Research ArticleOriginal Research
Use of Maximum End-Tidal CO2 Values to Improve End-Tidal CO2 Monitoring Accuracy
Fabrice Galia, Serge Brimioulle, Frederic Bonnier, Nicolas Vandenbergen, Michel Dojat, Jean-Louis Vincent and Laurent J Brochard
Respiratory Care March 2011, 56 (3) 278-283; DOI: https://doi.org/10.4187/respcare.00837
Fabrice Galia
Réanimation Médicale, l'Assistance Publique-Hôpitaux de Paris, Hôpital Henri Mondor, and with Institut National de la Santé et de la Recherche Médicale (INSERM), Créteil, France.
PhDSerge Brimioulle
Department of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium.
MD PhDFrederic Bonnier
Department of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium.
Nicolas Vandenbergen
Department of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium.
Michel Dojat
INSERM, Université Joseph Fourier, Institut des Neurosciences, Grenoble, France.
PhDJean-Louis Vincent
Department of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium.
MDLaurent J Brochard
Réanimation Médicale, l'Assistance Publique-Hôpitaux de Paris, Hôpital Henri Mondor, and with Institut National de la Santé et de la Recherche Médicale (INSERM), Créteil, France.
Université de Paris Est, Créteil, France, and with Geneva University Hospital, Geneva, Switzerland.
MDReferences
- 1.↵
- Donald MJ,
- Paterson B
- 2.↵
- 3.↵
- 4.↵
- Yamanaka MK,
- Sue DY
- 5.↵
- Dojat M,
- Harf A,
- Touchard D,
- Laforest M,
- Lemaire F,
- Brochard L
- 6.↵
- Lellouche F,
- Mancebo J,
- Jolliet P,
- Roeseler J,
- Schortgen F,
- Dojat M,
- et al
- 7.↵
- Tobin MJ
- Hess D
- 8.↵
- Soltner C,
- Hutzinger J,
- Beydon L
- 9.↵
- Weinger M,
- Brimm J
- 10.↵
- Chopin C,
- Fesard P,
- Mangalaboyi J,
- Lestavel P,
- Chambrin MC,
- Fourrier F,
- et al
- 11.↵
- 12.
- 13.
- Kerr ME,
- Zempsky J,
- Sereika S,
- Orndoff P,
- Rudy EB
- 14.↵
- 15.↵
- Morley TF,
- Giaimo J,
- Maroszan E,
- Bermingham J,
- Gordon R,
- Griesback R,
- et al
- 16.↵
- Blanch L,
- Fernandez R,
- Artigas A
- 17.↵
- Dojat M,
- Harf A,
- Touchard D,
- Lemaire F,
- Brochard L
- 18.
- 19.↵
- Lopez de Mantara R,
- Saitta L
- Mersmann S,
- Dojat M
In this issue
Respiratory Care
Vol. 56, Issue 3
1 Mar 2011
Use of Maximum End-Tidal CO2 Values to Improve End-Tidal CO2 Monitoring Accuracy
Fabrice Galia, Serge Brimioulle, Frederic Bonnier, Nicolas Vandenbergen, Michel Dojat, Jean-Louis Vincent, Laurent J Brochard
Respiratory Care Mar 2011, 56 (3) 278-283; DOI: 10.4187/respcare.00837