Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
  • Log out
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
EditorialEditor's Choice

Evaluating Endotracheal Tube Depth in Infants Weighing Less Than 1 Kilogram

Renee M Bartle, Andrew G Miller, Anthony J Diez, P Brian Smith, Michael A Gentile and Mihai Puia-Dumitrescu
Respiratory Care March 2019, 64 (3) 243-247; DOI: https://doi.org/10.4187/respcare.06202
Renee M Bartle
Respiratory Care Services, Duke University Medical Center, Durham, North Carolina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Andrew G Miller
Respiratory Care Services, Duke University Medical Center, Durham, North Carolina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anthony J Diez
Respiratory Care Services, Duke University Medical Center, Durham, North Carolina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P Brian Smith
Division of Neonatology, Duke University Medical Center, Durham, North Carolina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael A Gentile
Division of Pediatric Critical Care Medicine, Duke University Medical Center, Durham, North Carolina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mihai Puia-Dumitrescu
Division of Neonatology, Duke University Medical Center, Durham, North Carolina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND: Endotracheal tube (ETT) depth in premature infants is of critical importance because potentially life-threatening adverse events can occur if the tube is malpositioned. Analysis of current data indicates that the accuracy of current resuscitation guidelines for infants <1 kg is poor. We hypothesized that a weight-based formula that is used clinically in our institution would accurately predict appropriate ETT placement in infants weighing < 1 kg.

METHODS: The medical records, from July 2013 to November 2016, of all infants < 1 kg who were intubated were retrospectively reviewed and included. The 2 formulas utilized were the Duke formulas 5.5 cm + 1 cm/kg for infants 500–999 g or 5.0 + 1 cm/kg for infants <500 g. The appropriate ETT position was defined as the tip of the ETT below the thoracic inlet and above the carina, at approximately thoracic vertebrae 2 or 3 on an initial chest radiograph. The formula was defined as being accurate if the documented ETT depth was within 0.2 cm of the predicted depth. Post hoc analysis of current resuscitation guidelines (6 cm plus the weight of the infant in kg) was performed after the Duke formula performed worse than expected.

RESULTS: A total of 131 subjects (mean ± gestational age, 26 ± 1.8 wk; mean ± weight, 729 ± 140 g) were included. The documented depth was accurately predicted by the Duke formula for 47% of the subjects, with 69% of the ETTs appropriately positioned as seen on a chest radiograph. Sensitivity was 46.6%, specificity was 53.6%, positive predictive value was 68.8% and negative predictive value was 31.4% for the Duke formula. Post hoc analysis current resuscitation guidelines found that the documented depth was accurately predicted for 23% infants, with 70% of these appropriately positioned ETTs.

CONCLUSIONS: Our weight-based, institutional formula had a low sensitivity for predicting proper ETT depth. Weight-based formulas may have clinical utility; however, analysis of current data did not support use in infants < 1 kg. Rapid radiologic assessment of ETT placement is required for this patient population.

  • endotracheal tube placement
  • neonates
  • premature neonates

Introduction

Premature infants frequently require endotracheal intubation due to cardiopulmonary resuscitation, surfactant deficiency, poor respiratory effort, respiratory distress, or apnea. Appropriate endotracheal tube (ETT) depth is critically important in premature neonates because ETT malpositioning can result in life-threatening adverse events, such as hypoxemia, pneumothorax, or inadvertent extubation. Overzealous manual ventilation at birth may also cause lung injury due to high tidal volumes and high ventilating pressures. Analysis of current data indicates that ETTs are malpositioned in as many as one third of infants1 and in 47% of infants < 1 kg.2

The immature lung is particularly vulnerable at birth due to surfactant deficiency and fluid-filled alveoli, which carries an increased risk of pneumothorax due to low compliance.3 This risk is increased if the ETT is inadvertently inserted into a main bronchus. In addition, proper ETT positioning is critical for the delivery of endogenous surfactant therapy because endobronchial intubation will result in only a single lung receiving surfactant replacement. The Neonatal Resuscitation Program recommendations (American Academy of Pediatrics, Itasca, IL) for initial ETT depth have not been validated in infants < 1 kg. Specifically, the Neonatal Resuscitation Program formula may result in an initial ETT depth that is too deep and may expose neonates to adverse events related to mainstem intubation. In clinical practice, our institution has used a weight-based formula for initial ETT depth for many years that differs from the Neonatal Resuscitation Program formula; however, this formula has not been validated. The purpose of this project was to evaluate the accuracy of this formula.

QUICK LOOK

Current knowledge

Endotracheal tube (ETT) depth in premature infants is of critical importance as potentially life-threatening adverse events can occur if the tube is malpositioned. Analysis of current data indicated that the accuracy of the Neonatal Resuscitation Program formula for infants <1 kg was poor. There is a need for improved formulas for this patient population.

What this paper contributes to our knowledge

A weight-based, institutional formula used clinically had a low sensitivity for predicting proper ETT depth. Weight-based formulas may have clinical utility; however, analysis of current data indicated that their accuracy was poor in infants < 1 kg. Rapid radiologic assessment of ETT placement is necessary.

Methods

After institutional review board approval, we retrospectively identified, through electronic medical records, all infants weighing < 1 kg who required intubation between July 2013 and November 2016. Data were extracted on gestational age in weeks, birthweight, and ETT depth documented in the electronic medical record. Appropriate ETT position on chest radiograph (CXR) after initial intubation was defined as the tip of the ETT below the thoracic inlet and above the carina, at approximately thoracic vertebrae 2 or 3. An ETT above the thoracic inlet was defined as high, and an ETT located below the carina was defined as low. The ETT position on CXR was determined independently by core respiratory therapist (RMB), and neonatology physician (MPD). It is our policy, in the intensive care nursery, to take CXRs with the head in a neutral position. Due to the retrospective nature of this study, we were unable to determine if there was any neck flexion. Unblinded clinicians (RMB, MPD) instead of blinded radiologists were used to reflect actual clinical practice because initial ETT positioning is based on assessment at the bedside in most instances.

In our facility, ETT depth is measured from the lip via direct visualization before ETT taping or via tape measure after the ETT is secured. We were unable to determine which method was used due to the retrospective nature of this study. After determining the documented initial ETT depth, we calculated the predicted ETT depth by using the subject's birthweight and the Duke formula.

Duke Formula

  • Infants between 500 and 999 g: 5.5 cm + 1 cm/kg Duke formulas by using patient's current weight.

  • Infants < 500 g: 5.0 cm + 1 cm/kg Duke formulas by using patient's current weight.

The primary outcome for each version of the formula was the proportion of ETTs appropriately positioned on a CXR. We determined that the Duke formula was met if the predicted ETT depth was within 2 mm of the documented depth. The position on a CXR was classified as good, high, or low. Results for weight, gestational age, and position on a CXR were subsequently compared for the subjects in whom the predicted rule was or was not met. When our rule failed to perform as well as expected, a post hoc analysis of the Neonatal Resuscitation Program formula (6 cm + 1 cm/kg) was performed by using the same methodology as mentioned above.

Data were analyzed by using SPSS software v24 (SPSS, Chicago, Illinois). Chi-square and the unpaired t test were performed for categorical and continuous data, as appropriate. Specificity, sensitivity, and positive and negative predictive values were also calculated. By using only ETTs in the appropriate position on a CXR, we compared the actual mean initial ETT depth with the depth predicted by each formula. Statistical significance was defined as α < 0.05.

Results

A total of 131 subjects met our inclusion criteria. The mean ± SD gestational age was 26 ± 1.8 weeks with a birthweight of 729 ± 140 g. Demographic data are summarized in Table 1. The Duke formula was met for 47% of the infants (61/131). There was no statistical significant difference between the proportion of ETTs appropriately positioned, whether or not the Duke formula was met (69% vs 69%, P = .86). Sensitivity was 46.6%, specificity was 53.6%, the positive predictive value was 68.8%, and the negative predictive value was 31.4% for the Duke formula. Results are summarized in Table 2. In the post hoc analysis of the Neonatal Resuscitation Program formula, the predicted depth formula prediction was met for 23% of the infants (30/131). The results are summarized in Table 3.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1.

