Skip to main content
 

Main menu

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Open Forum
    • 2023 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • The Journal

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out

Search

  • Advanced search
American Association for Respiratory Care
  • Subscribe
  • My alerts
  • Log in
  • Log out
American Association for Respiratory Care

Advanced Search

  • Home
  • Content
    • Current Issue
    • Editor's Commentary
    • Archives
    • Most-Read Papers of 2022
  • Authors
    • Author Guidelines
    • Submit a Manuscript
  • Reviewers
    • Reviewer Information
    • Create Reviewer Account
    • Reviewer Guidelines: Original Research
    • Reviewer Guidelines: Reviews
    • Appreciation of Reviewers
  • CRCE
    • Through the Journal
    • JournalCasts
    • AARC University
    • PowerPoint Template
  • Open Forum
    • 2023 Open Forum
    • 2023 Abstracts
    • Previous Open Forums
  • Podcast
    • English
    • Español
    • Portugûes
    • 国语
  • Videos
    • Video Abstracts
    • Author Interviews
    • The Journal
  • Twitter
  • Facebook
  • YouTube
Research ArticleOriginal Research

Performance of Different Active Humidification Systems in High-Flow Oxygen Therapy

Gustavo A Plotnikow, Darío Villalba, Emiliano Gogniat, Corina Quiroga, Eliana Pérez Calvo and José Luis Scapellato
Respiratory Care September 2020, 65 (9) 1250-1257; DOI: https://doi.org/10.4187/respcare.07654
Gustavo A Plotnikow
Division of Physical Therapy and Respiratory Care, Intensive Care Unit, Anchorena Hospital, Buenos Aires City, Buenos Aires, Argentina.
Capítulo de Kinesiología Intensivista, Argentinian Intensive Care Society, Buenos Aires City, Buenos Aires, Argentina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: [email protected]
Darío Villalba
Division of Physical Therapy and Respiratory Care, Intensive Care Unit, Anchorena Hospital, Buenos Aires City, Buenos Aires, Argentina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Emiliano Gogniat
Division of Physical Therapy and Respiratory Care, Clínica Basilea, Buenos Aires City, Buenos Aires, Argentina.
Capítulo de Kinesiología Intensivista, Argentinian Intensive Care Society, Buenos Aires City, Buenos Aires, Argentina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Corina Quiroga
Capítulo de Kinesiología Intensivista, Argentinian Intensive Care Society, Buenos Aires City, Buenos Aires, Argentina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eliana Pérez Calvo
Division of Physical Therapy and Respiratory Care, Clínica Basilea, Buenos Aires City, Buenos Aires, Argentina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
José Luis Scapellato
Intensive Care Unit, Anchorena Hospital, Buenos Aires City, Buenos Aires, Argentina.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND: We sought to evaluate the performance in terms of absolute humidity (AH), relative humidity (RH), and temperature of different heated humidifiers (HH) and circuits that are commonly used to deliver high-flow oxygen therapy in conventional ranges (30–60 L/min) and unconventional ranges (70–100 L/min).

METHODS: In this prospective, observational study, an electronic thermohygrometer was used to obtain the required measurements. A mechanical ventilator was used as a source for high-flow nasal cannula oxygen therapy. For active humidification, the following equipment was used: a HH with standard disposable water trap circuit, 3 servo-controlled HH, and 7 circuits with a heated wire. Data on environmental conditions (ie, temperature, RH, AH) were collected from the laboratory during each measurement; the temperature, RH, and AH resulting from the application of 8 flows (30–100 L/min) were also recorded. Variables were compared with analysis of variance for repeated measurements with Tukey post hoc tests. A value of P < .05 was assumed to be significant.

RESULTS: During the study, a statistically significant difference was found in the average AH for each flow for the different devices (P < .005). The highest AH values were recorded with the Fisher & Paykel MR850 and the Medtronic-DAR circuit (AH = 40.8 mg/L with flow of 50 L/min, P < .005), and the lowest AH values were recorded with the Flexicare FL9000 HH and the Flexicare circuit (AH = 11.4 mg/L with 100 L/min flow, P < .005). For flows > 50 L/min, the best performance for all flows in terms of AH was found with the Fisher & Paykel MR850 HH, regardless of the circuit used.

