Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Call for Abstracts
    • 2022 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • Highlighted Articles
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleConference Proceedings

Alarm Strategies and Surveillance for Mechanical Ventilation

Brian K Walsh and Jonathan B Waugh
Respiratory Care June 2020, 65 (6) 820-831; DOI: https://doi.org/10.4187/respcare.07546
Brian K Walsh
Liberty University, Lynchburg, Virginia.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Jonathan B Waugh
Liberty University, Lynchburg, Virginia.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

References

  1. 1.↵
    1. Tume LN,
    2. Kneyber MC,
    3. Blackwood B,
    4. Rose L
    . Mechanical ventilation, weaning practices, and decision making in European PICUs. Pediatr Crit Care Med 2017;18(4):e182-e188.
    OpenUrl
  2. 2.
    1. Tobin M,
    2. Manthous C
    . Mechanical ventilation. Am J Respir Crit Care Med 2017;196(2):P3-P4.
    OpenUrl
  3. 3.↵
    1. Kacmarek RM,
    2. Pirrone M,
    3. Berra L
    . Assisted mechanical ventilation: the future is now. BMC Anesthesiol 2015;15(1):110.
    OpenUrl
  4. 4.↵
    2019 top 10 health technology hazards executive brief: a report from health devices. Plymouth Meeting: ECRI Institute; 2018.
  5. 5.↵
    1. Kowalczyk L
    . Ventilator errors are linked to 119 deaths: warnings are often ignored, missed by overtaxed caregivers. Boston Globe. June 1, 2012.
  6. 6.↵
    1. Love LC,
    2. Millin CJ,
    3. Kerns CD
    . Take precautions with audible alarms on ventilators. Nursing 2011;41(9):65.
    OpenUrl
  7. 7.↵
    1. Ruppel H,
    2. Funk M,
    3. Whittemore R
    . Measurement of physiological monitor alarm accuracy and clinical relevance in intensive care units. Am J Crit Care 2018;27(1):11-21.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    The Joint Commision. Hospital National Patient Safety Goals. Available at: https://www.jointcommission.org/en/standards/national-patient-safety-goals/hospital-2020-national-patient-safety-goals. Accessed April 1, 2020.
  9. 9.↵
    1. Hess DR,
    2. Kallstrom TJ,
    3. Mottram CD,
    4. Myers TR,
    5. Sorenson HM,
    6. Vines DL,
    7. et al
    . Care of the ventilator circuit and its relation to ventilator-associated pneumonia. Respir Care 2003;48(9):869-879.
    OpenUrlAbstract/FREE Full Text
  10. 10.
    1. MacIntyre NR,
    2. Cook DJ,
    3. Ely EW Jr.,
    4. Epstein SK,
    5. Fink JB,
    6. Heffner JE,
    7. et al
    . Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care Medicine. Chest 2001;120(6):375S-395S.
    OpenUrlCrossRefPubMedWeb of Science
  11. 11.
    American Association for Respiratory Care. AARC clinical practice guidelines: endotracheal suctioning of mechanically ventilated patients with artificial airways 2010. Respir Care 2010;55(6):758-764.
    OpenUrlAbstract/FREE Full Text
  12. 12.
    American Association for Respiratory Care. AARC clinical practice guidelines: long-term invasive mechanical ventilation in the home–2007 revision & update. Respir Care 2007;52(8):1056-1062.
    OpenUrlFREE Full Text
  13. 13.
    1. McArthur CD
    . AARC clinical practice guidelines: capnography/capnometry during mechanical ventilation–2003 revision & update. Respir Care 2003;48(5):534-539.
    OpenUrlFREE Full Text
  14. 14.↵
    1. Chang DW
    . AARC clinical practice guidelines: in-hospital transport of the mechanically ventilated patient–2002 revision & update. Respir Care 2002;47(6):721-723.