Demographics

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 2.

Results for the Duke Formula

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 3.

Results for the Neonatal Resuscitation Program Formula

ETTs were positioned appropriately in 90 infants. When analyzing only those ETTs that were appropriately positioned on the initial CXR, the mean ± SD documented depth was 6.3 ± 0.4 cm (the Duke formula predicted mean ± SD 6.2 ± 0.2 cm vs 6.7 ± 0.1 cm for Neonatal Resuscitation Program formula). The Duke formula prediction provided a closer approximation of the actual ETT depth (47% [42/90]) than the Neonatal Resuscitation Program formula prediction (23% [21/90]). In particular, the Neonatal Resuscitation Program formula would have resulted in the average ETT being placed 0.4 ± 0.1 cm deeper than the actual documented depth.

Discussion

Our study evaluated the ETT depth in 131 premature infants weighing < 1 kg. The Duke formula provided a closer estimate when compared with the Neonatal Resuscitation Program formula rule when only appropriately positioned ETTs were considered; however, overall, neither formula performed well enough to be considered a reliable indicator of ETT depth in infants < 1 kg. We found that the Duke formula prediction was met for 46% of our subjects with no difference in appropriately placed ETTs when the Duke prediction formula was not met. Our results found that the formula was followed in fewer than half of subjects, which indicated that either the formula was not being closely followed in the delivery room or that the ETT depth was being adjusted clinically before the initial CXR. This indicated that our formula was not as closely followed in clinical practice as we believed. Importantly, the Neonatal Resuscitation Program formula prediction seemed to significantly overestimate ETT depth in infants < 1 kg.

Confirmation of proper ETT placement should be completed in all patients at the time of initial intubation. A combination of physical examination methods, fogging in the tube, pulse oximetry, end-tidal carbon dioxide detector, and CXR should be used. These methods only confirm placement in the trachea; currently, radiographic confirmation is needed to evaluate ETT depth. Newer devices are in development to evaluate ETT depth by using acoustic reflectometry but have not, to our knowledge, been used to evaluate neonates.4 Ultrasound imaging may be used to reliably confirm ETT placement but requires specialized equipment, training, and experience in this technique.5 Ultrasound was not in use at our institution during this study. Ideally, a simple formula to determine ETT depth in premature infants would be used; however, there is no formula currently available. Endobronchial intubation and subsequent unilateral surfactant delivery increases infant morbidity and mortality. Pulmonary interstitial emphysema, pneumothorax, and atelectasis can also result from inappropriately placed ETT.3,6,7

The original formula described by Tochen8 is widely known as the 7-8-9 rule for infants 1, 2, and 3 kg, respectively as weight increases, so does the depth of the ETT. This rule is widely used and is included in the Neonatal Resuscitation Program formula guidelines for ETT depth.9 Peterson et al10 found that this rule performed well for infants > 750 g but poorly for those < 750 g. We found that neither the Duke nor Neonatal Resuscitation Program formulas for initial placement performed well for infants < 1 kg, although the Duke formula provided a closer depth when only appropriately placed ETTs were included. There was no significant correlation between subject weight and ETT depth for appropriately placed ETTs, consistent with the results of Kembley et al,11 who found that the appropriate ETT depth was linear with gestational age but logarithmic with weight. Because a 24-wk premature infant has an approximated tracheal length of 26.87 mm (pre-bifurcation and bifurcation length together), the 0.4 cm difference in ETT depth between the Duke formula and the Neonatal Resuscitation Program formula can have deleterious effects.12

