Ultrasound guidance for radial arterial puncture: a randomized controlled trial

Am J Emerg Med. 2013 May;31(5):810-5. doi: 10.1016/j.ajem.2013.01.029. Epub 2013 Mar 25.

Abstract

STUDY OBJECTIVE AND BACKGROUND: Arterial puncture for blood gas analysis is a frequent procedure and could be difficult in the emergency setting. The aim of the study was to compare ultrasonographically guided arterial radial puncture vs conventional sampling.

Materials and methods: This is a prospective, randomized study. The inclusion criteria are all patients needing arterial blood gas at admission in the emergency unit. The exclusion criteria are the following: Hallen test positive, local sepsis, local trauma, known sever local arteriopathy, refusal of consent by the patient, participation in another study, and cardiac arrest. Patients were randomized into 2 groups: radial arterial puncture obtained through an ultrasonographically guided technique (group 1) or radial arterial puncture by conventional method (group 2). The main objective is the number of attempts after enrollment. The secondary objectives are time to success, patient satisfaction and pain, and physician satisfaction. Immediate complications were collected. Groups were compared with nonparametric analysis.

Results: The data were usable for 72 of 74 patients included. Lung disease (acute exacerbation of chronic obstructive pulmonary disease and pneumonia) at 45% (n = 32) and suspicion of pulmonary embolism in 31% (n = 22) were the most common reasons. Demographics data were comparable in the 2 groups. In group 1, the number of attempts significantly increased (2.35 [1-3] vs 1.66 [1-2] [P = .017]), and the sample was 2.4 times longer (132 seconds [50-200] vs 55 [20-65] [P < .01] by standard method). There was no significant difference in terms of pain (visual analog scale [VAS], 3.6 [2-5] for both groups [P = .743]), patient satisfaction (VAS, 7.2 [5-9] vs 6.8 [5-9] [P = .494]), and physician satisfaction (VAS, 6.0 [3.5-8] vs 6.9 [5-9] [P = .233]). No immediate complications were found in the 2 groups.

Conclusion: Ultrasonographically guided arterial puncture increases the number and duration of implementations. This technique, however, does not alter the patient's pain, the number of immediate complications, or patient and physician satisfaction.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Attitude of Health Personnel
  • Blood Gas Analysis
  • Catheterization, Peripheral / adverse effects
  • Catheterization, Peripheral / methods*
  • Emergency Service, Hospital
  • Female
  • Humans
  • Male
  • Middle Aged
  • Outcome Assessment, Health Care
  • Pain / etiology
  • Patient Satisfaction
  • Prospective Studies
  • Punctures / adverse effects
  • Punctures / methods*
  • Radial Artery / diagnostic imaging*
  • Ultrasonography, Interventional*
  • Young Adult