RT Journal Article SR Electronic T1 Targeted Lung Deposition From Nebulization Is Not Improved in the Lateral Decubitus Position in Healthy Volunteers JF Respiratory Care FD American Association for Respiratory Care SP 1537 OP 1544 DO 10.4187/respcare.06978 VO 64 IS 12 A1 Gregory Reychler A1 Marta San Miguel-Pagola A1 Anne-Sophie Aubriot A1 Beatriz Herrero-Cortina A1 Vinciane Lecocq A1 Michel Hesse A1 Giuseppe Liistro A1 François Jamar YR 2019 UL http://rc.rcjournal.com/content/64/12/1537.abstract AB BACKGROUND: Clinical benefits of inhaled therapies are related to the amount of drug deposited in the targeted area of the lung. Body positions that influence the distribution of lung ventilation should impact lung deposition of the nebulized drug. The aim of this study was to analyze the immediate effect of body position while the subject lies on his side (lateral decubitus) during nebulization on 3-dimensional total and regional lung deposition.METHODS: A randomized crossover trial was performed on healthy male volunteers without cardiovascular or pulmonary disease. A technetium-99m diethylenetriaminepentaacetic acid (99mTc-DTPA) solution (4 mL) was nebulized using an individual-controlled inhalation system in left lateral decubitus and sitting positions with a 96-h washout period (43 inspirations of 4 s [ie, drug delivered until second 3] with a tidal volume of 0.8 L and a low inspiratory flow (200 mL/s). Drug deposition was followed with the use of planar images and single-photon-emission computed tomography combined with low-resolution computed tomography. Total and regional depositions were the main outcomes. Penetration index was also considered.RESULTS: Six participants (26.8 ± 6.9 y old) were included. Total lung deposition tended to be higher in a sitting position than in a lateral decubitus position: 10.2 ± 0.9% of nominal dose (95% CI 9.1–11.3) vs 8.6 ± 1.4% of nominal dose (95% CI 6.8–10.4) (P = .09). The deposition was significantly reduced in the dependent (left) lung in the lateral decubitus position: 3.5 ± 0.7% of nominal dose (95% CI 2.6–4.3) vs 4.7 ± 0.3% of nominal dose (95% CI 4.3–5.0) (P = .03). Penetration index was only influenced by body position for the dependent (left) lung (P = .043).CONCLUSIONS: The total amount of drug delivered to the lungs during nebulization with an individual-controlled inhalation system tended to decrease when performed in the left lateral decubitus position. Moreover, contrary to the initial hypothesis, the deposition of particles in the dependent lung was not improved by the lateral decubitus position in this configuration. (ClinicalTrials.gov registration NCT02451501.)