Flinn et al13 examined this question in a randomized trial by using either gestational age or birthweight and found no differences in correctly positioned ETTs between the groups. Importantly, this trial found that 51% of ETTs were malpositioned when depth was determined by weight (by using the Neonatal Resuscitation Program formula rule) compared with 39% when gestational age was used.13 Amarilyo et al2 found similar results in 31 infants < 1 kg; however, they adjusted the ETT depth based on auscultation and found, on CXR, that 74% of ETTs were well positioned. ETT placement was significantly deeper in subjects for whom the Duke formula prediction was not met, which indicated that either the rule was not being followed closely in the stressful environment of the delivery room or the ETT was repositioned based on clinical assessment. Peterson et al10 validated the 7–8-9 rule in a cohort of 75 infants and found that this rule performed well for infants > 750 g. For 17 infants < 750 g, the formula was found to be significantly inaccurate, with the ETT positioned between 0.3 and 0.9 cm too deep.10

Sakhuja et al14 performed a survey of clinical practice that revealed that the majority of respondents (87%) used the Neonatal Resuscitation Program formula or inserted the ETT past the black vocal cord marking to estimate ETT depth. Although the results of the study by Kempley et al,11 and supported by our results, indicate that weight-based formulas are inadequate for infants < 1 kg, these studies were relatively small, single-center studies.11 Flinn et al13 directly compared the 2 methods and found neither to be superior; however, this study was underpowered to detect differences in the ETT position because they only enrolled 90 infants in total. A large, multi-center trial is clearly needed to better evaluate which method (weight-based formula or gestational age) is superior.

Leung15 recently investigated ETT depth in infants < 1 kg and found that birthweight, gestational age, and body length were all linearly correlated with the ETT depth. The strongest correlation was with birthweight; however, the R2 value was only 0.497, R2 was 0.458 for body length and R2 gestational age was 0.338. It was found that body weight was a reasonable starting point, body length could be used as an alternative but the most appropriate method to confirm ETT position was with rapid radiographic confirmation.15 Our results confirmed that ETT depth was poorly correlated with birthweight; thus analysis of current data indicated that weight-based formulas were inadequate to evaluate ETT depth in infants < 1 kg.

Our study had several limitations. As a retrospective review, data were limited to data available in the medical record. Measurement of ETT depth at the lip may have varied among respiratory therapists. Use of the formula and the proper head positioning during CXR were unable to be controlled by study personnel. ETT depth may have been adjusted based on clinical grounds before the initial CXR; however, these data were unavailable in our medical record. Prompt radiologic confirmation continues to be viewed as most appropriate in determining ETT placement. A prospective study is needed to confirm and better control for these issues.

Conclusions

A weight-based institutional formula used clinically had a low sensitivity for predicting proper ETT depth. Weight-based formulas may have clinical utility; however, analysis of current data indicated that the accuracy of these formulas was poor in infants < 1 kg. Rapid radiologic assessment of ETT placement is necessary.

Footnotes

  • Correspondence: Renee M Bartle RRT, Respiratory Care Services, Duke University Medical Center, 2301 Erwin Rd, Durham, NC 27710. E-mail: renee.bartle{at}duke.edu.
  • The authors have disclosed no conflicts of interest.

  • See the Related Editorial on Page 350

  • Copyright © 2019 by Daedalus Enterprises

References

  1. 1.↵
    1. Saboo AR,
    2. Dutta S,
    3. Sodhi KS
    . Digital palpation of endotracheal tube tip as a method of confirming endotracheal tube position in neonates: an open-label, three-armed randomized controlled trial. Paediatr Anaesth 2013;23(10):934–939.
    OpenUrl
  2. 2.↵
    1. Amarilyo G,
    2. Mimouni FB,
    3. Oren A,
    4. Tsyrkin S,
    5. Mandel D
    . Orotracheal tube insertion in extremely low birth weight infants. J Pediatr 2009;154(5):764–765.
    OpenUrlPubMed
  3. 3.↵
    1. Niwas R,
    2. Nadroo AM,
    3. Sutija VG,
    4. Gudavalli M,
    5. Narula P
    . Malposition of endotracheal tube: association with pneumothorax in ventilated neonates. Arch Dis Child Fetal Neonatal Ed 2007;92(3):F233–F234.
    OpenUrlFREE Full Text
  4. 4.↵
    1. Nacheli GC,
    2. Sharma M,
    3. Wang X,
    4. Gupta A,
    5. Guzman JA,
    6. Tonelli AR
    . Novel device (AirWave) to assess endotracheal tube migration: a pilot study. J Crit Care 2013;28(4):535.e1–e8.
    OpenUrl
  5. 5.↵
    1. Sharma D,
    2. Tabatabaii SA,
    3. Farahbakhsh N
    . Role of ultrasound in confirmation of endotracheal tube in neonates: a review. J Matern Fetal Neonatal Med 2017;1–9.
  6. 6.↵
    1. Pinheiro JM,
    2. Munshi UK
    . Factors contributing to endobronchial intubation in neonates. Pediatr Crit Care Med 2015;16(1):54–58.
    OpenUrl
  7. 7.↵
    1. Thayyil S,
    2. Nagakumar P,
    3. Gowers H,
    4. Sinha A
    . Optimal endotracheal tube tip position in extremely premature infants. Am J Perinatol 2008;25(1):13–16.
    OpenUrlPubMed
  8. 8.↵
    1. Tochen ML
    . Orotracheal intubation in the newborn infant: a method for determining depth of tube insertion. J Pediatr 1979;95(6):1050–1051.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Kattwinkel J,
    2. Perlman JM,
    3. Aziz K,
    4. Colby C,
    5. Fairchild K,
    6. Gallagher J,
    7. et al
    .; American Heart Association. Neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Pediatrics 2010;126(5):e1400–e1413.
    OpenUrlFREE Full Text
  10. 10.↵
    1. Peterson J,
    2. Johnson N,
    3. Deakins K,
    4. Wilson-Costello D,
    5. Jelovsek JE,
    6. Chatburn R
    . Accuracy of the 7-8-9 Rule for endotracheal tube placement in the neonate. J Perinatol 2006;26(6):333–336.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Kempley ST,
    2. Moreiras JW,
    3. Petrone FL
    . Endotracheal tube length for neonatal intubation. Resuscitation 2008;77(3):369–373.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Szpinda M,
    2. Daroszewski M,
    3. Woźniak A,
    4. Szpinda A,
    5. Mila-Kierzenkowska C
    . Tracheal dimensions in human fetuses: an anatomical, digital and statistical study. Surg Radiol Anat 2012;34(4):317–323.
    OpenUrlPubMed
  13. 13.↵
    1. Flinn AM,
    2. Travers CP,
    3. Laffan EE,
    4. O'Donnell CP
    . Estimating the endotracheal tube insertion depth in newborns using weight or gestation: a randomised trial. Neonatology 2015;107(3):167–172.
    OpenUrl
  14. 14.↵
    1. Sakhuja P,
    2. Finelli M,
    3. Hawes J,
    4. Whyte H
    . Is It Time to Review Guidelines for ETT Positioning in the NICU? SCEPTIC-Survey of Challenges Encountered in Placement of Endotracheal Tubes in Canadian NICUs. Int J Pediatr 2016;2016:1–8.
    OpenUrl
  15. 15.↵
    1. Leung C
    . Optimal insertion depth for endotracheal tubes in extremely low-birth-weight infants. Pediatr Crit Care Med 2018;19(4):328–331.
    OpenUrl
PreviousNext
Back to top

In this issue

Respiratory Care: 64 (3)
Respiratory Care
Vol. 64, Issue 3
1 Mar 2019
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evaluating Endotracheal Tube Depth in Infants Weighing Less Than 1 Kilogram
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Evaluating Endotracheal Tube Depth in Infants Weighing Less Than 1 Kilogram
Renee M Bartle, Andrew G Miller, Anthony J Diez, P Brian Smith, Michael A Gentile, Mihai Puia-Dumitrescu
Respiratory Care Mar 2019, 64 (3) 243-247; DOI: 10.4187/respcare.06202

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Evaluating Endotracheal Tube Depth in Infants Weighing Less Than 1 Kilogram
Renee M Bartle, Andrew G Miller, Anthony J Diez, P Brian Smith, Michael A Gentile, Mihai Puia-Dumitrescu
Respiratory Care Mar 2019, 64 (3) 243-247; DOI: 10.4187/respcare.06202
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • endotracheal tube placement
  • neonates
  • premature neonates

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire