TY - JOUR T1 - Contemporary Ventilator Management in Patients With and at Risk of ALI/ARDS JF - Respiratory Care SP - 578 LP - 588 DO - 10.4187/respcare.01755 VL - 58 IS - 4 AU - Steven Y Chang AU - Ousama Dabbagh AU - Ognen Gajic AU - Amee Patrawalla AU - Marie-Carmelle Elie AU - Daniel S Talmor AU - Atul Malhotra AU - Adebola Adesanya AU - Harry L Anderson III AU - James M Blum AU - Pauline K Park AU - Michelle Ng Gong AU - on behalf of the United States Critical Illness and Injury Trials Group: Lung Injury Prevention Study Investigators (USCIITG-LIPS) Y1 - 2013/04/01 UR - http://rc.rcjournal.com/content/58/4/578.abstract N2 - See the complete list of Lung Injury Prevention Study Investigators members below. BACKGROUND: Ventilator practices in patients at risk for acute lung injury (ALI) and ARDS are unclear. We examined factors associated with choice of set tidal volumes (VT), and whether VT < 8 mL/kg predicted body weight (PBW) relates to the development of ALI/ARDS. METHODS: We performed a secondary analysis of a multicenter cohort of adult subjects at risk of lung injury with and without ALI/ARDS at onset of invasive ventilation. Descriptive statistics were used to describe ventilator practices in specific settings and ALI/ARDS risk groups. Logistic regression analysis was used to determine the factors associated with the use of VT < 8 mL/kg PBW and the relationship of VT to ALI/ARDS development and outcome. RESULTS: Of 829 mechanically ventilated patients, 107 met the criteria for ALI/ARDS at time of intubation, and 161 developed ALI/ARDS after intubation (post-intubation ALI/ARDS). There was significant intercenter variability in initial ventilator settings, and in the incidence of ALI/ARDS and post-intubation ALI/ARDS. The median VT was 7.96 (IQR 7.14–8.94) mL/kg PBW in ALI/ARDS subjects, and 8.45 (IQR 7.50–9.55) mL/kg PBW in subjects without ALI/ARDS (P = .004). VT decreased from 8.40 (IQR 7.38–9.37) mL/kg PBW to 7.97 (IQR 6.90–9.23) mL/kg PBW (P < .001) in those developing post-intubation ALI/ARDS. Among subjects without ALI/ARDS, VT ≥ 8 mL/kg PBW was associated with shorter height and higher body mass index, while subjects with pneumonia were less likely to get ≥ 8 mL/kg PBW. Initial VT ≥ 8 mL/kg PBW was not associated with the post-intubation ALI/ARDS (adjusted odds ratio 1.30, 95% CI 0.74–2.29) or worse outcomes. Post-intubation ALI/ARDS subjects had mortality similar to subjects intubated with ALI/ARDS. CONCLUSIONS: Clinicians seem to respond to ALI/ARDS with lower initial VT. Initial VT, however, was not associated with the development of post-intubation ALI/ARDS or other outcomes. (ClinicalTrials.gov registration NCT00889772) ER -