CONCLUSIONS: During oxygen therapy with very high gas flows, HH devices behave differently and in many cases are inefficient in delivering adequate humidification, even at conventional flows. Caution is therefore recommended when selecting the device and flow settings for the implementation of high-flow nasal cannula oxygen therapy.

  • high-flow oxygen therapy
  • active humidification
  • oxygen
  • intensive care unit

Introduction

High-flow nasal cannula (HFNC) oxygen therapy allows humidified oxygen to be delivered at high flows (up to 60 L/min) by controlling Embedded Image.1,2 The use of HFNC in ICUs has increased due to the benefit it has shown in the treatment of certain pathologies. There is currently sufficient evidence to support the implementation of HFNC in patients with acute hypoxemic respiratory failure3 as well as for the prevention of re-intubation of low-risk patients.4

Although the mechanisms by which this therapy is effective are still under debate, we know that the use of high flows of up to 60 L/min washes out carbon dioxide5 from the upper airway, delivers some level of positive pressure,6,7 and consequently has some effect on end-expiratory lung volume.8,9 In 2015, a study reported that flows of up to 100 L/min result in an increase in pharyngeal airway pressure of 1 cm H2O for every 10 L/min flow. Therefore, therapy with very high gas flows (ie, > 60 L/min) could have a higher beneficial effect (ie, as flow increases, breathing frequency decreases).10 However, flows > 60 L/min could be poorly tolerated by patients, and therefore using very high flows might not be clinically relevant.

Regarding the devices that condition gas for administration through HFNC, few studies have evaluated performance in terms of the temperature and humidity delivered. In these studies, 2 commercial brands of equipment are compared with their respective heater-wire circuits, and only in one of these studies is high gas flow evaluated, with 90 L/min being the maximum flow evaluated.11,12

The objective of this study was to evaluate the performance of different brands of heated humidifiers (HH) and circuits, in terms of absolute humidity (AH), relative humidity (RH), and temperature, during the use of HFNC at conventional (ie, 30–60 L/min) and unconventional (ie, 70–100 L/min) flow ranges.

QUICK LOOK

Current knowledge

The use of the heated humidifiers and circuits during high-flow nasal cannula oxygen therapy is recommended to optimize the humidity delivered and to improve patient comfort and compliance.

What this paper contributes to our knowledge

Heated humidifiers and circuits behaved differently during high-flow oxygen therapy, and in many cases they were inefficient in delivering adequate humidification even at conventional flows (< 60 L/min). This can negatively affect patient comfort and treatment tolerance, and it could impair the function of ciliary epithelium and clearance of secretions.

Methods

We performed this prospective observational study in the Sanatorio Anchorena equipment analysis laboratory between June 5 and July 20, 2019. To obtain humidity measurements, an electronic thermohygrometer (605-H1, Testo, West Chester, Pennsylvania) was used (temperature range: 0–50°C, accuracy ± 0.5°C; humidity accuracy up to 95%). A microprocessor-controlled ventilator device (Savina 300, Dräger, Lübeck, Germany) was used to deliver HFNC. For active humidification, the following equipment was tested: a Cloud HH (MARK SRL, La Plata, Argentina) with a standard disposable water trap circuit, 3 servo-controlled HHs (Fisher & Paykel MR850, Auckland, New Zealand; FL9000, Flexicare, Mountain Ash, Wales; AquaVENT, Armstrong, Coleraine, Ireland), and 7 circuits with a heater-wire (RT202, Fisher & Paykel; Evaqua 2, Fisher & Paykel; Medtronic-DAR, Mirandola, Italy; Flexicare; Intersurgical, Wokingham, United Kingdom; AquaVENT; GGM, Changhua, Taiwan). Environmental temperature, RH, and AH were collected from the laboratory during each measurement, and the temperature, RH, and AH resulting from the application of each of the flows were recorded at the distal end of the circuit (Fig. 1).

Fig. 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.

Assembly and measurement: (A) Mechanical ventilator to generate oxygen therapy at high flows (Savina 300, Dräger); (B) servo-controlled heated humidifier; (C) heater-wire circuit; (D) thermohygrometer (Testo 605-H1).

Measurement Procedure

The Cloud HH was evaluated with the highest device temperature level (ie, level 9) and the servo-controlled HH in noninvasive mode. The 7 heater-wire circuits were randomly combined with each device, and each combination was evaluated with flows of 30, 40, 50, 60, 70, 80, 90, and 100 L/min following a random sequence generated online (https://www.randomization.com). During the study, recordings of 22 flow sequences were performed. Each was composed of 9 sets of temperature, RH, and AH measurements (ie, of the environment and of each of the 8 flows). The protocol for the measurements during the study was is described as follows:

  1. Fill the chambers with distilled water with sufficient volume for the entire duration of testing.

  2. Turn on the HH in noninvasive mode for servo-controlled HH, or at level 9 for the Cloud HH and attached circuits. Turn the device on (no flow, and the housing filled with distilled water) and allow 5 min for device stabilization.

  3. Record the environmental laboratory measurements (temperature, RH and AH) at the end of the initial 5 min of stabilization.

  4. Activate the ventilator flow at 20 L/min for 5 min.

  5. After 5 min of flow at 20 L/min, set the ventilator the flow for the initial measurement according to the randomization sequence. Allow the device to stabilize for 10 min at each of the programmed flows before taking the measurements.

  6. Measurements consisted of a series of 3 recordings over 3 min (1 per minute). In each minute, temperature, RH, and a calculation of the AH corresponding to that measurement were recorded.

  7. Although the system reached its stabilization in 1 min, to avoid the influence of one measurement on the next one, we allowed a period of 3 min between each measurement (ie, zero movement).

  8. At the end of the complete measurement sequence, which required 2 h, the presence or absence of condensation in the circuits was noted (ie, yes or no).

Statistical Analysis

Continuous data were expressed as mean ± SD or as median and interquartile range according to their frequency distribution. Normality was assessed by visual inspection and with the Shapiro-Wilk test. Categorical data were expressed as absolute values or percentages. Variables were compared using analysis of variance for repeated measurements. We performed a marginal model analysis. After testing the model with different covariance structures, we selected the best one according to the Akaike information criterion. For multiple comparison, we used the Tukey post hoc test. A value of P < .05 was considered significant. For statistical analysis, we used SPSS 25.0 (IBM, Armonk, New York).

Results

The average environmental temperature of the laboratory was 21.6 ± 1.2°C, with an RH of 44.8 ± 3.5% and an AH of 8 ± 2.4 mg/L. During the study, a statistically significant difference was noted in the average AH for each flow between the different combinations of devices and circuits (P < .001) (Table 1 and Table 2).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1.

Temperature, Relative Humidity, and Absolute Humidity for Different Devices and Circuits at Conventional Flows of 30–60 L/min

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 2.

Temperature, Relative Humidity, and Absolute Humidity for Different Devices and Circuits at Unconventional Flows of 70–100 L/min

The highest AH values were recorded with the Fisher & Paykel MR850 active humidifier and the Medtronic-DAR circuit (AH = 40.8 mg/L with flow of 50 L/min, P < .001). The lowest AH was recorded with the HH and the Flexicare FL9000 circuit (AH = 11.4 mg/L with 100 L/min flow, P < .001) (Fig. 2).

Fig. 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.

Absolute humidity delivered by the different combinations of devices and circuits at different flows. HH1: Cloud heated humidifier; HH2: Fisher & Paykel MR850 Heated Humidifier; HH3: Flexicare FL9000 heated humidifier; HH4: AquaVENT Armstrong heated humidifier; CircTA: conventional disposable circuit with water trap; Circ1: Fisher & Paykel RT202 heater-wire circuit; Circ2: Fisher & Paykel Evaqua 2 heater-wire circuit; Circ3: Medtronic-DAR heater-wire circuit; Circ4: Flexicare heater-wire circuit; Circ5: Intersurgical heater-wire circuit; Circ6: AquaVENT heater-wire circuit; Circ7: GGM heater-wire circuit.

The lowest overall performance among the different combinations was observed with the Flexicare FL9000 HH combined with the same brand heater-wire circuit, with a maximum AH of 14.5 mg/L at a flow of 30 L/min and decreasing significantly with higher flows (P < .001). In contrast, the Fisher & Paykel MR850 HH combined with the Fisher & Paykel Evaqua 2 circuit always delivered AH > 33 mg/L, even with flows of 100 L/min. For flows > 50 L/min, the best performance for all flows in terms of AH was with the Fisher & Paykel MR850 HH, regardless of the circuit used (P < .001) (Fig. 3).

Fig. 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 3.

Absolute humidity delivered at different flows in relation to the different combinations of devices and circuits. HH1: Cloud heated humidifier; HH2: Fisher & Paykel MR850 Heated Humidifier; HH3: Flexicare FL9000 heated humidifier; HH4: AquaVENT Armstrong heated humidifier; CircTA: conventional disposable circuit with water trap; Circ1: Fisher & Paykel RT202 heater-wire circuit; Circ2: Fisher & Paykel Evaqua 2 heater-wire circuit; Circ3: Medtronic-DAR heater-wire circuit; Circ4: Flexicare heater-wire circuit; Circ5: Intersurgical heater-wire circuit; Circ6: AquaVENT heater-wire circuit; Circ7: GGM heater-wire circuit.

Regarding the presence of condensation in the circuits, this was observed when using the Cloud HH with the disposable circuit with water trap and when using the Fisher & Paykel MR850 HH with all of the heater-wire circuits except the Medtronic-DAR circuit. The Medtronic-DAR circuit was the only one in which no condensation was observed independently of the HH used (Table 3).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 3.

Presence of Condensation With Different Combinations of Humidifiers and Heated Circuits

Discussion

This study provides information on the performance of currently available HH systems used for HFNC, in terms of temperature and humidity delivered. To our knowledge, this is the first study to evaluate flows of up to 100 L/min. We consider it important to evaluate unconventional flow ranges because, although these flows may be poorly tolerated by patients and there is still no evidence of proven benefit, some new mechanical ventilators incorporate them as a possibility within the range of available flow. When comparing the 22 sequences, a statistically significant difference was found in the average of AH for each flow between the different combinations of devices and circuits, and even in several cases less than the minimum recommended for mechanical ventilation (ie, 33 mg/L).13 While using high-flow gas through a nasal cannula, gas flow passes through the upper airway. Therefore, the heating and humidification function is preserved, so that the gas is inspired at 31°C and is fully saturated with water vapor (ie, 100% RH), which should prevent airway dryness and associated lesions. Hence, starting the HFNC at a lower temperature may be a reasonable clinical approach to take advantage of positive clinical outcomes derived from higher comfort, improved tolerance, and longer application of the noninvasive support.14

The best-performing HH in terms of AH exceeded the recommended lower limit with 6 of the 7 circuits used at all evaluated flows. The rest of the HHs, regardless of the flow used, did not reach this minimum value of AH delivered with any of the circuits used.13 The HH with the lowest performance was far from reaching the recommended AH, in addition to exhibiting significant decreases in performance with increasing flow. The latter, in addition to negatively affecting patient comfort, could impair the function of ciliary epithelium and clearance of secretions, even causing some retention of secretions.15,16

In general, the combinations evaluated at the different flows implemented kept the delivery of the temperature stable but not the RH, which could be attributed to 2 phenomena. First, the circuit used could have influenced the RH because the HH managed to keep the temperature stable and thus allowed variation in the RH, and therefore the AH could be due to technical issues related to the circuit. Second, the shorter contact time of the gas with the air-liquid interface of the HH chamber as a result of increasing the flow undoubtedly affects the performance of the device. A way to mitigate this effect, besides the method proposed by Chikata et al,12 could be to increase the contact surface with the use of 2 HHs in series, which, although achievable, could be costly and impractical to implement.

In addition to being the best performer, the combination of the Fisher & Paykel MR850 HH with the Medtronic-DAR circuit was the only setup in which no condensation was recorded during the study. This could be due to the fact that the DAR circuit has a different design from the others, whereby the heater-wire uniformly surrounds the outside of the pipe as an integrated spiral wire, minimizing the influence of the environmental temperature on the flow of gas. Throughout this study, an average environmental temperature of 21.6°C was recorded. According to Chikata et al,17 at conventional flows (ie, < 60 L/min), the environmental temperature has an influence on the amount of condensation recorded in the circuits, with condensation being significantly greater at 20°C compared to a temperature of 25°C. It should be noted that we only noted condensation with the Fisher & Paykel MR850 HH, probably because it was the device that delivered higher values of temperature and humidity. This characteristic, in combination with circuits with less thermal isolation, could result in condensation even at an unconventional flow (eg, > 60 L/min).

This study has certain limitations, the main one being the fact that it is a laboratory study, so the results obtained must be interpreted with caution in a clinical setting. In addition, although the study was designed to evaluate the performance of devices at different flow levels, a simulation of different ventilation patterns and tidal volume was not performed, so we could not assess their influence on the performance of humidification systems, although there is evidence that invasive mechanical ventilation might not affect the delivery of AH.18 Also, the use of an Embedded Image of 0.21 could be questioned. However, from the point of view of thermodynamic characteristics (eg, specific heat, molecular weight, density), both compressed air and oxygen, and their mixture, have similar behavior.19 Finally, flows > 60 L/min aren't currently used in clinical practice, so our results should be interpreted with caution in a clinical setting. More studies are needed to evaluate its usefulness in a clinical scenario.

Conclusions

During HFNC oxygen therapy at conventional and unconventional flow ranges, heated humidifiers behave differently, in many cases being inefficient in delivering adequate humidification, even at conventional flows. Caution is therefore recommended when selecting the devices and flows for the implementation of high-flow oxygen therapy.

Footnotes

  • Correspondence: Gustavo A Plotnikow PT, 1872 Tomás M. de Anchorena Street, 1425, Buenos Aires City, Argentina. E-mail: gplotnikow{at}gmail.com
  • The authors have disclosed no conflicts of interest.

  • Mr Villalba presented a version of this paper at the 49th Argentinian Conference of Respiratory Medicine, held October 31, 2019, in Rosario, Argentina.

  • Copyright © 2020 by Daedalus Enterprises

References

  1. 1.↵
    1. Roca O,
    2. Hernández G,
    3. Díaz-Lobato S,
    4. Carratalá JM,
    5. Gutiérrez RM,
    6. Masclans JR
    , Spanish Multidisciplinary Group of High Flow Supportive Therapy in Adults (HiSpaFlow). Current evidence for the effectiveness of heated and humidified high-flow nasal cannula supportive therapy in adult patients with respiratory failure. Crit Care 2016;20(1):109.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Nishimura M
    . High-flow nasal cannula oxygen therapy devices. Respir Care 2019;64(6):735–742.
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    1. Frat J-P,
    2. Thille AW,
    3. Mercat A,
    4. Girault C,
    5. Ragot S,
    6. Perbet S,
    7. et al
    . High-flow oxygen through nasal cannula in acute hypoxemic respiratory failure. N Engl J Med 2015;372(23):2185–2196.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Hernández G,
    2. Vaquero C,
    3. González P,
    4. Subira C,
    5. Frutos-Vivar F,
    6. Rialp G,
    7. et al
    . Effect of postextubation high-flow nasal cannula vs. conventional oxygen therapy on reintubation in low-risk patients a randomized clinical trial. JAMA 2016;315(13):1354–1361.
    OpenUrl
  5. 5.↵
    1. Onodera Y,
    2. Akimoto R,
    3. Suzuki H,
    4. Okada M,
    5. Nakane M,
    6. Kawamae K
    . A high-flow nasal cannula system with relatively low flow effectively washes out CO2 from the anatomical dead space in a sophisticated respiratory model made by a 3D printer. Intensive Care Med Exp 2018;6(1):7.
    OpenUrl
  6. 6.↵
    1. Groves N,
    2. Tobin A
    . High-flow nasal oxygen generates positive airway pressure in adult volunteers. Aust Crit Care 2007;20(4):126–131.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Parke RL,
    2. Eccleston ML,
    3. McGuinness SP
    . The effects of flow on airway pressure during nasal high-flow oxygen therapy. Respir Care 2011;56(8):1151–1155.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Plotnikow GA,
    2. Thille AW,
    3. Vasquez DN,
    4. Pratto RA,
    5. Quiroga CM,
    6. Andrich ME,
    7. et al
    . Effects of high-flow nasal cannula on end-expiratory lung impedance in semi-seated healthy subjects. Respir Care 2018;63(8):1016–1023.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Riera J,
    2. Pérez P,
    3. Cortés J,
    4. Roca O,
    5. Masclans JR,
    6. Rello J
    . Effect of high-flow nasal cannula and body position on end-expiratory lung volume: a cohort study using electrical impedance tomography. Respir Care 2013;58(4):589–596.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Parke RL,
    2. Bloch A,
    3. McGuinness SP
    . Effect of very high-flow nasal therapy on airway pressure and end-expiratory lung impedance in healthy volunteers. Respir Care 2015;60(10):1397–1403.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. Chikata Y,
    2. Izawa M,
    3. Okuda N,
    4. Itagaki T,
    5. Nakataki E,
    6. Onodera M,
    7. et al
    . Humidification performance of two high-flow nasal cannula devices: a bench study. Respir Care 2014;59(8):1186–1190.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    1. Chikata Y,
    2. Morinishi K,
    3. Nishimura M
    . Humidification in very-high-flow nasal-cannula therapy in an adult lung model. Respir Care 2019;64(7):809–817.
    OpenUrlAbstract/FREE Full Text
  13. 13.↵
    1. Restrepo RD,
    2. Walsh BK
    , American Association for Respiratory Care. Humidification during invasive and noninvasive mechanical ventilation: 2012. Respir Care 2012;57(5):782–788.
    OpenUrlAbstract/FREE Full Text
  14. 14.↵
    1. Mauri T,
    2. Galazzi A,
    3. Binda F,
    4. Masciopinto L,
    5. Corcione N,
    6. Carlesso E,
    7. et al
    . Impact of flow and temperature on patient comfort during respiratory support by high-flow nasal cannula. Crit Care 2018;22(1):120.
    OpenUrl
  15. 15.↵
    1. Sottiaux TM
    . Consequences of under- and over-humidification. Respir Care Clin N Am 2006;12(2):233–252.
    OpenUrlPubMed
  16. 16.↵
    1. Gross JL,
    2. Park GR
    . Humidification of inspired gases during mechanical ventilation. Minerva Anestesiol 2012;78(4):496–502.
    OpenUrlPubMed
  17. 17.↵
    1. Chikata Y,
    2. Unai K,
    3. Izawa M,
    4. Okuda N,
    5. Oto J,
    6. Nishimura M
    . Inspiratory tube condensation during high-flow nasal cannula therapy: a bench study. Respir Care 2016;61(3):300–305.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Lellouche F,
    2. Qader S,
    3. Taillé S,
    4. Lyazidi A,
    5. Brochard L
    . Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers. Respir Care 2014;59(5):637–643.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. Züchner K
    . Humidification: measurement and requirements. Respir Care Clin N Am 2006;12(2):149–163.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

Respiratory Care: 65 (9)
Respiratory Care
Vol. 65, Issue 9
1 Sep 2020
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author

 

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Association for Respiratory Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Performance of Different Active Humidification Systems in High-Flow Oxygen Therapy
(Your Name) has sent you a message from American Association for Respiratory Care
(Your Name) thought you would like to see the American Association for Respiratory Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Performance of Different Active Humidification Systems in High-Flow Oxygen Therapy
Gustavo A Plotnikow, Darío Villalba, Emiliano Gogniat, Corina Quiroga, Eliana Pérez Calvo, José Luis Scapellato
Respiratory Care Sep 2020, 65 (9) 1250-1257; DOI: 10.4187/respcare.07654

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Performance of Different Active Humidification Systems in High-Flow Oxygen Therapy
Gustavo A Plotnikow, Darío Villalba, Emiliano Gogniat, Corina Quiroga, Eliana Pérez Calvo, José Luis Scapellato
Respiratory Care Sep 2020, 65 (9) 1250-1257; DOI: 10.4187/respcare.07654
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

Cited By...

Keywords

  • high-flow oxygen therapy
  • active humidification
  • oxygen
  • intensive care unit

Info For

  • Subscribers
  • Institutions
  • Advertisers

About Us

  • About the Journal
  • Editorial Board

AARC

  • Membership
  • Meetings
  • Clinical Practice Guidelines

More

  • Contact Us
  • RSS
American Association for Respiratory Care

Print ISSN: 0020-1324        Online ISSN: 1943-3654

© Daedalus Enterprises, Inc.

Powered by HighWire