    OpenUrlPubMed
  15. 15.↵
    American Association for Respiratory Care. AARC clinical practice guideline. Patient-ventilator system checks. Respir Care 1992;37(8):882-886.
    OpenUrlPubMed
  16. 16.↵
    University Health System Consortium, American Association for Respiratory Care. Safe initiation and management of mechanical ventilation white paper. Available at: https://www.aarc.org/aarc-partners-with-uhc-on-mechanical-ventilation-white-paper. Accessed April 1, 2020.
  17. 17.↵
    1. Lawless ST
    . Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med 1994;22(6):981-985.
    OpenUrlCrossRefPubMedWeb of Science
  18. 18.↵
    1. Chambrin MC,
    2. Ravaux P,
    3. Calvelo-Aros D,
    4. Jaborska A,
    5. Chopin C,
    6. Boniface B
    . Multicentric study of monitoring alarms in the adult intensive care unit (ICU): a descriptive analysis. Intensive Care Med 1999;25(12):1360-1366.
    OpenUrlCrossRefPubMedWeb of Science
  19. 19.
    1. Tsien CL,
    2. Fackler JC
    . Poor prognosis for existing monitors in the intensive care unit. Crit Care Med 1997;25:614-619.
    OpenUrlCrossRefPubMedWeb of Science
  20. 20.
    1. Siebig S,
    2. Kuhls S,
    3. Imhoff M,
    4. Gather U,
    5. Scholmerich J,
    6. Wrede CE
    . Intensive care unit alarms–how many do we need? Crit Care Med 2010;38(2):451-456.
    OpenUrlCrossRefPubMedWeb of Science
  21. 21.↵
    1. Cvach M
    . Monitor alarm fatigue: an integrative review. Biomed Instrum Technol 2012;46(4):268-277.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Bonafide CP,
    2. Lin R,
    3. Zander M,
    4. Graham CS,
    5. Paine CW,
    6. Rock W,
    7. et al
    . Association between exposure to nonactionable physiologic monitor alarms and response time in a children’s hospital. J Hosp Med 2015;10(6):345-351.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Pham JC,
    2. Williams TL,
    3. Sparnon EM,
    4. Cillie TK,
    5. Scharen HF,
    6. Marella WM
    . Ventilator-related adverse events: a taxonomy and findings from 3 incident reporting systems. Respir Care 2016;61(5):621-631.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Malkary G
    . Healthcare without bounds: trends in clinical surveillance and analytics. Menlo Park, CA: Spyglass Consulting Group; 2018.
  25. 25.↵
    1. Jungquist CR,
    2. Smith K,
    3. Nicely KL,
    4. Polomano RC
    . Monitoring hospitalized adult patients for opioid-induced sedation and respiratory depression. Am J Nurs 2017;117(3 Suppl 1):S27-S35.
    OpenUrl
  26. 26.↵
    1. Graham KC,
    2. Cvach M
    . Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms. Am J Crit Care 2010;19(1):28-34.
    OpenUrlAbstract/FREE Full Text
  27. 27.
    1. Bennett C,
    2. McNeer R,
    3. Leider C
    . Urgency analysis of audible alarms in the operating room. Presented at the 12th International Society for Music Information Retrieval Conference, held Oct 24–28, 2011, in Miami, Florida.
  28. 28.↵
    1. Bach TA,
    2. Berglund LM,
    3. Turk E
    . Managing alarm systems for quality and safety in the hospital setting. BMJ Open Qual 2018;7(3):e000202.
    OpenUrlAbstract/FREE Full Text
  29. 29.↵
    1. Lipton JA,
    2. Van Ettinger MJB,
    3. Barendse RJ,
    4. Van Dam TB,
    5. Van Der Putten NJHH,
    6. Nelwan SP
    . Alarms on the intensive cardiac care unit. Comput Cardiol 2009;36:253-256.
    OpenUrl
  30. 30.↵
    1. Joshi R,
    2. Mortel HV,
    3. Feijs L,
