Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Open Forum
    • 2023 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Open Forum
    • 2023 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleOriginal Research

Reproducibility and Validity of the 6-Minute Stationary Walk Test Associated With Virtual Reality in Subjects With COPD

Maria CM Frade, Ivanize MM dos Reis, Renata P Basso-Vanelli, Alexandre F Brandão and Mauricio Jamami
Respiratory Care April 2019, 64 (4) 425-433; DOI: https://doi.org/10.4187/respcare.06237
Maria CM Frade
Spirometry and Respiratory Physiotherapy Laboratory, Universidade Federal de São Carlos, São Carlos, São Paulo, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ivanize MM dos Reis
Spirometry and Respiratory Physiotherapy Laboratory, Universidade Federal de São Carlos, São Carlos, São Paulo, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Renata P Basso-Vanelli
Hospital Universitário of Universidade Federal de São Carlos, São Carlos, São Paulo, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alexandre F Brandão
Universidade Estadual de Campinas, Campinas, São Paulo, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mauricio Jamami
Universidade Federal de São Carlos, São Carlos, São Paulo, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND: The importance of evaluating the functional capacity of patients with COPD is well known, and there is a wide range of tests described in the literature. The 6-min stationary walk test associated with virtual reality (STVR-6) was created in light of the current limitations of evaluation tests. It does not require a large physical space or sophisticated equipment, and it is not costly; furthermore, it can be performed by a single rater. The objective of this study was to evaluate intra- and inter-rater reproducibility and to verify the criterion validity of the STVR-6.

METHODS: 50 subjects with COPD were evaluated over the course of 3 d. The execution order of the tests was randomized; the STVR-6 was performed over 2 d, and the 6-min walk test was performed in 1 d. The 6-min walk distance variables and number of steps in the STVR-6 were obtained with a gas analysis performed for both tests.

RESULTS: Relative reproducibility was found for intraclass correlation coefficient values (0.57–0.94, P < .001) between the number of steps and the highest value of oxygen consumption during the test (V̇O2 peak), intra- and inter-rater. In terms of absolute reproducibility, the standard error of measurement and minimum detectable difference values were verified. In the Bland-Altman analysis, the intra- and inter-rater mean difference values were 21 and 17 steps and 0.002 and 0.242 mL/min/kg, respectively. Pearson correlation values were 0.57–0.75 (P < .001) between the number of steps and V̇O2 peak.

CONCLUSIONS: STVR-6 had excellent intra-rater reproducibility and excellent to good inter-rater reproducibility, but the high values of error measures demonstrated that there is a learning effect and a need to perform at least 2 tests. In addition, there was high to moderate correlation between the STVR-6 and the 6-min walk test. Therefore, the STVR-6 proved to be reproducible and valid for evaluating the functional capacity of subjects with COPD.

  • COPD
  • exercise test
  • reproducibility
  • reliability
  • criterion validity
  • virtual reality

Introduction

COPD may lead to a reduction in tolerance to physical exercise and quality of life.1,2 In view of these changes and their possible consequences, evaluating the functional capacity of patients with COPD is extremely important to determine individualized behaviors and treatment programs. Different tests are described in the literature for this purpose, each with specific characteristics, objectives, and limitations.3–6

The 6-min walk test (6MWT) is one of these tests, and it is widely used because it is sensitive to change after pulmonary rehabilitation programs and the distance traveled, and because it is a valid and reproducible test.3 It is also a predictor of mortality, particularly for COPD, and it is highly associated with the risk of hospitalization in people with chronic respiratory diseases.3,4 It is recommended that the 6MWT is performed twice due to the learning effect.3

However, the 6MWT is very sensitive to variations in the methodology because the consistency of the test depends on several factors, such as offering encouragement and using supplemental oxygen and medications.3,4 The place where the test is performed, using gait devices, the team's training, instruction and preparation of the patients, and factors for interrupting the test may also alter the results obtained.3,4 It is important to be aware of these factors to choose the best option among the available evaluation tests and when interpreting the results.

Another example of a functional capacity assessment test is the stationary gait test, described for the first time in the literature as a 2-min stationary gait test of controlled cadence.5 The performance in this test has a moderate correlation with the performance in the 1-mile walk test and the treadmill walk test. It also shows a perception of effort comparable to the 6MWT in the elderly.6,7 It was observed that the test was valid and had good sensitivity and specificity to evaluate the functional capacity of hypertension in the elderly, with and without associated chronic conditions.8

Therefore, our research group proposed a 6-min stationary walk test associated with virtual reality (STVR-6).9 Virtual reality integrates the user with a synthetic 3-dimensional environment,10 creating an immersive and interactive virtual experience that occurs in real time. It also stimulates the active participation of patients even with physical and cognitive disability.11 This potential new test option does not require a large physical space or sophisticated expensive equipment, and it requires only one rater. Furthermore, it provides patients with an integrative and fun assessment in a practical and simple way. To allow for the use of the STVR-6 in clinical practice, it is important to test its reproducibility and validity in subjects with COPD. Thus, this study aimed to evaluate the intra- and inter-rater reproducibility of the STVR-6, as well as to assess the criterion validity by correlation of the STVR-6 with the 6MWT in subjects with COPD.

QUICK LOOK

Current knowledge

Among tests that have been described to evaluate the functional capacity of subjects with COPD, the 6-min walk test (6MWT) presents some limitations in execution. Therefore, the 6-min stationary walk test associated with virtual reality (STVR-6) was developed. It is not costly, and it can be performed by a single rater while providing the patient with an integrative evaluation in a practical way.

What this paper contributes to our knowledge

The STVR-6 had excellent relative intra-rater reproducibility and excellent to good inter-rater reproducibility. However, high values of error measures were found, emphasizing that at least 2 tests need to be carried out per subject due to the learning effect. In addition, the STVR-6 was also valid for evaluating the functional exercise capacity of subjects with COPD.

Methods

This observational and cross-sectional study was developed in the Spirometry and Respiratory Physiotherapy Laboratory at the Federal University of São Carlos (UFSCar). Subjects were recruited using a laboratory database and were screened at the following health centers: UFSCar Health Center School, Municipal Specialty Center, Family Health Centers, and Basic Health Centers in São Carlos. The study was approved by the Research Ethics Committee at UFSCar (no. 1,884,641). All subjects signed a free and informed consent form in accordance with Resolution 466/2012 of the National Health Council.

The subjects included in the study were of both genders ages of 50–80 y who were diagnosed with COPD confirmed by physician-performed spirometry (FEV1/FVC < 70% post-bronchodilator) with mild (stage I) to very severe (stage IV) obstruction (FEV1% predicted > 80 and < 30).12,13 The subjects were clinically stable, had no history of infections or exacerbation of respiratory symptoms or change of medications in the 3 months prior to the study, and scored > 25 in the Mini-Mental State Examination questionnaire to assess cognitive ability.

Individuals who had a body mass index of ≥ 35 kg/m2 were excluded, as well as those who did not complete all the evaluations of the proposed protocol, used supplemental oxygen at home, or showed signs of associated comorbidities, such as rheumatic, orthopedic, neurological, and other associated heart diseases (uncontrolled) that would prevent them from following the proposed protocol. This also included any other respiratory disease besides COPD.

Experimental Procedures

The subjects were submitted to 3 d of evaluations with a minimum interval of 24 h between the tests; a maximum period of 1 week was established to complete all tests, which were always performed at the same time of the day.14 On the first day, a complete anamnesis and physical exam were performed on the subjects. This included an evaluation of cognition by Mini-Mental State Examination and anthropometric measurements, such as body mass and height on an anthropometric scale (WELMY, Santa Bárbara d'Oeste, Brazil). The test to be performed (ie, STVR-6 or 6MWT) was chosen randomly with the use of a randomization web site.15 On this site, the second generator was selected, which provides a random balanced permutation of the evaluations, and the total number of subjects, to determine the 3 evaluations for each subject (6MWT, STVR-6-Rater 1, and STVR-6-Rater 2).15

Consequently, the subjects randomly performed the STVR-6 on 2 different days applied by 2 different raters (Rater 1 or 2) and the 6MWT on another day. All tests were performed twice in the same day with an interval of 30 min between them.16 In addition, on the second day during the interval of the tests, subjects completed the International Physical Activity Questionnaire to assess the level of physical activity of each subject. The International Physical Activity Questionnaire enables the rater to obtain physical activity measurements, which are internationally comparable. The short version contains 7 questions that can estimate the time spent in different dimensions of physical activity. This test's validity was verified in Brazil by Matsudo et al.17 After their application, subjects were classified as very active, active, irregularly active (A and B) and sedentary.18 Figure 1 shows an example of randomization and how the evaluation sequence was given.

Fig. 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.

Timeline of the experimental procedure of the study. MMSE = Mini-Mental State Examination; IPAQ = International Physical Activity Questionnaire. **Maximum period to complete the evaluations. *Example of a random selection, not necessarily everyone followed in that order.

