Low-frequency positive-pressure ventilation with extracorporeal CO2 removal in severe acute respiratory failure

…, F Rossi, G Romagnoli, L Uziel, A Agostoni, T Kolobow… - Jama, 1986 - jamanetwork.com
Forty-three patients were entered in an uncontrolled study designed to evaluate extracorporeal
membrane lung support in severe acute respiratory failure of parenchymal origin. Most of …

Severe impairment in lung function induced by high peak airway pressure during mechanical ventilation: an experimental study

T Kolobow, MP Moretti, R Fumagalli… - American Review of …, 1987 - atsjournals.org
We explored the pulmonary effects of continuous mechanical ventilation (MV) at a peak
inspiratory pressure of 50 cm H 2 O in healthy, paralyzed, and anesthetized adult sheep during a …

Histopathologic pulmonary changes from mechanical ventilation at high peak airway pressures

K Tsuno, K Miura, M Takeya, T Kolobow… - Am Rev Respir …, 1991 - atsjournals.org
We investigated the histopathologic pulmonary changes induced by mechanical pulmonary
ventilation (MV) with a high peak airway pressure and a large tidal volume in healthy baby …

Acute lung injury from mechanical ventilation at moderately high airway pressures

K Tsuno, P Prato, T Kolobow - Journal of Applied …, 1990 - journals.physiology.org
We have explored adverse pulmonary effects of mechanical ventilation at a peak inspiratory
pressure of 30 cmH2O in paralyzed and anesthetized healthy sheep. A control group of …

Control of breathing using an extracorporeal membrane lung

T Kolobow, L Gattinoni, TA Tomlinson, JE Pierce - Anesthesiology, 1977 - air.unimi.it
Various amounts of carbon dioxide were removed through an extracorporeal membrane lung
in spontaneously breathing lambs. The decrease in alveolar ventilation was proportional to …

An alternative to breathing

T Kolobow, L Gattinoni, T Tomlinson… - The Journal of thoracic and …, 1978 - Elsevier
If carbon dioxide is removed by an extracorporeal membrane lung ventilated with room air,
the natural lung can be used for oxygen transport alone; we have demonstrated this in lambs …

Construction and evaluation of an alveolar membrane artificial heart-lung

T Kolobow, RL Bowman - ASAIO Journal, 1963 - journals.lww.com
Kolobow, Theodor; Bowman, Robert L. … Articles in PubMed by Theodor Kolobow
Other articles in this journal by Theodor Kolobow

Following tracheal intubation, mucus flow is reversed in the semirecumbent position: Possible role in the pathogenesis of ventilator–associated pneumonia

…, M Cressoni, M Stylianou, T Kolobow - Critical care …, 2008 - journals.lww.com
Objectives: Critically ill intubated patients are positioned in the semirecumbent position to
prevent pneumonia. In tracheally intubated sheep, we investigated the effects of gravitational …

Evaluation of continuous aspiration of subglottic secretion in an in vivo study

…, M Panigada, ZX Yu, A Baccarelli, T Kolobow - Critical care …, 2004 - journals.lww.com
Objective: Continuous aspiration of subglottic secretions (CASS) is believed to lower the
incidence of ventilator-associated pneumonia. Animal studies to establish safety and efficacy of …

A clinical assessment of the Mucus Shaver: a device to keep the endotracheal tube free from secretions

L Berra, A Coppadoro, EA Bittner, T Kolobow… - Critical care …, 2012 - journals.lww.com
… At the end of 2003, Kolobow ( 9 ) designed and fabricated the Mucus Shaver in a laboratory
at the National Institutes of Health, Bethesda, Maryland. Previous studies from his laboratory …