Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
LetterCorrespondence

Double Lumen Endotracheal Tube for Percutaneous Tracheostomy?

Fausto Ferraro, Pierluigi Fusco, Lucia Marullo and Annarita Torino
Respiratory Care March 2015, 60 (3) e62; DOI: https://doi.org/10.4187/respcare.03911
Fausto Ferraro
Department of Anesthesiological, Surgical and Emergency Sciences Second University of Naples Naples, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pierluigi Fusco
Department of Anesthesiological, Surgical and Emergency Sciences Second University of Naples Naples, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lucia Marullo
Department of Anesthesiological, Surgical and Emergency Sciences Second University of Naples Naples, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Annarita Torino
Department of Anesthesiological, Surgical and Emergency Sciences Second University of Naples Naples, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

To the Editor:

We read with great interest the article by Vargas et al1 on their in vitro study of the flow resistance of a double lumen endotracheal tube (DLET) suggested as an alternative to a standard orotracheal tube for ventilation during percutaneous tracheostomy. However, we feel some aspects deserve further comments. They made a comparison of flow resistance among the different standard-size endotracheal tubes and the DLET during fiberoptic bronchoscope insertion, remarking upon the presence of a well known increased flow resistance when the fiberoptic bronchoscope is inserted in standard devices. Although the authors carried out extensive work on the physical properties of the DLET in vitro, as we can clearly read in the abstract and text, the title refers to an in vivo clinical procedure. Moreover, even if they show relevant data, they extend their conclusions to clinical practice. The final judgment on the use of the device in vivo, based only on the in vitro experimental study, does not reflect the study's data.

Other comments based on our clinical experience are then necessary. The first, which concerns in vivo experimentation, is about tube positioning. We agree that the tube can be safely positioned with a tube exchanger (airway exchange catheter [AEC]), but a small one (outer diameter) is needed due to the distal DLET's elliptic shape (Fig. 1). For the same reason, DLET slippage on the AEC can result in further difficulties: when the DLET is inserted with the AEC, the elliptic shape defines 2 semilunar lateral areas exceeding the AEC profile (Fig. 1, blue areas). These areas could impact anatomical structures with glottic damage and bleeding if the DLET is positioned with only the AEC.

Fig. 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.

Airway exchange catheter (AEC) in the distal elliptic section of a double lumen endotracheal tube.

In our clinical practice, we use a small diameter tube (5-mm inner diameter) that can be safely positioned with the AEC without laryngoscopy, as we have described previously.2,3 We know that the resistances in the smaller diameter tube are increased, but they affect only the mechanical ventilator in the inspiratory phase. In the expiratory phase, the flow follows the physiological path because the tube is uncuffed. This system offers the greatest vision of the operatory field without any interference with ventilation or surgery during the entire procedure.

Footnotes

  • The authors have disclosed no conflicts of interest.

  • Copyright © 2015 by Daedalus Enterprises

References

  1. 1.↵
    1. Vargas M,
    2. Servillo G,
    3. Tessitore G,
    4. Aloj F,
    5. Brunetti I,
    6. Arditi E,
    7. et al
    . Double lumen endotracheal tube for percutaneous tracheostomy. Respir Care 2014;59(11):1652–1659.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Ferraro F,
    2. Capasso A,
    3. Troise E,
    4. Lanza S,
    5. Azan G,
    6. Rispoli F,
    7. Anello CB
    . Assessment of ventilation during the performance of elective endoscopic-guided percutaneous tracheostomy: clinical evaluation of a new method. Chest 2004;126(1):159–164.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Ferraro F,
    2. Marfella R,
    3. Petruzzi J,
    4. Torino A,
    5. d'Elia A,
    6. Lettieri B
    . Translaryngeal open ventilation for percutaneous endoscopic tracheostomy. Br J Anaesth 2014;113(1):189–190.
    OpenUrlFREE Full Text
PreviousNext
Back to top

In this issue

Respiratory Care: 60 (3)
Respiratory Care
Vol. 60, Issue 3
1 Mar 2015
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
  • Monthly Podcast

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Double Lumen Endotracheal Tube for Percutaneous Tracheostomy?
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Double Lumen Endotracheal Tube for Percutaneous Tracheostomy?
Fausto Ferraro, Pierluigi Fusco, Lucia Marullo, Annarita Torino
Respiratory Care Mar 2015, 60 (3) e62; DOI: 10.4187/respcare.03911

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Double Lumen Endotracheal Tube for Percutaneous Tracheostomy?
Fausto Ferraro, Pierluigi Fusco, Lucia Marullo, Annarita Torino
Respiratory Care Mar 2015, 60 (3) e62; DOI: 10.4187/respcare.03911
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire