test.12 With regard to titration, there is evidence that certain automatic CPAP devices may be used at home to determine the therapeutic pressure.2 However, some doubts remain about this practice; in fact, the available evidence still cannot support a guideline recommendation.2 The aim of this study was to compare home unattended portable monitoring and automatic CPAP titration to an attended in-laboratory program, in a sample of patients with high risk for moderate to severe OSA.

QUICK LOOK

Current knowledge

Obstructive sleep apnea is characterized by recurrent obstruction of the upper airway during sleep, resulting in intermittent hypoxemia, daytime sleepiness, and decreased quality of life. The standard diagnosis of suspected obstructive sleep apnea consists of attended polysomnography, followed by manual PEEP titration.

What this paper contributes to our knowledge

In selected patients, home unattended sleep monitoring and automatic PEEP titration resulted in similar PEEP level, apnea-hypopnea index, oxygen desaturation index, and hypoxemia. A single unattended PEEP titration is sufficient to determine the therapeutic PEEP.

Methods

Subjects

Between June 2008 and September 2009 we enrolled 131 subjects who were referred for their first sleep study for suspicion of OSA to our sleep center in the pulmonology section at Hospital Santa Maria del Prato, Feltre, Belluno, Italy. The inclusion criteria were:

  • High suspicion of OSA, based on excessive daytime sleepiness (Epworth Sleepiness Scale score ≥ 10), history of habitual snoring, witnessed apneas, and oxygen desaturation index > 30, assessed during home night oximetry (Pulsox3i, Minolta, Tokyo, Japan)

  • Absence of cardiovascular, respiratory, and neuromuscular comorbidities

  • Subject lived within 100 km of the hospital

Design of the Study

This work was a randomized, prospective study, with 2 parallel arms. The demographic characteristics and Epworth Sleepiness Scale scores are shown in Table 1, with no differences between groups. Subjects were randomly divided into 2 groups: the home group (n = 66) was diagnosed and titrated at home; the laboratory group (n = 65) was evaluated in the sleep laboratory of our hospital. The randomization assignments were computer generated, using a block permutation method to select 1 of the 2 diagnostic and titration alternatives. Randomization was performed by the staff of our hospital, who had no direct participation in the study. Subjects in the home group were examined at home with a portable monitoring device. To assess the reliability of portable monitoring we evaluated the quality of the 3 main signals: oxygen saturation, thoracic/abdominal movements, and nasal air flow. If the subject required CPAP (apnea-hypopnea index [AHI] ≥ 5 events/h) according to the international guidelines,14 he or she underwent unattended home automatic CPAP titration during 4 consecutive nights. To confirm the therapeutic pressure reached during automatic CPAP titration, the subject then underwent attended PSG with CPAP in the sleep laboratory. In all subjects we applied a pressure that represented the mean value from the pressures determined at the end of each night. The laboratory group was diagnosed with overnight PSG in the sleep laboratory. If the circumstances mentioned above for the home group were present, the laboratory group subject was titrated with automatic CPAP during one night in the laboratory. In the home group the therapeutic pressure was tested during PSG with CPAP in the laboratory. In both groups, all the diagnostic and therapeutic evaluations were performed during consecutive nights.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1.

Demographic Characteristics of Subjects

Methods

PSG was performed in the laboratory, using a recording device (Grass-Telefactor, Astro-Med, West Warwick, Rhode Island). The following signals were measured: nasal air flow (nasal cannula and thermocouple), thoracic and abdominal movements, arterial oxygen saturation, electrocardiogram, body position, and snoring.

The portable monitor used at home (Somtè PSG, Compumedics, Abbotsford, Victoria, Australia) recorded the following signals: nasal air flow, thoracic and abdominal movements, arterial oxygen saturation, electrocardiogram, body position, and snoring.

In the attended laboratory studies, a clinical laboratory technician provided continuous monitoring of parameters to identify and correct any sensor loss. Portable monitoring and PSG recordings were interpreted by 2 sleep medicine physicians, according to the Associazione Italiana Pneumologi Ospedalieri guidelines.15

An AHI ≥ 5 was necessary to diagnose OSA.14 Neither the PSG nor the portable monitoring were considered reliable if the quality of one of the main signals (oxygen saturation, thoracic/abdominal movements, nasal air flow) was poor for more than 20% of the recording time.

The home and laboratory titration of CPAP were performed with the same automatic CPAP device (RemStar Auto, Respironics, Murrysville, Pennsylvania). Each machine was used with the default settings, with the lower and upper pressure bounds set to 4 and 16 cm H2O, respectively. According to the manufacturer's instructions, the reference pressure level was the 90th percentile of the pressure determined by the device. Information recorded by the automatic CPAP device was examined by a sleep medicine physician. The recording was considered acceptable if the recording duration was at least 3 hours, and leaks were not present for more than 20% of the recording time, according to the manufacturer's instructions. In the home group the therapeutic pressure was considered reliable if we had at least 2 days of recording. Before titration, subjects in both groups received a demonstration, from a nurse, of the procedures to operate the machine and install the mask, and 20 min acclimatization session of automatic CPAP, during an afternoon session.

The study was approved by the institutional review board of Bari University General Hospital, and carried out in accordance with the principles of the Helsinki Declaration. All subjects gave prior written informed consent to take part in the study.

Statistical Analysis

Data are presented as mean ± SD unless otherwise indicated. Differences between groups were analyzed with the Student t test for independent samples. To compare the therapeutic pressure values determined during the 4-night home titration, analysis of variance was performed. A value of P < .05 was considered statistically significant. The analyses were made using statistics software (Statistica 6.1, StatSoft, Tulsa, Oklahoma).

Results

The Figure shows the study flow chart. We enrolled 131 subjects. In the home group, 2 subjects' data were excluded because of poor quality portable monitoring. In addition, 4 subjects did not agree to undergo unattended automatic CPAP titration: 2 because of incapacity to wear the mask (claustrophobia), and 2 due to non-acceptance of long-term treatment. Seven did not complete the home titration of CPAP, due to: the automatic CPAP recording was not considered acceptable, due to excessive leakage (3 subjects); complaint of nasal stuffiness (2 subjects); mask discomfort (2 subjects).

Figure.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure.

Study flow chart.

In the laboratory group the quality of baseline PSG was good in all cases, but 3 subjects were excluded: 2 because they were diagnosed with central sleep apnea, and 1 was found not to need CPAP (AHI < 5 events/h). All the subjects underwent attended automatic CPAP titration, but 9 did not complete the laboratory titration, due to failure to fall asleep (3 subjects), dry mouth (3 subjects), nasal stuffiness (2 subjects), and mask discomfort (1 subject). The percentage of reliable baseline portable monitoring and PSG was similar between groups: 97% (64/66) in the home group versus 100% (65/65) in the laboratory group (P = .48). In the home group, 17% (11/64) of subjects refused CPAP before or during titration, with similar results in the laboratory group (14%, 9/62, P = .86). At the end of the study, 13 (19%) subjects had dropped out of the home group, and 9 (14%) of the laboratory group, with no significant differences between groups (P = .50). The remaining 106 completed the program. The therapeutic pressure values determined by automatic CPAP titration were not different between the groups: 13.3 ± 1.7 cm H2O was the mean value of the pressures determined at the end of 4 unmonitored titration nights, and 13.5 ± 1.3 cm H2O was the mean value of the pressures determined after a single titration night in the laboratory (P = .49).

The therapeutic pressure values determined at the end of each unattended home titration night had no statistical differences between the nights: 13.2 ± 1.7 cm H2O, 13.4 ± 1.7 cm H2O, 13.1 ± 1.6 cm H2O, and 13.5 ± 1.7 cm H2O, P = .59. This means that the pressures determined during any of the 4 unattended titration nights were similar to those determined during the one attended in-laboratory titration night. Table 2 shows the baseline and with-CPAP values of AHI, oxygen desaturation index, and total sleep time with SpO2 < 90%. There were no significant differences between the groups.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 2.

Sleep Parameters at Baseline and With CPAP

The number of subjects with severe OSA (AHI > 30 events/h) was 50 in the home group and 51 in the laboratory group (P > .99). The AHI normalized (< 5 events/h) in the home group in all but 3 subjects, and in the laboratory group in all but 2 (P > .99). The baseline sleep characteristics of subjects who did not undergo/complete automatic CPAP titration were similar to those who reached the end of the study (data not shown).

Discussion

This study demonstrated that for individuals with high risk of OSA, the home unattended diagnostic/therapeutic program is as effective as the hospital attended evaluation. With regard to the diagnosis of OSA, although the PSG is the gold standard,1 over the last decade it has widely been demonstrated that home portable monitoring is a valid and reliable test.16,17 Furthermore, recently, the Portable Monitoring Task Force of the American Academy of Sleep Medicine recommended that portable monitoring should be limited to subjects with a high risk for moderate to severe OSA,18 such as in our work. In agreement with the literature,19 3% of the home portable monitoring was not reliable, with no significant differences between groups. As far as the titration is concerned, home unattended automatic CPAP represents a useful and accurate way to identify conventional CPAP setting outside the hospital.

Sériès is one of the pioneers of the home-based protocol. In his work,20 dating back to 2000, a 1- or 2-week home automatic CPAP trial was done in 40 subjects, by establishing the reference pressure to be set on a fixed CPAP machine for 2 additional weeks, plus a control PSG with fixed CPAP. A significant improvement was demonstrated in sleep architecture and AHI, with normalization in almost all subjects, encouraging subsequent research. Later, other studies comparing in-laboratory manual titration to unattended automatic CPAP showed similar results between groups in AHI, sleepiness score, and quality of life.21,22 Our work, on one hand, confirmed these findings: we found a significant improvement in AHI, oxygen desaturation index, and total sleep time with SpO2 < 90% in the group titrated at home, without significant differences between the groups. On the other hand, our study is different from the studies mentioned above in 2 important aspects: first, the method of titration. In fact, in the Sériès work,20 all subjects underwent unmonitored titration with automatic CPAP, and there was no laboratory group. The other 2 studies21,22 included attended groups, and the subjects underwent manual titration during PSG. We compared 2 groups, attended versus unattended, both titrated with automatic CPAP. Indeed, our goal was not to evaluate the effectiveness of the device, but rather to test its usefulness outside the hospital. Thus, we thought that the presence of manual titration in the laboratory group could be a confounding factor for analysis. Second, this protocol did not include follow-up of the subjects, because we did not intend to assess patient adherence or adaptation to CPAP.

The required duration of home automatic CPAP monitoring still remains to be determined. Bosi and Fiorentino23 reported that patients experienced good quality sleep after about 10 days of home titration. Bachour et al,24 who evaluated cost-effectiveness, found that the optimal trial duration is 5 days. In a large multicenter study, Masa et al21 showed the achievement of automatic titration at home after 1–3 nights. Our protocol consisted of 4-day unmonitored automatic CPAP titration. Similar to other works,24,25 between home titration nights we found no significant differences in the therapeutic pressure values. This result led us to consider the last 3 nights unnecessary. However, it is important to underline that not all subjects achieved normalized AHI. In this regard we would like to highlight the important role of the attended in-laboratory PSG with fixed CPAP, performed after a 4-night home titration, to confirm the therapeutic pressure values. In 2007 the American Academy of Sleep Medicine declared that a home-based protocol could be used without any further confirmation.18 Nevertheless, there is evidence that, by repeating manual titration for more nights in the laboratory, we can obtain different values, by 1, 2, and sometimes 3 cm H2O.26 Moreover, recently Mulgrew et al27 found an AHI of > 10 events/h in 25% of manually titrated subjects, when examined over the time. Both these results and our work suggest that an attended confirming PSG could be a valid method to correct pressure values when it is needed.

The reliability of the home-based protocol is also demonstrated by the absence of significant differences between the groups in the percentage of subjects who dropped out of the study. Indeed, the numbers of both poor quality recordings and early refusal of CPAP were similar between the 2 groups. The literature has reported a wide variability in percentage of patients who refuse CPAP before/during home titration.24,25,28 In our work, 17% refused CPAP in the home group, versus 14% in the laboratory group.

An important limitation of this study is that we enrolled subjects with high risk for moderate to severe OSA. Thus, our results apply only to this patient population. On the other hand, we followed the recommendations, mentioned above, provided by the American Academy of Sleep Medicine.18 Additional studies are required to measure the effects of home automatic CPAP titration on outcomes such as sleepiness and quality of life.

Conclusions

In conclusion, the home diagnosis and titration approach should be considered in a subset of patients with OSA. A single unattended titration night is sufficient to determine the therapeutic pressure. In subjects titrated both in the home and the laboratory setting, a confirming PSG may be useful.

Footnotes

  • Correspondence: Pierluigi Carratù MD PhD, Institute of Respiratory Disease, University of Bari, Piazza Giulio Cesare 11, Bari, Italy 70124. E-mail: pierluigicarratu{at}yahoo.com.
  • The authors have disclosed no conflicts of interest.

  • Copyright © 2013 by Daedalus Enterprises

References

  1. 1.↵
    1. Douglas NJ,
    2. Thomas S,
    3. Jan MA
    . Clinical value of polysomnography. Lancet 1992;339(8789):347-350.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Morgenthaler TI,
    2. Aurora RN,
    3. Brown T,
    4. Zak R,
    5. Alessi C,
    6. Boehlecke B,
    7. et al
    . Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report. Sleep 2008;31(1):141-147.
    OpenUrlPubMed
  3. 3.↵
    1. Young T,
    2. Palta M,
    3. Dempsey J,
    4. Skatrud J,
    5. Weber S,
    6. Badr S
    . The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med 1993;328(17):1230-1235.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Young T,
    2. Peppard PE,
    3. Taheri S
    . Excess weight and sleep-disordered breathing. J Appl Physiol 2005;99(4):1592-1599.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Kales A,
    2. Bixler EO,
    3. Cadieux RJ,
    4. Schneck DW,
    5. Shaw LC 3rd.,
    6. Locke TW,
    7. et al
    . Sleep apnoea in a hypertensive population. Lancet 1984;2(8410):1005-1008.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Peppard PE,
    2. Young T,
    3. Palta M,
    4. Skatrud J
    . Prospective study of the association between sleep-disordered breathing and hypertension. N Engl J Med 2000;342(19):1378-1384.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Malone S,
    2. Liu PP,
    3. Holloway R,
    4. Rutherford R,
    5. Xie A,
    6. Bradley TD
    . Obstructive sleep apnoea in patients with dilated cardiomyopathy: effects of continuous positive airway pressure. Lancet 1991;338(8781):1480-1484.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Partinen M,
    2. Palomäki H
    . Snoring and cerebral infarction. Lancet 1985;2(8468):1325-1326.
    OpenUrlPubMed
  9. 9.↵
    1. Yaggi HK,
    2. Concato J,
    3. Kernan WN,
    4. Lichtman JH,
    5. Brass LM,
    6. Mohsenin V
    . Obstructive sleep apnea as a risk factor for stroke and death. N Engl J Med 2005;353(19):2034-2041.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. George CF
    . Reduction in motor vehicle collisions following treatment of sleep apnoea with nasal CPAP. Thorax 2001;56(7):508-512.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. Flemons WW,
    2. Douglas NJ,
    3. Kuna ST,
    4. Rodenstein DO,
    5. Wheatley J
    . Access to diagnosis and treatment of patients with suspected sleep apnea. Am J Respir Crit Care Med 2004;169(6):668-672.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Parra O,
    2. García-Esclasans N,
    3. Montserrat JM,
    4. García Eroles L,
    5. Ruíz J,
    6. López JA,
    7. et al
    . Should patients with sleep apnoea/hypopnoea syndrome be diagnosed and managed on the basis of home sleep studies? Eur Respir J 1997;10(8):1720-1724.
    OpenUrlAbstract
  13. 13.↵
    1. Mulgrew AT,
    2. Fox N,
    3. Ayas NT,
    4. Ryan CF
    . Diagnosis and initial management of obstructive sleep apnea without polysomnography: a randomized validation study. Ann Intern Med 2007;146(3):157-166.
    OpenUrlPubMed
  14. 14.↵
    1. Epstein LJ,
    2. Kristo D,
    3. Strollo PJ Jr.,
    4. Friedman N,
    5. Malhotra A,
    6. Patil SP,
    7. et al
    ; on behalf of Adult Obstructive Sleep Apnea Task Force of the American Academy of Sleep Medicine. Clinical guideline for the evaluation, management and long-term care of obstructive sleep apnea in adults. J Clin Sleep Med 2009;5(3):263-276.
    OpenUrlPubMed
  15. 15.↵
    Gruppo di studio sui disturbi respiratori nel sonno dell'Associazione Italiana Pneumologi Ospedalieri. Linee guida per la refertazione della polisonnografia e dei monitoraggi cardiorespiratori per sospetta sindrome della apnee ostruttive nel sonno in soggetti adulti. Rassegna di Patologia dell'Apparato Respiratorio 2003;18:305-308. Article in Italian.
    OpenUrl
  16. 16.↵
    1. Chiner E,
    2. Signes-Costa J,
    3. Arriero JM,
    4. Marco J,
    5. Fuentes I,
    6. Sergado A
    . Nocturnal oximetry for the diagnosis of the sleep apnoea hypopnoea syndrome: a method to reduce the number of polysomnographies? Thorax 1999;54(11):968-971.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Lloberes P,
    2. Sampol G,
    3. Levy G,
    4. Aristizabal D,
    5. Sagales T,
    6. De la Calzada M,
    7. et al
    . Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnoea syndrome. Eur Respir J 2001;18(3):530-534.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Collop NA,
    2. Anderson WM,
    3. Boehlecke B,
    4. Claman D,
    5. Goldberg R,
    6. Gottlieb DJ,
    7. et al
    ; on behalf of Portable Monitoring Task Force of the American Academy of Sleep Medicine. Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. J Clin Sleep Med 2007;3(7):737-747.
    OpenUrlPubMed
  19. 19.↵
    1. Flemons WW,
    2. Littner MR,
    3. Rowley JA,
    4. Gay P,
    5. Anderson WM,
    6. Hudgel DW,
    7. et al
    . Home diagnosis of sleep apnea: a systematic review of the literature. An evidence review cosponsored by the American Academy of Sleep Medicine, the American College of Chest Physicians, and the American Thoracic Society. Chest 2003;124(4):1543-1579.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Sériès F
    . Accuracy of an unattended home CPAP titration in the treatment of obstructive sleep apnea. Am J Respir Crit Care Med 2000;162(1):94-97.
    OpenUrlPubMed
  21. 21.↵
    1. Masa JF,
    2. Jiménez A,
    3. Durán J,
    4. Capote F,
    5. Monasterio C,
    6. Mayos M,
    7. et al
    . Alternative methods of titrating continuous positive airway pressure: a large multicenter study. Am J Respir Crit Care Med 2004;170(11):1218-1224.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Skomro RP,
    2. Gjevre J,
    3. Reid J,
    4. McNab B,
    5. Ghosh S,
    6. Stiles M,
    7. et al
    . Outcomes of home-based diagnosis and treatment of obstructive sleep apnea. Chest 2010;138(2):257-263.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Bosi M,
    2. Fiorentino F
    . Validità della titolazione con autoCPAP e con monitoraggio cardiorespiratorio per il trattamento della sindrome delle apnee ostruttive nel sonno. Rassegna di Patologia dell'Apparato Respiratorio 2007;22:381-390. Article in Italian.
    OpenUrl
  24. 24.↵
    1. Bachour A,
    2. Virkkala JT,
    3. Maasilta PK
    . AutoCPAP initiation at home: optimal trial duration and cost-effectiveness. Sleep Med 2007;8(7-8):704-710.
    OpenUrlPubMed
  25. 25.↵
    1. Sériès F,
    2. Plante J,
    3. Lacasse Y
    . Reliability of home CPAP titration with different automatic CPAP devices. Respir Res 2008;9:56.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Wiest GH,
    2. Fuchs FS,
    3. Harsch IA,
    4. Pour Schahin S,
    5. Lampert S,
    6. Brueckl WM,
    7. et al
    . Reproducibility of a standardized titration procedure for the initiation of continuous positive airway pressure therapy in patients with obstructive sleep apnoea. Respiration 2001;68(2):145-150.
    OpenUrlPubMed
  27. 27.↵
    1. Mulgrew AT,
    2. Lawati NA,
    3. Ayas NT,
    4. Fox N,
    5. Hamilton P,
    6. Cortes L,
    7. Ryan CF
    . Residual sleep apnea on polysomnography after 3 months of CPAP therapy: clinical implications, predictors and patterns. Sleep Med 2010;11(2):119-125.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Cross MD,
    2. Vennelle M,
    3. Engleman HM,
    4. White S,
    5. Mackay TW,
    6. Twaddle S,
    7. Douglas NJ
    . Comparison of CPAP titration at home or the sleep laboratory in the sleep apnea hypopnea syndrome. Sleep 2006;29(11):1451-1455.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