    4. Andriessen P,
    5. Pul CV
    . The heuristics of nurse responsiveness to critical patient monitor and ventilator alarms in a private room neonatal intensive care unit. PLoS One 2017;12(10):e0184567.
    OpenUrl
  31. 31.↵
    1. Cvach MM,
    2. Stokes JE,
    3. Manzoor SH,
    4. Brooks PO,
    5. Burger TS,
    6. Gottschalk A,
    7. Pustavoitau A
    . Ventilator alarms in intensive care units: frequency, duration, priority, and relationship to ventilator parameters. Anesth Analg 2018 [Epub ahead of print].
  32. 32.↵
    1. Dills CC
    . Managing mechanical ventilator alarms with middleware. Biomed Instrum Technol 2017;51(s2):62-65.
    OpenUrl
  33. 33.↵
    1. Drew BJ,
    2. Harris P,
    3. Zègre-Hemsey JK,
    4. Mammone T,
    5. Schindler D,
    6. Salas-Boni R,
    7. et al
    . Insights into the problem of alarm fatigue with physiologic monitor devices: a comprehensive observational study of consecutive intensive care unit patients. PLoS One 2014;9(10):e110274.
    OpenUrlCrossRefPubMed
  34. 34.↵
    1. Xie H,
    2. Kang J,
    3. Mills GH
    . Clinical review: the impact of noise on patients’ sleep and the effectiveness of noise reduction strategies in intensive care units. Crit Care 2009;13(2):208.
    OpenUrlCrossRefPubMed
  35. 35.↵
    1. Bliss JP,
    2. Gilson RD,
    3. Deaton JE
    . Human probability matching behaviour in response to alarms of varying reliability. Ergonomics 1995;38(11):2300-2312.
    OpenUrlCrossRefPubMedWeb of Science
  36. 36.↵
    1. Edworthy J,
    2. Hellier E
    . Alarms and human behaviour: implications for medical alarms. Br J Anaesth 2006;97(1):12-17.
    OpenUrlCrossRefPubMedWeb of Science
  37. 37.↵
    1. Ruppel H,
    2. Funk M,
    3. Clark JT,
    4. Gieras I,
    5. David Y,
    6. Bauld TJ,
    7. et al
    . Attitudes and practices related to clinical alarms: a follow-up survey. Am J Crit Care 2018;27(2):114-123.
    OpenUrlAbstract/FREE Full Text
  38. 38.↵
    Alarm management becomes an NPSG. Hosp Peer Rev 2013;38(9):105-106.
    OpenUrl
  39. 39.
    Alarm management. Crit Care Nurse 2013;33(5):83-86.
    OpenUrlFREE Full Text
  40. 40.
    Management ED. ED accreditation update. Hospitals put on notice: alarm management is a top priority for 2014. ED Manag 2013;25(9):1-3.
    OpenUrl
  41. 41.
    Alarm management as a patient safety goal. Health Devices 2013;42(8):242-247.
    OpenUrlPubMed
  42. 42.↵
    Alarm management gets renewed focus. Hosp Peer Rev 2013;38(4):39-41.
    OpenUrl
  43. 43.↵
    1. Edworthy J
    . Alarms are still a problem. Anaesthesia 2013;68(8):791-794.
    OpenUrlCrossRefPubMed
  44. 44.↵
    1. Jacques S,
    2. Williams E
    . Reducing the safety hazards of monitor alert and alarm fatigue. Patient Safety Network. Available at: https://psnet.ahrq.gov/perspective/reducing-safety-hazards-monitor-alert-and-alarm-fatigue. Accessed April 1, 2020.
  45. 45.↵
    1. Cvach M,
    2. Kitchens M,
    3. Smith K,
    4. Harris P,
    5. Flack MN
    . Customizing alarm limits based on specific needs of patients. Biomed Instrum Technol 2017;51(3):227-234.
    OpenUrl
  46. 46.↵
    1. Gorges M,
    2. Markewitz BA,
    3. Westenskow DR
    . Improving alarm performance in the medical intensive care unit using delays and clinical context. Anesth Analg 2009;108(5):1546-1552.
    OpenUrlCrossRefPubMedWeb of Science
  47. 47.↵
    1. Ursprung R,
    2. Gray JE,
    3. Edwards WH,
    4. Horbar JD,
    5. Nickerson J,
    6. Plsek P,
    7. et al
    . Real time patient safety audits: improving safety every day. Qual Saf Health Care 2005;14(4):284-289.
    OpenUrlAbstract/FREE Full Text
  48. 48.↵
    1. Sirgo Rodríguez G,
    2. Olona Cabases M,
    3. Martin Delgado MC,
    4. Esteban Reboll F,
    5. Pobo Peris A,
    6. Bodí Saera M
    , ART-SACC Study Experts. Audits in real time for safety in critical care: definition and pilot study. Med Intensiva 2014;38(8):473-482.
    OpenUrl
  49. 49.↵
    1. Christensen M
    . Noise levels in a general intensive care unit: a descriptive study. Nurs Crit Care 2007;12(4):188-197.
    OpenUrlCrossRefPubMed
  50. 50.↵
    1. Makary MA,
    2. Daniel M
    . Medical error-the third leading cause of death in the US. BMJ 2016;353:i2139.
    OpenUrlFREE Full Text
  51. 51.↵
    1. Morris TA,
    2. Gay PC,
    3. MacIntyre NR,
    4. Hess DR,
    5. Hanneman SK,
    6. Lamberti JP,
    7. et al
    . Respiratory compromise as a new paradigm for the care of vulnerable hospitalized patients. Respir Care 2017;62(4):497-512.
    OpenUrlAbstract/FREE Full Text
  52. 52.↵
    1. Lee TW,
    2. Hong JW,
    3. Yoo JW,
    4. Ju S,
    5. Lee SH,
    6. Lee SJ,
    7. et al
    . Unplanned extubation in patients with mechanical ventilation: experience in the medical intensive care unit of a single tertiary hospital. Tuberc Respir Dis 2015;78(4):336-340.
    OpenUrl
  53. 53.↵
    1. Lins C,
    2. Gerka A,
    3. Lupkes C,
    4. Rohrig R,
    5. Hein A
    . Enhancing safety of artificially ventilated patients using ambient process analysis. Stud Health Technol Inform 2018;247:316-320.
    OpenUrl
  54. 54.↵
    1. Bennett C,
    2. Dudaryk R,
    3. Crenshaw N,
    4. Edworthy J,
    5. McNeer R
    . Recommendation of new medical alarms based on audibility, identifiability, and detectability in a randomized, simulation-based study. Crit Care Med 2019;47(8):1050-1057.
    OpenUrl
  55. 55.↵
    1. Niyazmand T,
    2. Izadi I
    . Pattern mining in alarm flood sequences using a modified PrefixSpan algorithm. ISA Trans 2019;90:287-293.
    OpenUrl
  56. 56.↵
    1. Reising DV,
    2. Downs JL,
    3. Bayn D
    . Human performance models for response to alarm notifications in the process industries: an industrial case study. Proceedings of the Human Factors and Ergonomics Society 48th Annual Meeting, Santa Monica, CA, 2004.
PreviousNext
Back to top

In this issue

Respiratory Care: 65 (6)
Respiratory Care
Vol. 65, Issue 6
1 Jun 2020
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Alarm Strategies and Surveillance for Mechanical Ventilation
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Alarm Strategies and Surveillance for Mechanical Ventilation
Brian K Walsh, Jonathan B Waugh
Respiratory Care Jun 2020, 65 (6) 820-831; DOI: 10.4187/respcare.07546

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Alarm Strategies and Surveillance for Mechanical Ventilation
Brian K Walsh, Jonathan B Waugh
Respiratory Care Jun 2020, 65 (6) 820-831; DOI: 10.4187/respcare.07546
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Current State of Alarm Management
    • Challenges in Alarm Monitoring
    • Discussion
    • Acknowledgment
    • Footnotes
    • References
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • mechanical ventilation
  • ventilation
  • alarm
  • alarm management
  • ventilator alarms
  • ventilator alarm management
  • alarms strategy
  • alarm surveillance

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire