Abstract
BACKGROUND: Exercise training is an effective and low-cost tool for COPD rehabilitation. Thus, validating a non-exhaustive method to determine a patient's anaerobic threshold would be a very interesting tool in practical settings. We aimed to test the reproducibility of critical velocity values determined in a non-exhaustive manner (CVNE) and tolerance for exercise performed at this physiological marker in subjects with COPD.
METHODS: Twelve subjects with COPD were evaluated in this cross-sectional study. The study was divided into 2 phases: Phase A consisted of reproducibility of CVNE for subjects with COPD, and Phase B determined the tolerance for exercise tests performed at this physiological marker.
RESULTS: The proposed protocol for determining CVNE presented fair reproducibility according to blood lactate concentrations (intraclass correlation coefficient = 0.58). However, we cannot consider that the tests were reproducible due to the wide CI (0.03–0.85). Furthermore, moderate and strong correlations were observed between the CVNE determined by lactate concentration, by oxygen consumption (V̇O2) (r = 0.66), and by heart rate (r = 0.88). However, a high limit of agreement was observed ±1.45 km/h and ±1.55 km/h, respectively. In the tolerance for exercise test, none of the subjects presented lactate destabilization, whereas 3 tests were interrupted by oxygen saturation decline and 1 test was interrupted by hemodynamic instability.
CONCLUSIONS: Although most of the subjects presented good tolerance for exercise at CVNE, fair levels of reproducibility were observed in subjects with COPD, even using lactate. Thus, the use of CVNE determined through double 3-min efforts should be considered with caution
Introduction
COPD is known not only for its pulmonary effects but also for systemic manifestations (eg, muscle weakness, inflammation).1 Several studies have demonstrated that exercise training is an effective and low-cost tool during COPD rehabilitation, improving muscular strength, exercise tolerance, and quality of life.2
The prescription of exercise intensity for this population should be individualized instead of adopting general parameters, such as intensity calculations according to heart rate3,4 or fatigue scale.5 In this context, the prescription of exercise through maximum tests such as the cardiopulmonary exercise test6,7 is common in clinical practice.4,8 Two aerobic parameters can be determined using these methods: the maximal intensity achieved, which is frequently concomitant with maximal oxygen consumption, and the anaerobic threshold.9 Although several studies prescribe exercise training using the maximal intensity achieved, the anaerobic threshold is an important physiological index that demarcates the intensity at which systemic acidosis increases.10 However, determination of this physiological marker is limited in patients with COPD mainly by the exhaustive characteristics of the cardiopulmonary exercise, in which dyspnea and hemodynamic alterations can be observed.11 Gas exchange should be also monitored during the effort, increasing the cost of evaluation and discomfort of patients who are required to wear a mask.6
For these reasons, a non-exhaustive method to determinate the anaerobic threshold would be a very interesting tool in practical settings. In this context, Chassain12 determined the anaerobic threshold using several double non-exhaustive efforts. The protocol establishes that the participant needs to perform 2 submaximal efforts, at the same intensity, with 90 s of passive recovery between them. Blood lactate concentrations (Lac) are determined after each effort, and the difference between them is calculated (ΔLac). This procedure is repeated 3–4 times using different intensities, and the anaerobic threshold is calculated as the intensity that presents a balance between the efforts (ie, ΔLac = 0), which is determined using simple linear regression. The use of the mathematical procedure has led some authors to call the anaerobic threshold determined by Chassain as critical velocity determined in a non-exhaustive manner (CVNE).13–15
Therefore, the use of Chassain's procedure is a practical tool to determine CVNE, mainly through the use of non-exhaustive efforts. Considering that CVNE is theoretically the intensity of physiological balance, it is possible that other parameters can be used for its determination without blood samples, such as heart rate or oxygen consumption (V̇O2). However, no studies have tested the reproducibility or tolerance for exercise performed at CVNE, which does not allow its use in monitoring and prescribing exercise training for patients with COPD. Thus, we aimed to test the reproducibility of CVNE and the tolerance for exercise performed at this physiological marker in subjects with COPD.
QUICK LOOK
Current knowledge
Appropriate exercise prescription for patients with COPD enhances the results of the intervention. Prescription of exercise intensity should be individualized instead of adopting general parameters, such as calculations through heart rate or fatigue scale. Exercise prescription using maximum tests is common in clinical practice. However, this method is limited in patients with COPD, mainly because of its exhaustive characteristics, in which dyspnea and hemodynamic alterations can be observed.
What this paper contributes to our knowledge
The proposed protocol to determine critical velocity determined in a non-exhaustive manner presented fair reproducibility in subjects with COPD, and most subjects presented good tolerance for exercise at maximum intensity. This protocol may be a new tool for exercise prescription, saving the patient from performing at maximum physical exertion.
Methods
Subjects
For this study, 12 subjects with COPD from a physical therapy clinic of São Paulo State University in Brazil were evaluated. To participate in the study, the inclusion criteria were to have the results of spirometry tests and medical diagnosis of the disease as recommended by the Global Initiative for Obstructive Lung Disease (GOLD).16 Exclusion criteria were current smoking, use of home oxygen therapy, presence of comorbidities or musculoskeletal disorders that prevented execution of the experimental protocol, and unstable COPD (ie, exacerbations and medication changes in the previous 30 d). All procedures were approved by the ethics committee of the institution (CAAE: 01114912.0.0000.5402), and all subjects signed a consent form.
Study Design
This cross-sectional study was performed over 10 days. The study was divided into 2 phases (Fig. 1). In Phase A, the reproducibility of CVNE was tested; during Phase B, the tolerance for exercise performed at CVNE was assessed. The first day involved subject identification, anthropometric measurements, spirometry, and the 6-min walk test (6MWT). On the other days, the subjects were randomly assigned to 3 exercise sessions with an intensity of 70%, 90%, and 110% of the mean speed achieved in the 6MWT.13 In each session, double efforts were performed at the same intensity, with a duration of 180 s each, separated by an interval of 90 s. Subsequently, the subjects repeated the 3 speeds, also in random order, to assess the reproducibility of the CVNE values. The tests were performed at intervals of at least 24 h.
Finally, 3 d of assessment were performed for exercise tolerance at CVNE. Phase B was carried out to simulate a training prescription held at the CVNE intensity. Subjects performed a session of exercise at speeds of 100%, 110%, and 120% of the CVNE obtained in the first test performed during phase A. The sessions were conducted on 3 different days, at least 24 h apart. The subjects maintained normal administration of bronchodilators during evaluation days. Because the subjects normally used this medication, it is understood that their usual daily condition was evaluated.
Subjects were instructed to eat a light meal 2 h before testing, to avoid strenuous exercise the day before the evaluations, to avoid caffeine for 12 h before the test, and to wear appropriate and comfortable clothing for the exercise.
Anthropometric Evaluation, Pulmonary Function Assessment, and 6MWT
Body mass was measured on a digital scale (R/I 200, Welmy, Brazil). Height was measured using a stadiometer (Sanny, Brazil). Anthropometric measurements were obtained according to Lohman et al.17 Body mass index was also calculated.
Pulmonary function was assessed according to spirometry tests, using an MIR-Spirobank 3.6 version spirometer (MIR, Italy). Interpretations of the results were performed according to the American Thoracic Society and European Respiratory Society guidelines.18 Normality values were related to the Brazilian population.19
The functional exercise capacity was assessed with the 6MWT according to the guidelines of the American Thoracic Society.20 The experimental values obtained were analyzed according to values provided by Enright and Sherrill.21
Phase A: Chassain Protocol
Participants performed 3 sessions of exercise at 70%, 90%, and 110% of the average speed achieved in 6MWT. In each session, double efforts were performed at the same intensity, with duration of 180 s each, separated by a passive interval of 90 s. All tests were performed on a treadmill (ATL Inbramed, Inbrasport, Porto Alegre, Brazil). Heart rate was monitored continuously (Polar Electro, S810i, Finland), and oxygen consumption, carbon dioxide production, and ventilation were measured (VO2000, MGC Diagnostics, Saint Paul, Minnesota).
Blood samples (25 μL) were collected from the earlobe, at rest and after each effort, to determine lactate concentration and examined with a sport lactate analyzer (YSI 1500, YSI, Yellow Springs, Ohio). Peripheral oxygen saturation (SpO2) was verified with pulse oximetry (PM100C, NewTech, China) and subjective perception of dyspnea and fatigue was assessed using the Borg scale.22
The mean heart rate, oxygen consumption (V̇O2) observed in the final 30 s, and Lac were determined at the end of each effort. The difference between the second and first efforts determined the Δ lactate, Δ heart rate, and Δ V̇O2.
A linear adjustment was performed between (lactate, heart rate, and V̇O2; x axis) and the exercise intensity (70%, 90%, and 110% of 6MWT; y axis). Thus, the CVNE was assumed as the y-intercept of this adjustment.12
Example: Effort at 70% of 6MWT: Δ lactate = −0.48 mM; speed = 4.1 km/h.
Effort at 90% of 6MWT: Δ lactate = 0.26 mM; speed = 5.2 km/h.
Effort at 110% of 6MWT: Δ lactate = 0.93 mM; speed = 6.4 km/h.
Thus, x axis was composed of Δ lactate values, and the y axis was composed of speed values. Adjusting this relationship using a linear regression procedure, the following equation was obtained:
Speed = (1.6287 × Δ lactate) + 4.8479
Considering that the linear coefficient is the value corresponding to the lactate stabilization (ie, Δ lactate = 0), the CVNE was assumed for this subject to be 4.8479 km/h.
Phase B: Tolerance for Exercise Test
The exercise tolerance test was carried out to simulate a training prescription held at the CVNE intensity. These sessions were conducted to observe the kinetics of lactate concentration, that is, to observe whether subjects would present lactate destabilization during the progression of the sessions.
The participants performed 3 constant efforts on a treadmill, each lasting 30 min, simulating a training session. The intensities of the effort were 100%, 110%, and 120% of the CVNE conducted on 3 different days, at least 24 hours apart.
The lactate, heart rate, SpO2, Borg fatigue, and Borg dyspnea were determined at rest, after 10 min, and after 30 min.
Statistical Treatment
The normality of the data were confirmed with the Shapiro-Wilk test. The comparison of the means of CVNE between the test and retest was analyzed with the dependent t test. The intraclass correlation coefficient, the coefficient of variation, and typical error23 were verified using lactate, V̇O2, and heart rate in the test and retest. The intraclass correlation coefficients were defined as <0.40 = poor; 0.40–0.60 = fair; 0.60–0.74 = good; and >0.75 = strong.24 The effect size classes were defined according to calculated d values: small (d ≤ 0.2), moderate (d = 0.5), or large (d ≥ 0.8)].25 Comparisons between CVNE in the test determined through the lactate concentration, V̇O2, and heart rate were tested with 1-way analysis of variation.
Correlations were performed between the CVNE determined with lactate, with V̇O2, and with heart rate with the Spearman test. Agreement between CVNE in the test determined through the lactate, V̇O2, and the heart rate was tested with the Bland-Altman plot.26 The statistical program used was SPSS version 15.0.
Results
Phase A: Chassain Protocol
Twelve subjects with COPD were included in this study. The anthropometric, functional, and initial spirometric data from the subjects are presented in Table 1.
Table 2 shows the values obtained by linear regression to determine CVNE. No differences were observed between test and retest in lactate (P = .89) or heart rate (P = .74), whereas significant differences were observed in V̇O2 (P = .02). Fair intraclass correlation coefficient values were observed for determination of CVNE using lactate (intraclass correlation coefficient = 0.58). However, we cannot consider that the tests were reproducible due to the wide CI (0.03–0.85). Additionally, poor agreement was observed using heart rate. Moderate typical error values were detected in CVNE for all variables. No differences were observed when comparing CVNE determined by lactate, V̇O2, and heart rate (P = .34).
During the efforts at 110% (in Chassain's procedures), 2 subjects required oxygen supplementation during the test, and 2 subjects required oxygen supplementation during the retest. Furthermore, significant correlations were observed between CVNE determined by lactate, CVNE determined by V̇O2 (r = 0.66, P = .01), mean error = −0.54, limits of agreement ± 1.45 km/h (Fig. 2A); and heart rate (r = 0.88, P < .001), mean error = 0.09, limits of agreement ± 1.55 km/h (Fig. 2B).
Phase B: Tolerance for Exercise Test
In the tolerance for exercise test, none of the subjects displayed lactate destabilization (difference of 1 mM in lactate concentration), as there was no difference in the variables of heart rate (P = .54), SpO2 (P = .23), Borg dyspnea (P = .65), and Borg fatigue (P = .94) at different intensities (100%, 110%, and 120% of CVNE). However, 3 tests were interrupted by a decline of oxygen saturation, and 1 test was interrupted by hemodynamic instability at 120% (Fig. 3).
Discussion
The main findings of this study demonstrated that the protocol proposed by Chassain12 for determining CVNE presented fair reproducibility through lactate in subjects with COPD. Despite moderate correlations between the CVNE determined by lactate or the CVNE determined by V̇O2 and heart rate, substituting the lactate for these variables is not recommended due to the high limit of agreement observed. In the exercise tolerance testing, no subjects presented lactate destabilization; however, 3 tests were interrupted by a decline of oxygen saturation, and 1 test was interrupted by hemodynamic instability.
Phase A: Chassain Protocol
Despite the fact that comparison of CVNE values between test and retest according to lactate and heart rate demonstrated fair reproducibility with small values of effect size in subjects with COPD, we cannot consider that the tests were reproducible due to the large CI. Also, differences were observed between test and retest in the values of critical velocity determined by V̇O2.
While lactate is considered a standard method to determine CVNE, it is an invasive method. Thus, reproducibility, correlation, and agreement analysis between lactate, heart rate, and V̇O2 are important because they are noninvasive variables. One possible explanation for why V̇O2 was not reproducible may be due to the relationship between ventilation and the relative intensity to determine parameters related to aerobic capacity, which is a method often used to establish the metabolic thresholds in healthy individuals.27 However, the observed changes in the ventilation values during incremental exercise may result in ventilatory inefficiency in individuals with COPD.28 This fact could compromise the relationship between ventilation and intensity to determine metabolic thresholds.
Considering that Lac is a standard method to determine critical velocity, the correlation and agreement analysis of lactate with heart rate and V̇O2 were not satisfactory. Despite the moderate correlation with V̇O2 (r = 0.66) and a high correlation with heart rate (r = 0.88), these results should be interpreted with caution. The high agreement limit of heart rate (±1.55 km/h) and V̇O2 (±1.45 km/h) make it unfeasible to substitute lactate for these variables.
Phase B: Exercise Tolerance Testing
We analyzed exercise tolerance testing at 100%, 110%, and 120% of the critical velocity, and we observed that even at intensities of 120%, only 4 subjects (33%) had to stop the test due to hemodynamic instability or decline of oxygen saturation, while there was no destabilization in the lactate. Regarding these findings, lactate may not be a good intensity marker for this population because concentrations at rest were very high, which may explain the negative change values. de Souza GF et al29 showed lactate values at rest are > 2 mM in subjects with COPD. The reason for this wide variation in lactate might be due to hypoxemia and low blood flow to the muscles, leading to abnormalities in the oxidative capacity of the skeletal muscles.30,31
Another possible explanation for non-destabilization of lactate may be due to the duration of effort during tests. As established by previous studies,12,13 we used 2 efforts of 180 s separated by an interval of 90 s. However, other authors have suggested longer efforts to determine aerobic capacity by lactate (eg, 360 s).32 Thus, the lower duration of effort used in this study may have underestimated the intensity of the exercise tolerance testing. Furthermore, when the effort is performed in the moderate physiological domain, the lactate reaches a steady state at 120–180s, and at the heavy physiological domain, the lactate is stable after 300–600s,33 and in a severe physiological domain, the lactate increases until the exercise is interrupted without stabilization.33
Rossi et al13 conducted a study with postmenopausal women in which the participants performed 2 efforts at the same intensity (4, 5, or 6 km/h). The authors recommended sessions with individual intensities prescribed according to physical fitness. Thus, the mechanical inefficiency at lower intensities might modify the behavior of lactate and heart rate and compromise Δ values, consequently compromising CVNE determination (eg, negative slope). Concerning this issue, the strength of our study is that the intensities were prescribed individually, aiming to prevent factors that could interfere in the lactate destabilization.
The limitations of this study were the small sample size, which did not allow us to stratify participants by disease severity.
This study has clinical relevance because the proposed method may be a new tool for exercise prescription for patients with COPD. However, we emphasize the need for adaptations concerning the design of the study, especially if the intention is to use it to prescribe aerobic training in this population. This method can be a promising field of study for future research because it prevents the patient from performing at maximum physical exertion.
Suggestions for future studies include longer duration of stages for the determination of aerobic capacity. Furthermore, the validation should be compared with the gold standard method, that is, the cardiopulmonary exercise test.
In conclusion, although most subjects presented good tolerance for exercise at CVNE, fair levels of reproducibility were observed in subjects with COPD, even using lactate. Thus, the use of CVNE determined through double 3-min efforts should be considered with caution.