Respiratory Care: 58 (7)
Respiratory Care
Vol. 58, Issue 7
1 Jul 2013
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
  • Monthly Podcast

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Home Unattended Portable Monitoring and Automatic CPAP Titration in Patients with High Risk for Moderate to Severe Obstructive Sleep Apnea
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Home Unattended Portable Monitoring and Automatic CPAP Titration in Patients with High Risk for Moderate to Severe Obstructive Sleep Apnea
Ersilia Tedeschi, Pierluigi Carratù, Mario Francesco Damiani, Valentina Anna Ventura, Riccardo Drigo, Edda Enzo, Alberto Ferraresso, Geo Sasso, Franco Maria Zambotto, Onofrio Resta
Respiratory Care Jul 2013, 58 (7) 1178-1183; DOI: 10.4187/respcare.01939

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Home Unattended Portable Monitoring and Automatic CPAP Titration in Patients with High Risk for Moderate to Severe Obstructive Sleep Apnea
Ersilia Tedeschi, Pierluigi Carratù, Mario Francesco Damiani, Valentina Anna Ventura, Riccardo Drigo, Edda Enzo, Alberto Ferraresso, Geo Sasso, Franco Maria Zambotto, Onofrio Resta
Respiratory Care Jul 2013, 58 (7) 1178-1183; DOI: 10.4187/respcare.01939
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Methods
    • Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • obstructive sleep apnea
  • OSA
  • CPAP
  • automatic CPAP titration
  • home titration
  • portable monitoring

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire