Abstract
Objective.Supplemental oxygen treatment of patients on mechanical ventilation is crucial in maintaining the patients’ oxygen levels in the normal range. The purpose of this study was to evaluate the effectiveness of a closed-loop controller for automatic adjustment of the fraction of inspired oxygen, FIO2. More specifically, the aim of the study was to assess the robustness of the controller in correcting hypoxemia as well as its effectiveness in prevention of hyperoxemia and oxygen toxicity. Methods.The microprocessor-based feedback control system combines a rapid control algorithm with a proportional-integral-derivative (PID) control procedure to automatically adjust FIO2. The system is designed to prevent hypoxemia by applying a stepwise control procedure in response to rapid declines in arterial oxygen saturation while fine-tuning FIO2 and avoiding hyperoxemia by resuming to the PID control procedure when appropriate. The system includes a sophisticated safeguard unit which is designed to communicate any oxygenation problems or measurement artifacts to the medical personnel while keeping FIO2 at a safe and sufficiently high level. The control system has been tested by using computer simulations as well as animal studies. Results.In response to different disturbances, the arterial oxygen saturation returned to the normal safe range within less than 20 seconds, thereby avoiding any untoward effects of hypoxemia. Under steady state conditions, the variations in arterial oxygen saturation were kept within ± 3% of the mean value. The controller corrected hypoxemia within seconds while preventing hyperoxemia, rejecting artifacts, and minimizing exposure to high concentrations of oxygen. Conclusion.The results of the study attest to the reliability of the proposed closed-loop control scheme for automatic adjustment of FIO2. Further evaluation of the controller will require testing the effectiveness of the system on different patient groups.
Article PDF
Similar content being viewed by others
REFERENCES
Mitamura Y, Mikami T, Yamamoto K, Mimura K. A dual control system for assisting respiration. Med Biol Eng 1975; 13 (6): 846-854
Beddis IR, Collins P, Levy NM, Godfrey S, Silverman M. A new technique for servo-control of arterial oxygen tension in preterm infants. Arch Dis Child 1979; 54: 278-280
Sano A, Kikucki M. Adaptive control of arterial oxygen pressure of newborn infants under incubator oxygen treatments. Proc IEE 1985; 132 (Pt. D., No. 5): 205-211
Yu C, He WG, So JM, Roy R, Kaufman H, Newell JC. Improvement in arterial oxygen control using multiple model adaptive control procedures. IEEE Trans Biomed Eng 1987; BME-34 (8): 567-574
Morozoff PE, Evans RW. Closed-loop control of SaO2 in the neonate. Biomed Instr Tech 1992; 26: 117-123
Tehrani FT. A microcomputer oxygen control system for ventilatory therapy. Ann Biomed Eng 1992; 20 (5): 547-558
Tehrani FT, Bazar AR. A feedback controller for supplemental oxygen treatment of newborn infants: A simulation study. Med Eng Phys 1994; 16: 329-333
Raemer DB, Ji X, Topulos GP. FIx controller: An instrument to automatically adjust inspired oxygen fraction using feedback control from a pulse oximeter. J Clin Monit 1997; 13: 91-101
Tehrani FT. A control system for oxygen therapy of premature infants. Proc IEEE Eng Med Biol Conf 2001; 23 (2): 2059-2062
Solimano AJ, Smyth JA, Mann TK, Albersheim SG, Lockitch G. Pulse oximetry advantages in infants with bronchopulmonary dysplasia. Pediatrics 1986; 78 (5): 844-849
Fanconi S, Doherty P, Edmond JF, Baker GA, Bohn DJ. Pulse oximetry in pediatric intensive care: Comparison with measured saturations and transcutaneous oxygen tension. J Pediatr 1985; 107 (3): 362-366
Bierman MI, Stein KL, Snyder JV. Pulse oximetry in the postoperative care of cardiac surgical patients: A randomized controlled trial. Chest 1992; 102 (5): 1367-1370
Bongard F, Darryl S. Pulse oximetry and capnography in intensive and transitional care units. West J Med 1992; 156 (1): 57-64
Roizen MF, Schneider B, Austin W, Carter C, Polk S. Pulse oximetry, capnography, and blood gas measurements: Reducing cost and improving the quality of care with technology. J Clin Monit 1993; 9 (4): 237-240
Visser BF. Pulmonary di¡usion of carbon dioxide. Phys Med Biol 1961; 5: 155-166
Riley RL. Gas exchange and transportation. In: Ruch TC, Patton HD, eds. Physiology and biophysics. Philadelphia and London: W. B. Saunders Co., 1966: 761-787
Fincham WF, Tehrani FT. A mathematical model of the human respiratory system. J Biomed Eng 1983; 5: 125-133
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Tehrani, F., Rogers, M., Lo, T. et al. Closed-Loop Control of the Inspired Fraction of Oxygen in Mechanical Ventilation. J Clin Monit Comput 17, 367–376 (2002). https://doi.org/10.1023/A:1024261021473
Issue Date:
DOI: https://doi.org/10.1023/A:1024261021473