Plasma catecholamines and oxygen consumption during weaning from mechanical ventilation

Intensive Care Med. 1991;17(4):199-203. doi: 10.1007/BF01709877.

Abstract

Previous studies on oxygen consumption (VO2) during weaning from mechanical ventilation assumed that an increase in VO2 (delta VO2) reflected oxygen consumption by respiratory muscles (VO2RESP), and proposed delta VO2 as a weaning predictor. We measured VO2 CO2 production (VCO2) and plasma catecholamines in 20 short-term ventilated patients during weaning by SIMV and CPAP. delta VO2 as a percentage of VO2 during spontaneous ventilation (delta VO2%) ranged from 4.8% to 41.5%. VCO2 also increased and correlated with VO2. Plasma adrenaline and noradrenaline increased significantly to levels known to produce considerable increases in metabolic rate. Mean arterial pressure and heart rate concomitantly increased, but spontaneous minute ventilation decreased. Thus, since the increased plasma catecholamines are calorigenic, the assumption that delta VO2 represents VO2RESP is incorrect. Although mean delta VO2% of successfully weaned patients was significantly less than that of failure-to-wean patients, the wide scatter of individual values in the latter group excludes delta VO2% as an accurate weaning predictor.