RT Journal Article SR Electronic T1 COVID-19 ARDS Is Characterized by Increased Dead Space Ventilation Compared With Non-COVID ARDS JF Respiratory Care FD American Association for Respiratory Care SP 1406 OP 1415 DO 10.4187/respcare.08786 VO 66 IS 9 A1 Michele Bertelli A1 Federica Fusina A1 Chiara Prezioso A1 Erika Cavallo A1 Niccolò Nencini A1 Serena Crisci A1 Francesca Tansini A1 Letizia Mazzuca Mari A1 Laureta Hoxha A1 Fabiana Lombardi A1 Giuseppe Natalini YR 2021 UL http://rc.rcjournal.com/content/66/9/1406.abstract AB BACKGROUND: ARDS in patients with coronavirus disease 2019 (COVID-19) is characterized by microcirculatory alterations in the pulmonary vascular bed, which could increase dead-space ventilation more than in non-COVID-19 ARDS. We aimed to establish if dead-space ventilation is different in patients with COVID-19 ARDS when compared with patients with non-COVID-19 ARDS.METHODS: A total of 187 subjects with COVID-19 ARDS and 178 subjects with non-COVID-19 ARDS who were undergoing invasive mechanical ventilation were included in the study. The association between the ARDS types and dead-space ventilation, compliance of the respiratory system, subjects’ characteristics, organ failures, and mechanical ventilation was evaluated by using data collected in the first 24 h of mechanical ventilation.RESULTS: Corrected minute ventilation (V˙E), a dead-space ventilation surrogate, was higher in the subjects with COVID-19 ARDS versus in those with non-COVID-19 ARDS (median [interquartile range] 12.6 [10.2-15.8] L/min vs 9.4 [7.5-11.6] L/min; P < .001). Increased corrected V˙E was independently associated with COVID-19 ARDS (odds ratio 1.24, 95% CI 1.07-1.47; P = .007). The best compliance of the respiratory system, obtained after testing different PEEPs, was similar between the subjects with COVID-19 ARDS and the subjects with non-COVID-19 ARDS (mean ± SD 38 ± 11 mL/cm H2O vs 37 ± 11 mL/cm H2O, respectively; P = .61). The subjects with COVID-19 ARDS received higher median (interquartile range) PEEP (12 [10-14] cm H2O vs 8 [5-9] cm H2O; P < .001) and lower median (interquartile range) tidal volume (5.8 [5.5-6.3] mL/kg vs 6.6 [6.1-7.3] mL/kg; P < .001) than the subjects with non-COVID-19 ARDS, being these differences maintained at multivariable analysis. In the multivariable analysis, the subjects with COVID-19 ARDS showed a lower risk of anamnestic arterial hypertension (odds ratio 0.18, 95% CI 0.07-0.45; P < .001) and lower neurologic sequential organ failure assessment score (odds ratio 0.16, 95% CI 0.09-0.27; P < .001) than the subjects with non-COVID-19 ARDS.CONCLUSIONS: Indirect measurements of dead space were higher in subjects with COVID-19 ARDS compared with subjects with non-COVID-19 ARDS. The best compliance of the respiratory system was similar in both ARDS forms provided that different PEEPs were applied. A wide range of compliance is present in every ARDS type; therefore, the setting of mechanical ventilation should be individualized patient by patient and not based on the etiology of ARDS.