Functional Tests

Subjects were asked to wear comfortable clothing and footwear suitable for walking, to take their regular medication without interruptions, and to refrain from stimulating beverages, smoking, and vigorous physical activity on the day of the evaluation. They were also asked to rest for at least 15 min before initiating the test to stabilize cardiorespiratory variables.3

In the 6MWT and STVR-6, subject heart rate was monitored with a cardio-frequency meter (POLAR, Kempele, Oulu, Finland), SpO2 was measured with a portable pulse oximeter (Nonin Medical, Minneapolis, Minnesota), and the sensation of dyspnea and fatigue of lower limbs was assessed with the Borg CR10 scale,19 in addition to pressure variables measured with a sphygmomanometer (BIC, Itupeva, Brazil) and stethoscope (Littmann, Elmhurst, Illinois). During the tests every minute, the heart rate and SpO2 were performed, and before and in the recovery period (up to 6 minutes after the test) all measurements, heart rate, SpO2, dyspnea, fadigue and blood pressure were performed. A pedometer (DIGI-WALKER, SW 701, Tokyo, Japan) fixed to the middle anterior region of the right thigh of the subject was used to measure the number of steps.

During the tests, gas analyses were performed with the VO2000 model analyzer (MedGraphics, St Paul, Minnesota) using a low-flow, 2-way pneumotachograph coupled to a mask. The system measures micro-samples of expired gases using the mean collection method every 10 s.20 During the 6MWT, the portable form was used with an out-patient kit, which utilized a pneumotachograph, mouthpiece, neoprene mask, and band. The data produced loaded into a computer in real time via a serial port and plotted on V̇O2 graphs to show the volume of oxygen consumed in L/min expressed at standard temperature and dry pressure.

Prior to starting the test, the subjects remained in the standing position at the test site for 1 min to collect the baseline variables of the respiratory gases. The 6MWT was performed in a corridor 30 m long and 1.5 m wide, with markings every 2 m and the first and 30th meters marked with a cone and a line, to mark the beginning and the end. Subjects received test instructions to walk as far as possible without running in 6 min,3 which is the 6-min walk distance (6MWD). Moreover, encouraging remarks were made every minute according to American Thoracic Society standardizations.21

In the STVR-6, the subjects carried out stationary walking for 6 min using virtual reality. When asked to begin, the subjects started the stationary walk (without running), completing as many steps as possible within the given time, and the number of steps was determined. The minimum knee height, customized for each subject, was leveled at a midpoint between the patella and the anterior superior iliac spine.5,22 Standardized encouragement was given to the subjects every minute of the test using an adaptation of American Thoracic Society standards.3,21

Associated with the stationary gait test was a virtual reality application, GestureMaps, developed in the Immersive, Interactive, and Collaborative Visualization Laboratory at UFSCar, which was deployed in an air-conditioned room with an X-box Kinect (Microsoft, Redmond, Washington). This allowed navigation in different scenarios using the virtual Google Street View map. In this study, all of the subjects were positioned to begin the test at an address on São Carlos Avenue, in the city of São Carlos, São Paulo. This navigation is done by controlling an avatar with gestures that simulate the stationary gait. Hip and knee flexion movements make the individual “walk” on the map, and lateral flexion of the trunk to the right or left enables the subject to change direction (Fig. 2).23

Fig. 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.

Subject performing the 6-min stationary walk test associated with virtual reality.

Because this test requires some unusual movements, a familiarization protocol of 1 min was adopted on the first day of the STVR-6, performed by both Rater 1 and Rater 2, depending on the randomization.

Statistical Analysis

For the sample size calculation, 50 subjects were needed for the sample size to be considered “good” according to the consensus-based Standards for Health Measurement Instruments.24 The normality of the data were verified using the Komolgorov-Smirnov test. Data were presented as mean ± SD means for parametric variables or as median (interquartile range) for non-parametric variables. The paired Student t test and the Wilcoxon test were used for the parametric and non-parametric variables, respectively, in the intragroup comparison. When the mean of the difference between the 2 STVR-6 outcomes was obtained, the test performed by Rater 1 was selected and the best STVR-6 (ie, test with the greatest number of steps) was selected. The data were analyzed using SPSS (version 20.0, Chicago, Illinois). Significance level of P < .05 and 95% CI were considered.

The relative intra- and inter-rater reproducibility was verified through the ICC.25 The intra-rater reproducibility was tested with the first and second tests performed by both Raters 1 and 2, depending on the random drawing. In the inter-rater analysis, the best test of each of the 2 raters was selected, based on the number of steps; we considered values < 0.4 to indicate low reproducibility, values between 0.4 and 0.75 to indicate good reproducibility, and values > 0.75 to indicate excellent reproducibility.26

The absolute reproducibility was verified by the standard error of measurement (SEM), calculated as SD × √(1 − ICC); the SD was the largest SD found between the 2 compared tests, and 95% CI was calculated as SEM × 1.96.27 The minimum detectable difference (MDD) was calculated as MDD = 1.64 × √(2) × SEM, as well as the Bland-Altman analysis.25,28

For the criterion validation, correlations were made between the 6MWT Test 1, Test 2, and the best among the STVR-6 Test 1, Test 2, and the best one performed by Rater 1. The test was characterized as valid when the Pearson correlation coefficient (r) was > 0.7.27 In addition, r values ranging from 1.0 to 0.9 were considered as very high correlation, 0.89–0.7 as high, 0.69–0.5 as moderate, 0.49–0.26 as low, and 0.25–0 as small to no correlation.29

Results

A total of 153 individuals with COPD were screened, of whom 92 were excluded. The remaining 61 subjects were evaluated. In this stage, 11 were excluded due to associated comorbidities, 3 dropped out, 3 had pre-test desaturation, and 1 subject had an exacerbation, leaving 50 subjects in the statistical analysis (Fig. 3).

Fig. 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 3.

Flow chart. BMI = body mass index.

Subject characteristics can be seen in Table 1. Most of the subjects were men with a body mass index from normal weight to obese I, and 74% were former smokers. They were classified according to GOLD12 as mild to very severe obstruction; with regard to the level of physical activity, 36% were considered active and only 10% were sedentary.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1.

Key Characteristics and Level of Physical Activity of Subjects

A significant increase in the number of steps of an average of 24.7 steps was observed in STVR-6 Test 2 compared to STVR-6 Test 1, performed by the same rater (Rater 1). In addition, when comparing the best STVR-6 and the best 6MWT also performed by Rater 1, a significant difference was observed for the V̇O2 peak, nadir SpO2 (lower oxygen saturation value during the test), and the sensation of fatigue. All values were higher in STVR-6 (Table 2).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 2.

Data Obtained in the STVR-6 and 6MWT

The results obtained for relative intra-rater reproducibility of the STVR-6 were excellent for the number of steps and V̇O2 peak variables between the 2 tests (Table 3). The relative inter-rater reproducibility was good for V̇O2 peak and excellent for the number of steps when comparing the best tests of each rater (Table 3).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 3.

Relative Intra-Rater and Inter-Rater Reproducibility of the STVR-6

Absolute reproducibility was verified with SEM and MDD. For the number of steps, the SEM was 49.6 (95% CI 97.2), and the MDD was 115.1 for intra-rater. In the inter-rater analysis for this same variable, the SEM was 54.6 (95% CI 106.9), and the MDD was 126.5. For V̇O2 peak, the SEM was 1.5 (95% CI 2.9), and the MDD was 3.4 for intra-rater; in the inter-rater analysis, the SEM was 2.2 (95% CI 4.3), and the MDD was 5.1.

Bland-Altman analysis (Fig. 4) showed that the mean difference was 21 steps (CI −117.5 to 159.5 steps) and 0.002 mL/min/kg for V̇O2 peak (CI −3.8 to 4.2 mL/min/kg) intra-rater, and the inter-rater mean difference was 17 steps (CI −135.0 to 169.1 steps) and 0.242 mL/min/kg for V̇O2 peak (CI −5.8 to 6.3 mL/min/kg).

Fig. 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 4.

Bland-Altman graph of the 6-min stationary walk test associated with virtual reality (STVR-6). The horizontal solid line represents the mean of the differences, and the dotted lines represent the 95% CI. (A) Performance between the first (Test 1) and second (Test 2) STVR-6. (B) Performance between the first (Rater 1) and the second (Rater 2) STVR-6 rater. (C) Corrected value of peak oxygen consumption (V̇O2) between the first (Test 1) and second (Test 2) STVR-6. (D) Corrected value of V̇O2 between the first (Rater 1) and the second (Rater 2) rater.

The criterion validation was verified by the correlations between STVR-6 and 6MWT variables. It high correlation was observed between the V̇O2 peak values of the tests, and a moderate correlation was recognized between the 6MWD and the number of steps in STVR-6 (Table 4).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 4.

Correlation Between Performance and V̇O2 Peak in the STVR-6 and the 6MWT

Discussion

This study verified that the proposed STVR-6 has excellent intra-rater reproducibility and excellent to good inter-rater reproducibility, although error measurements presented high values. This proposed test also proved to be valid. Studies have shown the efficacy of the stationary gait test for other populations such as the healthy elderly and subjects with arterial hypertension, heart failure, and cervical compressive myeloma.30,22,31,32

The STVR-6 is a functional capacity assessment test that only requires a small space. Moreover, it is practical and simple to use. Alternatively, it can be performed in the hospital environment for acute conditions with better monitoring.31 It is considered safe because it avoids falls, and it can be performed using walking aids. It can also be used by individuals with altered balance.30,31 This test favors patients with COPD who use supplemental oxygen because the oxygen cylinder does not need to be transported while carrying out the test.

In this study, we proposed associating the stationary gait test with virtual reality because it may encourage greater patient interaction and motivation, and virtual reality is increasingly used in pulmonary rehabilitation programs. Liu et al33 proposed a functional capacity assessment test using the Gait Real-Time Analysis Interactive Lab, in which a self-directed treadmill designed on a 180-degree screen was used. This test proved to be reliable and valid for evaluating the elderly and COPD subjects.

The virtual reality may have a direct influence on test performance or exercise practice. In our study, the mean V̇O2 peak obtained in STVR-6 was higher than that in the 6MWT. This may be due to the higher motivation in the virtual reality setting, but it could also be an intrinsic characteristic of STVR-6 because nadir SpO2 and fatigue were significantly higher in this test when compared to the 6MWT. However, we do not know of any studies that performed the stationary gait test without virtual reality with gas analysis to confirm this possibility.

In clinical practice, it is important for the evaluation tool to be reliable, validated, and easy to perform; for this reason, we examined the psychometric properties of functional tests.34 We found that STVR-6 presented excellent intra-rater reproducibility (ICC values for the various measures were 0.80–0.94), and similar results were found with the 6MWD (ICC 0.93) and changes in the SpO2 (ICC 0.81), heart rate (ICC 0.62), and fatigue sensation on the Borg scale (ICC 0.59).35 The relative inter-rater reproducibility, on the other hand, presented a good value (ICC 0.57) for the V̇O2 peak and an excellent value (ICC 0.93) for the number of steps. This good relative reproducibility for V̇O2 peak can be accounted for by the fact that the variable is very accurate and has low variability, which lowers the coefficient of variation; therefore, error measurements may be the most accurate method for verifying reproducibility.

High values for the error measures of the number of steps were obtained in absolute reproducibility. These measures were obtained with a pedometer, whose reproducibility and accuracy were confirmed in previous studies even at high speeds (eg, during exercise).36,37 Therefore, this pedometer was not responsible for the error measures obtained. In the Bland-Altman graph, 66% of the sample increased the number of steps between Test 1 and Test 2. In addition, the mean difference was 17 steps. When we relativized the mean difference by the average of the performance in the test, we found an increase of 5.2%. Likewise, other authors observed that the mean difference found in the 6MWT was 27 m, and that they obtained an increase of 7% when they relativized the mean difference by the 6MWD.35 This demonstrates a learning effect between Test 1 and Test 2. We therefore suggest that the STVR-6 should be done at least 2 times, just as the American Thoracic Society has recommended for the 6MWT.21

For validation, we correlated 6MWT variables because there are studies that have demonstrated the criterion and construct validity of this test for subjects with COPD, which are considered functional capacity assessment,38 as well as a relationship with the maximum exercise capacity.4 In addition, 6MWD has been shown to be a good predictor of mortality.39 It also shows the similarities of the tests regarding the duration and characteristic of free cadence.

In our study, there was a high to moderate and significant positive correlation between the tests. Similar values were found to validate the 6MWT (0.4–0.93), and the highest correlations were between measurements of maximum physical performance and physical activity.3 Similarly, a high correlation of 0.78 between maximum V̇O2 in the cardiopulmonary exercise test and the 6MWD has been reported in the literature, as well as a correlation of 0.85 between the 6MWD and the V̇O2 peak in the 6MWT.39–41

Because the V̇O2 peak values were highly correlated between the tests, this variable was selected as the main one to confirm validity, as has been done in other studies.42 Thus, STVR-6 is a functional capacity assessment test and may be an alternative to the 6MWT, considering some negative aspects of the 6MWT, such as the physical space needed.

One limitation to consider in our study is the use of a convenience sample by selecting subjects from the city of São Carlos. Consequently, our study does not have as many subjects as other stratifications in disease severity or in different levels of physical activity. Another limitation is that we did not evaluate subjects, who, because they are elderly, could experience some impairment in this function and thus interfere with the stationary gait. In addition, we did not measure the length of the subjects' steps, which might relate to the distance covered in the STVR-6 and could be correlated with the 6MWD.

Conclusion

The STVR-6 had excellent intra-rater reproducibility and has excellent to good inter-rater reproducibility, but high values of error measurements demonstrate that there is a learning effect and each subject should perform the test twice. The STVR-6 had a high correlation with the 6MWT with regard to V̇O2 peak and a moderate correlation with the number of steps. Thus, the STVR-6 proved reproducible and valid to evaluate the functional capacity of subjects with COPD and may be an alternative to the 6MWT.

Footnotes

  • Correspondence: Mauricio Jamami PT, Rodovia Washington Luiz, Km 235, Laboratório de Espirometria e Fisioterapia Respiratória (DFisio), CEP: 13565–905, São Carlos, SP, Brazil. E-mail: mjamami{at}gmail.com.
  • The authors have disclosed a relationship with the Brazilian National Council for Scientific and Technological Development.

  • Copyright © 2019 by Daedalus Enterprises

References

  1. 1.↵
    1. Dourado VZ,
    2. Tanni SE,
    3. Vale SA,
    4. Faganello MM,
    5. Sanchez FF,
    6. Godoy I
    . Systemic manifestations in chronic obstructive pulmonary disease. J Bras Pneumol 2006;32(2):161–171.
    OpenUrlPubMed
  2. 2.↵
    1. Miranda EF,
    2. Malaguti C,
    3. Corso SD
    . Peripheral muscle dysfunction in COPD: lower limbs versus upper limbs. J Bras Pneumol 2011;37(3):380–388.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Holland AE,
    2. Spruit MA,
    3. Troosters T,
    4. Puhan MA,
    5. Pepin V,
    6. Saey D,
    7. et al
    . An official European Respiratory Society/American Thoracic Society technical standard: field walking tests in chronic respiratory disease. Eur Respir J 2014;44(6):1428–1446.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Singh SJ,
    2. Puhan MA,
    3. Andrianopoulos V,
    4. Hernandes NA,
    5. Mitchell KE,
    6. Hill CJ,
    7. et al
    . An official systematic review of the European Respiratory Society/American Thoracic Society: measurement properties of field walking tests in chronic respiratory disease. Eur Respir J 2014;44(6):1447–1478.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Rikli RE,
    2. Jones CJ
    . Development and validation of a functional fitness test for community-residing older adults. J Aging Phys Act 1999;7(2):129–161.
    OpenUrlCrossRef
  6. 6.↵
    1. Wilkin LD,
    2. Haddock BL
    . Functional fitness of older adults. Activities Adapt Aging 2011;35(3):197–209.
    OpenUrl
  7. 7.↵
    1. Jones CJ,
    2. Rikli RE
    . Measuring functional fitness in older adults. J Active Ageing 2002;1:25–30.
    OpenUrl
  8. 8.↵
    1. Guedes MBOG,
    2. Lopes JM,
    3. Andrade AdS,
    4. Guedes TSR,
    5. Ribeiro JM,
    6. Cortez LCdA
    . Validation of the two minute step test for diagnosis of the functional capacity of hypertensive elderly persons. Rev Bras Geriatr Gerontol 2015;18(4):921–926.
    OpenUrl
  9. 9.↵
    1. Sakaguchi CA,
    2. Jamami M
    . Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual: uma alternativa ao teste de caminhada de seis minutos? https://repositorio.ufscar.br/handle/ufscar/8790. Accessed January 27, 2018.
  10. 10.↵
    1. Teixeira K,
    2. Pimentel K
    . Virtual reality: through the new looking glass. Blue Ridge Summit, PA: Windcrest; 1995.
  11. 11.↵
    1. Deutsch JE
    . Using virtual reality to improve walking post-stroke: translation to individuals with diabetes. J Diabetes Sci Technol 2011;5(2):309–314.
    OpenUrlCrossRefPubMed
  12. 12.↵
    Global Initiative for Chronic Obstructive Lung Disease (GOLD). Global strategy for Diagnosis, Management, and Prevention of COPD: revised 2018. https://goldcopd.org/wp-content/uploads/2017/11/GOLD-2018-v6.0-FINAL-revised-20-Nov_WMS.pdf. Accessed January 27, 2018.
  13. 13.↵
    1. Vestbo J,
    2. Hurd SS,
    3. Agustí AG,
    4. Jones PW,
    5. Vogelmeier C,
    6. Anzueto A,
    7. et al
    . Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: GOLD executive summary. Am J Respir Crit Care Med 2013;187(4):347–365.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Eiser N,
    2. Willsher D,
    3. Doré CJ
    . Reliability, repeatability and sensitivity to change of externally and self-paced walking tests in COPD patients. Respir Med 2003;97(4):407–414.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Dalla GE
    . Randomization.com. http://www.randomization.com. Accessed January 30, 2017.
  16. 16.↵
    1. Fonseca JFdN,
    2. Morita AA,
    3. Bisca GW,
    4. Britto IL,
    5. Castro LA,
    6. Felcar JM,
    7. et al
    . Are thirty minutes of rest between two 6-minute walk tests enough for cardiovascular and symptomatic recovery for patients with chronic obstructive pulmonary disease? Fisioter Pesq 2015;22(3):325–332.
    OpenUrl
  17. 17.↵
    1. Matsudo S,
    2. Araujo T,
    3. Matsudo V,
    4. Andrade D,
    5. Andrade E,
    6. Oliveira LC,
    7. et al
    . Physical activity questionnaire (IPAQ): study of validity and reliability in Brazil. Rev Bras Ativ Fis Saude 2001;6(2):6–17.
    OpenUrl
  18. 18.↵
    1. Silva GSF,
    2. Bergamaschine R,
    3. Rosa M,
    4. Melo C,
    5. Miranda R,
    6. Bara Filho M
    . Evaluation of the physical activity level of undergraduate students of health/biology fields. Rev Bras Med Esporte 2007;13(1):39–42.
    OpenUrl
  19. 19.↵
    1. Borg GA
    . Psychophysical bases of perceived exertion. Med Sci Sports Exerc 1982;14(5):377–381.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Crouter SE,
    2. Antczak A,
    3. Hudak JR,
    4. DellaValle DM,
    5. Haas JD
    . Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems. Eur J Appl Physiol 2006;98(2):139–151.
    OpenUrlCrossRefPubMed
  21. 21.↵
    American Thoracic Society. ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med 2002;166(1):111–117.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Pedrosa R,
    2. Holanda G
    . Correlation between the walk, 2-minute step and tug tests among hypertensive older. Rev Bras Fisioter 2009;13(3):252–256.
    OpenUrlCrossRef
  23. 23.↵
    1. Brandão AF,
    2. Dias DRC,
    3. Guimarães MP,
    4. Trevelin LC,
    5. Parizotto NA,
    6. Castellano G
    . GestureCollection for motor and cognitive stimuli: virtual reality and eHealth prospects. J. Health Inform 2018;10(1):9–16.
    OpenUrl
  24. 24.↵
    1. Mokkink LB,
    2. Terwee CB,
    3. Patrick DL,
    4. Alonso J,
    5. Stratford PW,
    6. Knol DL,
    7. et al
    . The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study. Qual Life Res 2010;19(4):539–549.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Kottner J,
    2. Audige L,
    3. Brorson S,
    4. Donner A,
    5. Gajewski BJ,
    6. Hróbjartsson A,
    7. et al
    . Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. Int J Nurs Stud 2011;48(6):661–671.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Fleiss JL
    . The design and analysis of clinical experiments. New York: John Wiley; 1986.
  27. 27.↵
    1. Waltson DM,
    2. Macdermid JC,
    3. Nielson WR,
    4. Teasell RW,
    5. Chiasson M,
    6. Brown L
    . Reliability, standard error and minimum detectable change of clinical pressure pain threshold testing in people with and without acute neck pain. J Orthop Sports Phys Ther 2011;41(9):644–650.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Terwee CB,
    2. Bot SD,
    3. de Boer MR,
    4. van der Windt DA,
    5. Knol DL,
    6. Dekker J,
    7. et al
    . Quality criteria were proposed for measurement properties of health status questionnaires. J Clin Epidemiol 2007;60(1):34–42.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Munro BH
    . Statistical methods for health care research, 4th ed. Philadelphia: JB Lippincott, 2000.
  30. 30.↵
    1. Różańska-Kirschke AK,
    2. Kocur P,
    3. Wilk M,
    4. Dylewicz P
    . Fullerton Fitness Test as fitness index for the elderly. Med Rehabil 2006;10:15–19.
    OpenUrl
  31. 31.↵
    1. Węgrzynowska-Teodorczyk K,
    2. Mozdzanowska D,
    3. Josiak K,
    4. Siennicka A,
    5. Nowakowska K,
    6. Banasiak W,
    7. et al
    . Could the two-minute step test be an alternative to the six-minute walk test for patients with systolic heart failure? Eur J Prev Cardiol 2016;23(12):1307–1313.
    OpenUrlCrossRefPubMed
  32. 32.↵
    1. Nakashima H,
    2. Yukawa Y,
    3. Ito K,
    4. Machino M,
    5. Kanbara S,
    6. Morita D,
    7. et al
    . Validity of the 10-s step test: prospective study comparing it with the 10-s grip and release test and the 30-m walking test. Eur Spine J 2011;20(8):1318–1322.
    OpenUrlPubMed
  33. 33.↵
    1. Liu WY,
    2. Meijer K,
    3. Delbressine JM,
    4. Willems PJ,
    5. Franssen FM,
    6. Wouters EF,
    7. et al
    . Reproducibility and validity of the 6-minute walk test using the gait real-time analysis interactive lab in patients with COPD and healthy elderly. PLoS One 2016;11(9):e0162444.
    OpenUrl
  34. 34.↵
    1. Liu Y,
    2. Li H,
    3. Ding N,
    4. Wang N,
    5. Wen D
    . Functional status assessment of patients with COPD: a systematic review of performance-based measures and patient-reported measures. Medicine (Baltimore) 2016;95(20):e3672.
    OpenUrl
  35. 35.↵
    1. Hernandes NA,
    2. Wouters EF,
    3. Meijer K,
    4. Annegarn J,
    5. Pitta F,
    6. Spruit MA
    . Reproducibility of 6-minute walking test in patients with COPD. Eur Respir J 2011;38(2):261–267.
    OpenUrlAbstract/FREE Full Text
  36. 36.↵
    1. Furlanetto KC,
    2. Bisca GW,
    3. Oldemberg N,
    4. Sant'Anna TJ,
    5. Morakami FK,
    6. Camillo CA,
    7. et al
    . Step counting and energy expenditure estimation in patients with chronic obstructive pulmonary disease and healthy elderly: accuracy of 2 motion sensors. Arch Phys Med Rehabil 2010;91(2):261–267.
    OpenUrlCrossRefPubMed
  37. 37.↵
    1. Turner LJ,
    2. Houchen L,
    3. Williams J,
    4. Singh SJ
    . Reliability of pedometers to measure step counts in patients with chronic respiratory disease. J Cardiopulm Rehabil Prev 2012;32(5):284–291.
    OpenUrlCrossRefPubMed
  38. 38.↵
    1. Satake M,
    2. Shioya T,
    3. Takahashi H,
    4. Kawatani M
    . Ventilatory responses to six-minute walk test, incremental shuttle walking test, and cycle ergometer test in patients with chronic obstructive pulmonary disease. Biomed Res 2003;24(6):309–316.
    OpenUrlCrossRef
  39. 39.↵
    1. Cote CG,
    2. Pinto-Plata V,
    3. Kasprzyk K,
    4. Dordelly LJ,
    5. Celli BR
    . The 6-min walk distance, peak oxygen uptake, and mortality in COPD. Chest 2007;132(6):1778–1785.
    OpenUrlCrossRefPubMed
  40. 40.
    1. Herdy AH,
    2. Ritt LE,
    3. Stein R,
    4. Araújo CG,
    5. Milani M,
    6. Meneghelo RS,
    7. et al
    . Cardiopulmonary exercise test: background, applicability and interpretation. Arq Bras Cardiol 2016;107(5):467–481.
    OpenUrl
  41. 41.↵
    1. Díaz O,
    2. Morales A,
    3. Osses R,
    4. Klaassen J,
    5. Lisboa C,
    6. Saldías F
    . Six-minute-walk test and maximum exercise test in cycloergometer in chronic obstructive pulmonary disease. Are the physiological demands equivalent? Arch Bronconeumol 2010;46(6):294–301.
    OpenUrlPubMed
  42. 42.↵
    1. Jürgensen SP,
    2. Trimer R,
    3. Dourado VZ,
    4. Di Thommazo-Luporini L,
    5. Bonjorno-Junior JC,
    6. Oliveira CR,
    7. et al
    . Shuttle walking test in obese women: test-retest reliability and concurrent validity with peak oxygen uptake. Clin Physiol Funct Imaging 2015;35(2):120–126.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Respiratory Care: 64 (4)
Respiratory Care
Vol. 64, Issue 4
1 Apr 2019
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reproducibility and Validity of the 6-Minute Stationary Walk Test Associated With Virtual Reality in Subjects With COPD
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Reproducibility and Validity of the 6-Minute Stationary Walk Test Associated With Virtual Reality in Subjects With COPD
Maria CM Frade, Ivanize MM dos Reis, Renata P Basso-Vanelli, Alexandre F Brandão, Mauricio Jamami
Respiratory Care Apr 2019, 64 (4) 425-433; DOI: 10.4187/respcare.06237

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Reproducibility and Validity of the 6-Minute Stationary Walk Test Associated With Virtual Reality in Subjects With COPD
Maria CM Frade, Ivanize MM dos Reis, Renata P Basso-Vanelli, Alexandre F Brandão, Mauricio Jamami
Respiratory Care Apr 2019, 64 (4) 425-433; DOI: 10.4187/respcare.06237
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Methods
    • Results
    • Discussion
    • Conclusion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • COPD
  • exercise test
  • reproducibility
  • reliability
  • criterion validity
  • virtual reality

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire