Oxygen consumption in infants and children during heart catheterization

  • Original Articles
  • Published:
Pediatric Cardiology Aims and scope Submit manuscript

Abstract

Oxygen consumption was measured in infants, children, and adolescents during diagnostic heart catheterizations. A total of 825 measurements of oxygen consumption (VO2) was performed in 504 subjects using a semiopen hood system and a paramagnetic oxygen analyzer. In 256 subjects under 3 years of age, body dimensions and heart rate were found to be significant factors for oxygen consumption. The regression equation for both sexes was: VO2/BSA (ml/min·m2)=3.42·height (cm)−7.83·weight (kg) +0.38·HR −54.1 (r 2=0.39, SD=38.7), where BSA is body surface area and HR is heart rate. VO2/BSA was significantly lower in infants less than 3 months of age (133±33 ml/min·m2 compared with infants of 3–12 months (171±37 ml/min·m2;p<0.01). In 272 children aged 3 years and older and adolescents, gender was a significant factor in oxygen consumption together with BSA and HR. The regression line equation for males was VO2/BSA (ml/min·m2)=0.79·HR−7.4·BSA(m2+108.1 (r 2=0.45, SD=34.2). The regression line equation for females is VO2/BSA (ml/min·m2)=0.77·HR−5.2·BSA(m2)+106.8 (r 2=0.43, SD=34.4). Hematocrit, systemic oxygen saturation, and blood pressure were not significant factors. The predictive value of nomograms for oxygen consumption is limited because of the large interindividual variations not explained by differences in gender, body size, or simple hemodynamic variables. Preferably, oxygen consumption is measured; but if nomograms for oxygen consumption are used for hemodynamic assessment, the wide confidence intervals should be considered.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Baum D, Baum AC, Church SC (1967) Effect of sedation on oxygen consumption of children undergoing cardiac catheterization.Pediatrics 39:891–895

    PubMed  CAS  Google Scholar 

  2. Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement.Lancet 8476:307–310

    Google Scholar 

  3. Brodin LA (1987) Nuclear ejection fraction measurements with a small crystal detector: Methodology investigations.Clin Physiol 7:217–219

    PubMed  CAS  Google Scholar 

  4. Du Bois D, Du Bois EF (1916) Clinical calorimetry: A formula to estimate the approximate surface area if height and weight be known.Arch Intern Med 17:863–871

    Google Scholar 

  5. Fick A (1870) Über die Messung des Blutquantums in der Herzventrikeln.Sitzungsberichte der physikalisch-medicinischen Gesellschaft zu Wurtzberg XVI–XVII

  6. Fixler DE, Carrell T, Browne R, Willis K, Miller WW (1974) Oxygen consumption in infants and children during cardiac catheterization under different sedation regimens.Circulation 50:788–794

    PubMed  CAS  Google Scholar 

  7. Freed MD, Keane JF (1978) Cardiac output by thermodilution in infants and children.J Pediatr 92:39–42

    Article  PubMed  CAS  Google Scholar 

  8. Ihlen H, Amlie J, Dale J, et al (1984) Determination of cardiac output by Doppler echocardiography.Br Heart J 51:54–60

    PubMed  CAS  Google Scholar 

  9. Kappagoda CT, Greenwood P, Macartney FJ, Linden RJ (1973) Oxygen consumption in children with congenital diseases of the heart.Clin Sci 45:107–114

    PubMed  CAS  Google Scholar 

  10. La Farge CG, Miettinen OS (1970) The estimation of oxygen consumption.Cardiovasc Res 4:23–30

    Google Scholar 

  11. Mocellin R, Muhlstein V, Buhlmeyer K (1980) Der Sauerstoffverbrauch von herzkranken Säuglingen und Kindern.Hertz 5:385–392

    Google Scholar 

  12. Northridge DB, Findlay IN, Wilson J, Henderson E, Dargie HJ (1990) Noninvasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.Br Heart J 63:93–97

    PubMed  CAS  Google Scholar 

  13. Powner DJ, Snyder JV (1978) In vitro comparison of six commercially available thermodilution cardiac output systems.Med Instrum 12: 122–127

    PubMed  CAS  Google Scholar 

  14. Rudolph AM, Cayler GG (1958) Cardiac catheterization in infants and children.Pediatr Clin North Am 5:907–943

    PubMed  CAS  Google Scholar 

  15. Schuster AH, Nanda NC (1984) Doppler echocardiographic measurement of cardiac output: comparison with a non-golden standard.Am J Cardiol 53:257–259

    Article  PubMed  CAS  Google Scholar 

  16. Seitz WS, McIlroy MB (1988) Interpretation of the HJ interval of the normal ballistocardiogram based on the principle of conservation of momentum and aortic ultrasonic doppler velocity measurements during left ventricular ejection.Cardiovasc Res 22: 571–574

    Article  PubMed  CAS  Google Scholar 

  17. Sheperd JT, Bowers D, Wood EH (1955) Measurement of cardiac output in man by injection of dye at constant rate into the right ventricle or pulmonary artery.J Appl Physiol 7:629

    Google Scholar 

  18. Starr I (1941) Clinical studies with the ballistocardiograph in congestive failure, on digitalis action, on changes in ballistic form, and in certain acute experiments.Am J Med Sci 202:469

    Article  Google Scholar 

  19. Tanner JM (1949) Fallacy of per weight and per surface area standards, and their relation to spurious correlation.J Appl Physiol 2:1–15

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lundell, B.P.W., Casas, M.L. & Wallgren, C.G. Oxygen consumption in infants and children during heart catheterization. Pediatr Cardiol 17, 207–213 (1996). https://doi.org/10.1007/BF02524795

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02524795

Key words

Navigation