Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
EditorialEditorials

The Ongoing Question of Where Clinicians Should Place the Nebulizer in the Ventilator Circuit: This Time With Epoprostenol

John D Davies
Respiratory Care November 2017, 62 (11) 1504; DOI: https://doi.org/10.4187/respcare.05884
John D Davies
Respiratory Care Services Duke Health System Durham, North Carolina
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
  • Article
  • References
  • Info & Metrics
  • PDF
Loading

In this issue of Respiratory Care, Anderson and colleagues1 determined the differences in epoprostenol deposition based on nebulizer position in the ventilator circuit in an adult lung model using vibrating mesh technology. The study involved placing the nebulizer at 4 different positions in the ventilator circuit (humidifier inlet, humidifier outlet, within the inspiratory limb, and between the endotracheal tube and the Y-piece) and collecting the aerosolized epoprostenol on a filter located at the distal end of the endotracheal tube. With this particular model, the authors found that the highest delivery of epoprostenol occurred when the nebulizer was situated at the humidifier inlet, with the humidifier outlet position being a close second.

I commend the efforts of the authors in their attempt to determine the optimal nebulizer position for epoprostenol delivery. A study such as this is especially important because the use of epoprostenol is very attractive from a financial perspective compared to the use of inhaled nitric oxide. In addition, although this has not been documented, I strongly suspect that the use of epoprostenol in place of inhaled nitric oxide is increasing among institutions in the United States. To that end, it is important to determine best methods to optimize deposition.

The study by Anderson et al, however, does not provide us with a definitive answer as to where to place the nebulizer in the ventilator circuit. In their model, filters were used to collect the epoprostenol, which means that we know the amount of epoprostenol that was delivered to the filter, but we do not the particle size being delivered. We have no way of knowing whether any or all of the drug delivered to the filters would have made it past the larger conducting airways. Second, the same controller was used at each specific site. What appears to be unknown is whether there were any inherent functional differences between the 4 controller units that could potentially explain some of the results. The functional decay of the mesh in the nebulizers is also unknown. Some more viscous medications have the potential to eventually clog the mesh and cause the nebulizer to fail. Fortunately, the researchers didn't experience the same level of nebulizer failure rate as Gowda and colleagues.2 In the Gowda study, a 25% to 30% failure rate of the nebulizer was reported when nebulizing sterile and distilled water.

While concerns remain with regard to the reliability of the nebulizers and controller units, the work by Anderson and colleagues mirrors that of Ari et al3 and Berlinski and Willis,4 suggesting that optimal placement of the nebulizer is pre-humidifier. This study represents an encouraging step in the right direction for future use of aerosolized epoprostenol as an alternative to inhaled nitric oxide. More research is needed in the area of in vivo drug deposition to further understand the various factors associated with optimal drug delivery.

Footnotes

  • Correspondence: Duke University Health System, Box 3911, DUH, Durham, North Carolina 27710. E-mail: john.davies{at}duke.edu.
  • Mr Davies discloses relationships with Resmed and Bayer.

  • See the Original Study on Page 1387

  • Copyright © 2017 by Daedalus Enterprises

References

  1. 1.↵
    1. Anderson AC,
    2. Dubinsky MN,
    3. Fiorina KA,
    4. Quintana V,
    5. Kaplan CA,
    6. Vines DL
    . The effect of nebulizer position on aerosolized epoprostenol delivery in an adult lung model. Respir Care 2017; Jul 18. pii: respcare.05344. doi: 10.4187/respcare.05344. [Epub ahead of print]
  2. 2.↵
    1. Gowda AA,
    2. Cuccia AD,
    3. Smaldone GC
    . Reliability of vibrating mesh technology. Respir Care 2017;62(1):65–69.
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    1. Ari A,
    2. Atalay OT,
    3. Harwood R,
    4. Sheard MM,
    5. Aljamhan EA,
    6. Fink JB
    . Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation. Respir Care 2010;55(7):845–851.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Berlinski A,
    2. Willis RJ
    . Albuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model. Respir Care 2013;58(7):1124–1133.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Respiratory Care: 62 (11)
Respiratory Care
Vol. 62, Issue 11
1 Nov 2017
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Ongoing Question of Where Clinicians Should Place the Nebulizer in the Ventilator Circuit: This Time With Epoprostenol
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
The Ongoing Question of Where Clinicians Should Place the Nebulizer in the Ventilator Circuit: This Time With Epoprostenol
John D Davies
Respiratory Care Nov 2017, 62 (11) 1504; DOI: 10.4187/respcare.05884

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
The Ongoing Question of Where Clinicians Should Place the Nebulizer in the Ventilator Circuit: This Time With Epoprostenol
John D Davies
Respiratory Care Nov 2017, 62 (11) 1504; DOI: 10.4187/respcare.05884
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Footnotes
    • References
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire